Incidence of nasal trauma associated with nasal prong versus nasal mask during continuous positive airway pressure treatment in very low birthweight infants: a randomised control study
Open accessAbstract
Objective: To compare the incidence of nasal trauma associated with the use of prong or mask during nasal continuous positive airway pressure (nCPAP) support in very low birthweight (<1501 g) infants. Design: Randomised controlled clinical trial. Setting: Tertiary care university hospital, Department of Paediatrics, Kuala Lumpur, Malaysia. Methods: All very low birthweight infants admitted to the neonatal intensive care unit between July 2001 and December 2003 who received nCPAP through the Infant Flow Driver were randomised to the use of either nasal prong or mask. The nasal cavity of these infants was inspected daily during the first week and then weekly until they were weaned off nCPAP. Results: Of the 89 infants recruited, 41 were randomised to the mask group and 48 to the prong group. There was no significant difference in the incidence of nasal trauma between the two groups (p = 0.5). The primary site of trauma was at the junction between the nasal septum and the philtrum in infants in the mask group and the walls of the nasal septum in the prong group. Logistic regression analysis showed that duration of nCPAP was the only significant risk factor associated with development of nasal injury, after birth weight, gestational age, and nasal device used had been controlled for (adjusted odds ratio 1.04; 95% confidence interval 1.01 to 1.07; p = 0.003). Conclusion: Irrespective of the type of nasal device used, nasal trauma is common during nCPAP treatment, which should therefore be terminated as soon as possible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
High Flow Nasal Cannulae Therapy in Infants with Bronchiolitis
McKiernan, C., Chua, L. C., Visintainer, P. F., & Allen, H. (2010) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2009.10.039 · Cited by 302
De Paoli, A. G., Davis, P. G., Argus, B., & Jackson, H. D. (2008) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd002977.pub2 · Cited by 298
Efficacy and safety of CPAP in low-and middle-income countries
Thukral, A., Sankar, M. J., Chandrasekaran, A., Agarwal, R., & Paul, V. K. (2016) · Journal of Perinatology · doi:10.1038/jp.2016.29 · Cited by 114
Pressure Ulcers in the Hospitalized Neonate: Rates and Risk Factors
Visscher, M., & Taylor, T. (2014) · Scientific Reports · doi:10.1038/srep07429 · Cited by 104
Iatrogenic skin injury in the neonatal intensive care unit
Sardesai, S. R., Kornacka, M. K., Walas, W., & Ramanathan, R. (2011) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767051003728245 · Cited by 73
Metadata
- Authors
- Yong, S.-C., Chen, S.-J., & Boo, N.-Y.
- Venue
- Archives of Disease in Childhood - Fetal and Neonatal Edition
- Publisher
- BMJ
- Published
- 2005-06-07
- Volume
- 90
- Issue
- 6
- Pages
- F480-F483
- ISSN
- 1359-2998 (ISSN-L)
- 1468-2052
- OpenAlex
- W1999694831
- Cited by
- 187
- References
- 0
- FWCI
- 5.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incidence of nasal trauma associated with nasal prong versus nasal mask during continuous positive airway pressure treatment in very low birthweight infants: a randomised control study. https://app.cochat.ai/papers/10.1136/adc.2004.069351
- The paper
- Yong, S.-C., Chen, S.-J., & Boo, N.-Y. (2005). Incidence of nasal trauma associated with nasal prong versus nasal mask during continuous positive airway pressure treatment in very low birthweight infants: a randomised control study. Archives of Disease in Childhood - Fetal and Neonatal Edition. https://doi.org/10.1136/adc.2004.069351
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.