Cited by 440HIV Research and TreatmentT-cell and Retrovirus StudiesVirus-based gene therapy research

Predominant Mode of Human Immunodeficiency Virus Transfer between T Cells Is Mediated by Sustained Env-Dependent Neutralization-Resistant Virological Synapses

Open access
Chen, Ping, Hübner, Wolfgang, Spinelli, Matthew A., Chen, Benjamin K.·2007·Journal of Virology

Abstract

Cell-free human immunodeficiency virus type 1 (HIV-1) can initiate infections, but contact between infected and uninfected T cells can enhance viral spread through intercellular structures called virological synapses (VS). The relative contribution of VS to cell-free viral transfer has not been carefully measured. Using an ultrasensitive, fluorescent virus transfer assay, we estimate that when VS between HIV-expressing Jurkat T cells and primary CD4(+) T cells are formed, cell-associated transfer of virus is 18,000-fold more efficient than uptake of cell-free virus. Furthermore, in contrast to cell-free virus uptake, the VS deposits virus rapidly into focal, trypsin-resistant compartments in target T cells. This massive virus internalization requires Env-CD4 receptor interactions but is resistant to inhibition by patient-derived neutralizing antisera that inhibit homologous cell-free virus. Deleting the Env cytoplasmic tail does not abrogate VS-mediated transfer, but it renders the VS sensitive to neutralizing antibodies, suggesting that the tail limits exposure of VS-neutralizing epitopes on the surface of infected cells. Dynamic live imaging of the VS reveals that HIV-expressing cells are polarized and make sustained, Env-dependent contacts with target cells through uropod-like structures. The polarized T-cell morphology, Env-CD4 coordinated adhesion, and viral transfer from HIV-infected to uninfected cells suggest that VS allows HIV-1 to evade antibody neutralization and to disseminate efficiently. Future studies will discern to what extent this massive viral transfer contributes to productive infection or viral dissemination through the migration of virus-carrying T cells.

Integrity signals

Registry

Crossref · 10.1128/jvi.00381-07

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Measurement of viral fluorescence in target cells revealed cell-to-cell transmission is 18,000 times more efficient than infection with free virions.

    “Measurement of the viral fluorescence in target cells revealed that cell-to-cell transmission is 18,000 times more efficient than infection with free virions.”
  • According to the Chen et al. model, HIV-1 viral particles are internalized from the synaptic cleft into early endosomes of the target cell, where they undergo proteolytic maturation followed by fusion with the endosomal membrane.

    “According to the model of Chen et al. [29], HIV-1 viral particles are internalized from the synaptic cleft into the early endosomes of the target cell, where they undergo proteolytic maturation followed by fusion with the endosomal membrane [49,51,52].”

Cited by

Sorted by citations

Authors
Chen, P., Hübner, W., Spinelli, M. A., & Chen, B. K.
Affiliations
  • Icahn School of Medicine at Mount Sinai (US)
  • Department of Medicine, Division of Infectious Diseases, Immunology Institute, Mount Sinai School of Medicine, New York, New York 10029
Corresponding author
Chen, Benjamin K.
Venue
Journal of Virology
Published
2007-11-15
Volume
81
Issue
22
Pages
12582-12595
ISSN
  • 0022-538X (ISSN-L)
  • 1098-5514
OpenAlex
W2095703604
Cited by
440
References
0
Citations by year
2026: 10 · 2025: 9 · 2024: 10 · 2023: 14 · 2022: 25 · 2021: 23 · 2020: 25 · 2019: 18 · 2018: 20 · 2017: 22 · 2016: 26 · 2015: 24 · 2014: 37 · 2013: 42 · 2012: 27
FWCI
9.15
Type
journal article
Language
en
Open access
Locations
  • Journal of Virology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • PUB – Publications at Bielefeld University (Bielefeld University) (submittedVersion)
  • Publikationen an der Universität Bielefeld (Universität Bielefeld) (submittedVersion)
Funders
  • National Science Foundation
  • amfAR, The Foundation for AIDS Research
  • National Institutes of Health (1s10rr009145-01)
  • National Cancer Institute (CA095823, R24CA095823)
  • National Institute of Allergy and Infectious Diseases (AI-055321, K22AI055321)
  • National Center for Research Resources (RR-09145)
Topics
  • Life Sciences › Immunology and Microbiology › Virology › HIV Research and Treatment
  • Life Sciences › Immunology and Microbiology › Immunology › T-cell and Retrovirus Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Virus-based gene therapy research
Keywords
HIV-1, virological synapse, neutralizing antibodies, T cell polarization, CD4+ T cells, viral dissemination
MeSH terms
Antibodies, Viral, Cell Adhesion, Cytoskeleton, Humans, Immune Sera, Membrane Fusion, CD4-Positive T-Lymphocytes, HIV-1, Sequence Deletion, Jurkat Cells, Receptors, CCR5, Green Fluorescent Proteins, Virus Internalization, env Gene Products, Human Immunodeficiency Virus, gag Gene Products, Human Immunodeficiency Virus

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review