The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference
Open accessAbstract
Objective: To determine the accuracy of blood pressure (BP), capillary refill time (CRT), and central-peripheral temperature difference (CPTd) for detecting low upper body blood flow in the first day after birth. Methods: A prospective, two centre cohort study of 128 infants born at < 30 weeks gestation. Invasive BP (n = 108), CRT (n = 128), and CPTd (n = 46) were performed immediately before echocardiographic measurement of superior vena cava (SVC) flow at three, 5–10, and 24 hours after birth. Results: Forty four (34%) infants had low SVC flow (< 41 ml/kg/min) in the first day, 13/122 (11%) at three hours, 39/126 (31%) at 5–10 hours, and 4/119 (3%) at 24 hours. CPTd did not detect infants with low flows. Combining all observations in the first 24 hours, CRT ⩾ 3 seconds had 55% sensitivity and 81% specificity, mean BP < 30 mm Hg had 59% sensitivity and 77% specificity, and systolic BP < 40 mm Hg had 76% sensitivity and 68% specificity for detecting low SVC flow. Combining a mean BP < 30 mm Hg and/or central CRT ⩾ 3 seconds increases the sensitivity to 78%. Conclusions: Low upper body blood flow is common in the first day after birth and strongly associated with peri/intraventricular haemorrhage. BP and CRT are imperfect bedside tests for detecting low blood flow in the first day after birth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tibby, S. M., Hatherill, M., & Murdoch, I. A. (1999) · Archives of Disease in Childhood · doi:10.1136/adc.80.2.163 · Cited by 152
Cited by
Brierley, J., Carcillo, J. A., Choong, K., Cornell, T., DeCaen, A., Deymann, A., Doctor, A., Davis, A., Duff, J., Dugas, M.-A., et al. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819323c6 · Cited by 1,073
Davis, A. L., Carcillo, J. A., Aneja, R. K., Deymann, A. J., Lin, J. C., Nguyen, T. C., Okhuysen-Cawley, R. S., Relvas, M. S., Rozenfeld, R. A., Skippen, P. W., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002425 · Cited by 670
Clinical monitoring of systemic hemodynamics in critically ill newborns
de Boode, W.-P. (2010) · Early Human Development · doi:10.1016/j.earlhumdev.2010.01.031 · Cited by 87
Capillary refill time and cardiac output in children undergoing cardiac catheterization *
Lobos, A.-T., Lee, S., & Menon, K. (2012) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0b013e318220afdc · Cited by 33
Targeted Neonatal Echocardiography in Patients With Hemodynamic Instability
Rahde Bischoff, A., Bhombal, S., Altman, C. A., Fraga, M. V., Punn, R., Rohatgi, R. K., Lopez, L., & McNamara, P. J. (2022) · PEDIATRICS · doi:10.1542/peds.2022-056415i · Cited by 21
Metadata
- Authors
- Osborn, D. A., Evans, N., & Kluckow, M.
- Venue
- Archives of Disease in Childhood - Fetal and Neonatal Edition
- Publisher
- BMJ
- Published
- 2004-03
- Volume
- 89
- Issue
- 2
- Pages
- F168-F173
- ISSN
- 1359-2998 (ISSN-L)
- 1468-2052
- OpenAlex
- W2171348189
- Cited by
- 194
- References
- 1
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference. https://app.cochat.ai/papers/10.1136/adc.2002.023796
- The paper
- Osborn, D. A., Evans, N., & Kluckow, M. (2004). Clinical detection of low upper body blood flow in very premature infants using blood pressure, capillary refill time, and central-peripheral temperature difference. Archives of Disease in Childhood - Fetal and Neonatal Edition. https://doi.org/10.1136/adc.2002.023796
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.