The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
A preconcentration system for determination of copper and nickel in water and food samples employing flame atomic absorption spectrometry
Open accessAbstract
A separation/preconcentration procedure using solid phase extraction has been proposed for the flame atomic absorption spectrometric determination of copper and nickel at trace level in food samples. The solid phase is Dowex Optipore SD-2 resin contained on a minicolumn, where analyte ions are sorbed as 5-methyl-4-(2-thiazolylazo) resorcinol chelates. After elution using 1 mol L(-1) nitric acid solution, the analytes are determinate employing flame atomic absorption spectrometry. The optimization step was performed using a full two-level factorial design and the variables studied were: pH, reagent concentration (RC) and amount of resin on the column (AR). Under the experimental conditions established in the optimization step, the procedure allows the determination of copper and nickel with limit of detection of 1.03 and 1.90 microg L(-1), respectively and precision of 7 and 8%, for concentrations of copper and nickel of 200 microg L(-1). The effect of matrix ions was also evaluated. The accuracy was confirmed by analyzing of the followings certified reference materials: NIST SRM 1515 Apple leaves and GBW 07603 Aquatic and Terrestrial Biological Products. The developed method was successfully applied for the determination of copper and nickel in real samples including human hair, chicken meat, black tea and canned fish.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The sample volume is an important factor for obtaining a high preconcentration factor.
“The sample volume is an important factor for obtaining a high preconcentration factor [51,52,53,54,55,56,57,58].”
From Deep Eutectic Solvent-Based Microextraction of Lead(II) Traces from Water and Aqueous Extracts before FAAS Measurements (2020) · cites this paper as [51]
Citations
Cites
Box-Behnken design: An alternative for the optimization of analytical methods
Ferreira, S. L. C., Bruns, R. E., Ferreira, H. S., Matos, G. D., David, J. M., Brandão, G. C., da Silva, E. G. P., Portugal, L. A., dos Reis, P. S., Souza, A. S., et al. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.07.011 · Cited by 3,214
Self-citationStatistical designs and response surface techniques for the optimization of chromatographic systems
Ferreira, S. L. C., Bruns, R. E., da Silva, E. G. P., dos Santos, W. N. L., Quintella, C. M. A. L. T. D. M. H., David, J. M., de Andrade, J. B., Breitkreitz, M. C., Jardim, I. C. S. F., & Neto, B. D. B. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.03.051 · Cited by 618
Ghaedi, M., Ahmadi, F., & Shokrollahi, A. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.08.012 · Cited by 604
Trace metal content in nine species of fish from the Black and Aegean Seas, Turkey
Uluözlü, Ö. D., Tüzen, M., Mendil, D., & Soylak, M. (2007) · Food Chemistry · doi:10.1016/j.foodchem.2007.01.003 · Cited by 295
Self-citationDetermination of trace element contents of baby foods from Turkey
Saraçoğlu, S., Saygı, K. Ö., Uluözlü, Ö. D., et al. (2006) · Food Chemistry · doi:10.1016/j.foodchem.2006.11.022 · Cited by 147
Element Composition of Tea Leaves and Tea Infusions and Its Impact on Health
Shen, F., & Chen, H. (2008) · Bulletin of Environmental Contamination and Toxicology · doi:10.1007/s00128-008-9367-z · Cited by 146
Cui, Y., Chang, X., Zhu, X., Luo, H., Hu, Z., Zou, X., & He, Q. (2007) · Microchemical Journal · doi:10.1016/j.microc.2007.04.004 · Cited by 134
Soylak, M., & Cay, R. S. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.12.005 · Cited by 126
Self-citationSoylak, M., Tüzen, M., Souza, A. S., et al. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.03.072 · Cited by 116
Self-citationGama, E. M., DASILVALIMA, A., & Lemos, V. A. (2006) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2006.01.015 · Cited by 106
Ensafi, A. A., & Shiraz, A. Z. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.05.001 · Cited by 95
Yamini, Y., Faraji, M., Shariati, S., Hassani, R., & Ghambarian, M. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.02.034 · Cited by 92
Zhu, X., Chang, X., Cui, Y., et al. (2007) · Microchemical Journal · doi:10.1016/j.microc.2007.03.002 · Cited by 87
Application of Multivariate Techniques in Optimization of Spectroanalytical Methods
Ferreira, S. L. C., Korn, M. D. G. A., Ferreira, H. S., et al. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551506 · Cited by 86
Self-citationSantos, W. L. D., SANTOS, C. M. M. D., Costa, J. L. O., Andrade, H. M. C., & Ferreira, S. L. C. (2004) · Microchemical Journal · doi:10.1016/j.microc.2004.02.006 · Cited by 85
Bezerra, M. A., Bruns, R. E., & Ferreira, S. L. C. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.07.056 · Cited by 76
