Application of Response Surface Methodology for Optimization of Conditions for Nickel Determination in Water and Vegetables by Switchable Solvent based Liquid Phase Microextraction
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A novel switchable-hydrophilicity solvent based liquid phase microextraction coupled with flame atomic absorption spectrometry has been applied for preconcentration and determination of Ni(II). Triethylamine (TEA) was selected as an inexpensive switchable solvent in the present work. Ni(II)-1-(2-pyridylazo)-2-naphthol complex was extracted into the TEA phase by converting the protonated carbonate to TEA. The experimental conditions were optimized using Plackett–Burman and Box–Behnken design methods. Such analytical parameters as the limit of detection, relative standard deviation and enhancement factor were 3 μg/L, 1.1% and 70, respectively. The calibration graph was linear over the range of 10 to 800 μg/L with the correlation coefficient of 0.998. The proposed method was successfully applied to the quantification of trace nickel in water and vegetable samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and evaluation of switchable-hydrophilicity solvents
Vanderveen, J. R., Durelle, J., & Jessop, P. G. (2014) · Green Chem. · doi:10.1039/c3gc42164c · Cited by 251
Tuzen, M., Soylak, M., Citak, D., Ferreira, H. S., Korn, M. G. A., & Bezerra, M. A. (2009) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.05.154 · Cited by 130
Cited by
Sustainable green solvents for microextraction techniques: Recent developments and applications
Carasek, E., Bernardi, G., Morelli, D., & Merib, J. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.461944 · Cited by 99
Switchable-hydrophilicity solvent liquid-liquid microextraction
Alshana, U., Hassan, M., Al-Nidawi, M., Yilmaz, E., & Soylak, M. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116025 · Cited by 90
Switchable hydrophilicity solvents in analytical chemistry. Five years of achievements
Bazel, Y., Rečlo, M., & Chubirka, Y. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105115 · Cited by 72
Pacheco-Fernández, I., González-Martín, R., e Silva, F. A., Freire, M. G., & Pino, V. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.08.022 · Cited by 69
“With regards to metal ions, Ni(II) [254,255,257,261], Co(II) [242,253,257,259], Cd(II) [245,248,257], Pd(II) [241,252], and Pb(II) [235,257] have been the most commonly determined in a wide variety of samples, including foods [235,242,248,253,254,257, 259,261,272,277] cigarettes [253,254], waters from different source…”
Background
Metadata
- Authors
- Heydari, F., & Ramezani, M.
- Venue
- Journal of Analytical Chemistry
- Publisher
- Pleiades Publishing Ltd
- Published
- 2019-11
- Volume
- 74
- Issue
- 11
- Pages
- 1081-1088
- ISSN
- 0021-8766 (ISSN-L)
- 1061-9348
- 1608-3199
- OpenAlex
- W2989146782
- Cited by
- 16
- References
- 2
- FWCI
- 1.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of Response Surface Methodology for Optimization of Conditions for Nickel Determination in Water and Vegetables by Switchable Solvent based Liquid Phase Microextraction. https://app.cochat.ai/papers/10.1134/s1061934819110054
- The paper
- Heydari, F., & Ramezani, M. (2019). Application of Response Surface Methodology for Optimization of Conditions for Nickel Determination in Water and Vegetables by Switchable Solvent based Liquid Phase Microextraction. Journal of Analytical Chemistry. https://doi.org/10.1134/s1061934819110054
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.