Self-citationShokrollahi, A., Ghaedi, M., Gharaghani, S., et al. (2008) · Química Nova · doi:10.1590/s0100-40422008000100015 · Cited by 64
Ferreira, S. L. C. (2003) · Talanta · doi:10.1016/s0039-9140(03)00277-7 · Cited by 61
Ghaedi, M. (2006) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2006.02.055 · Cited by 58
Madrakian, T., Zolfigol, M. A., & Solgi, M. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.03.021 · Cited by 53
Lemos, V. A., Novaes, C. G., Lima, A. D. S., et al. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.11.039 · Cited by 52
Madrakian, T., & Ghazizadeh, F. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.09.013 · Cited by 52
Lemos, V. A., Bezerra, M. A., & Amorim, F. A. C. (2008) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2008.01.027 · Cited by 48
Self-citationKong, X., Jia, Q., & Zhou, W. (2007) · Microchemical Journal · doi:10.1016/j.microc.2007.06.006 · Cited by 46
Meesri, S., Praphairaksit, N., & Imyim, A. (2007) · Microchemical Journal · doi:10.1016/j.microc.2007.05.006 · Cited by 46
Tüzen, M., Narin, İ., Soylak, M., & Elçı, L. (2004) · Analytical Letters · doi:10.1081/al-120028620 · Cited by 36
Self-citationFerreira, H. S., dos Santos, W. N. L., Fiuza, R. P., et al. (2007) · Microchemical Journal · doi:10.1016/j.microc.2007.06.005 · Cited by 33
Self-citationSolid‐Phase Extraction of Silver in Geological Samples and its Determination by FAAS
Refiker, H., Merdıvan, M., & Aygün, R. S. (2008) · Separation Science and Technology · doi:10.1080/01496390701764833 · Cited by 26
Ghaedi, M., Amini, M. K., Rafi, A., et al. (2005) · Annali di Chimica · doi:10.1002/adic.200590052 · Cited by 24
dos Santos, W. N. L., Dias, F. D. S., Fernandes, M. S., et al. (2005) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b414502j · Cited by 22
Soylak, M., Çolak, H., Tüzen, M., et al. (2020) · Journal of Food and Drug Analysis · doi:10.38212/2224-6614.2500 · Cited by 18
Self-citationEnsafi, A. A. (2008) · Journal of the Korean Chemical Society · doi:10.5012/jkcs.2008.52.1.016 · Cited by 11
Ensafi, A. A., & Shiraz, A. Z. (2008) · Journal of the Brazilian Chemical Society · doi:10.1590/s0103-50532008000100003 · Cited by 11
Kruanetr, S., Tengjaroenkul, U., Liawruangrath, B., et al. (2007) · FIA Kenkyu Kondankai kaishi/Journal of flow injection analysis · Cited by 6
Flagged first, then by citations
Research works printed but not linked: 4
- Gundogdu, 2007, Simultaneous preconcentration of trace metals in environmental samples using Amberlite XAD-2010/8-Hydroxyquinoline System, Acta Chim. Slov., 54, 308
- Ahmadi, 2007, Micell-mediated extraction for preconcentration and determination of copper and zinc in real samples, Eurasian J. Anal. Chem., 2, 118
- Soylak, 2006, Comparison of digestion procedures for commercial powdered soup samples for the determination of their trace metal contents by AAS, J. Food Drug Anal., 14, 62
- Soylak, 1996, Determination of Some trace metal impurities in refined and unrefined salts after preconcentration onto activated carbon, Fresenius Environ. Bull., 5, 148
Cited by
Sorted by citations
Habila, M. A., AlMasoud, N., Alomar, T. S., AlOthman, Z. A., Yilmaz, E., & Soylak, M. (2020) · Molecules · doi:10.3390/molecules25204794 · Cited by 38
Self-citation
Metadata
- Authors
- Tuzen, M., Soylak, M., Citak, D., Ferreira, H. S., Korn, M. G. A., & Bezerra, M. A.
- Affiliations
- Erciyes University (TR)
- Universidade Federal da Bahia (BR)
- Southwest Bahia State University (BR)
- Corresponding author
- Soylak, Mustafa
- Venue
- Journal of Hazardous Materials
- Publisher
- Elsevier BV
- Published
- 2009-03
- Volume
- 162
- Issue
- 2-3
- Pages
- 1041-1045
- ISSN
- 0304-3894 (ISSN-L)
- OpenAlex
- W2051509939
- Cited by
- 130
- References
- 35
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 5 · 2023: 4 · 2022: 10 · 2021: 8 · 2020: 23 · 2019: 5 · 2018: 4 · 2017: 1 · 2016: 5 · 2015: 6 · 2014: 10 · 2013: 13 · 2012: 4
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- green
- www.rcaap.pt
- Licence
- Locations
- Journal of Hazardous Materials (publishedVersion)
- PubMed (publishedVersion)
- Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) (publishedVersion, other-oa)
- Funders
- Erciyes Üniversitesi
- Gaziosmanpasa Üniversitesi
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Physical Sciences › Environmental Science › Water Science and Technology › Environmental and Analytical Chemistry Studies
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- copper determination, nickel determination, solid-phase extraction, preconcentration, trace metal analysis, food samples, water samples, human hair, chicken meat, black tea, canned fish, matrix effects, two-level factorial designs
- MeSH terms
- Copper, Food Analysis, Hydrogen-Ion Concentration, Indicators and Reagents, Nickel, Spectrophotometry, Atomic, Water
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review