Making electronic prescribing alerts more effective: scenario-based experimental study in junior doctors
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Expert authorities recommend clinical decision support systems to reduce prescribing error rates, yet large numbers of insignificant on-screen alerts presented in modal dialog boxes persistently interrupt clinicians, limiting the effectiveness of these systems. This study compared the impact of modal and non-modal electronic (e-) prescribing alerts on prescribing error rates, to help inform the design of clinical decision support systems. DESIGN: A randomized study of 24 junior doctors each performing 30 simulated prescribing tasks in random order with a prototype e-prescribing system. Using a within-participant design, doctors were randomized to be shown one of three types of e-prescribing alert (modal, non-modal, no alert) during each prescribing task. MEASUREMENTS: The main outcome measure was prescribing error rate. Structured interviews were performed to elicit participants' preferences for the prescribing alerts and their views on clinical decision support systems. RESULTS: Participants exposed to modal alerts were 11.6 times less likely to make a prescribing error than those not shown an alert (OR 11.56, 95% CI 6.00 to 22.26). Those shown a non-modal alert were 3.2 times less likely to make a prescribing error (OR 3.18, 95% CI 1.91 to 5.30) than those not shown an alert. The error rate with non-modal alerts was 3.6 times higher than with modal alerts (95% CI 1.88 to 7.04). CONCLUSIONS: Both kinds of e-prescribing alerts significantly reduced prescribing error rates, but modal alerts were over three times more effective than non-modal alerts. This study provides new evidence about the relative effects of modal and non-modal alerts on prescribing outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Garg, A. X., Adhikari, N. K. J., McDonald, H., Rosas-Arellano, M. P., Devereaux, P. J., Beyene, J., Sam, J., & Haynes, R. B. (2005) · JAMA · doi:10.1001/jama.293.10.1223 · Cited by 2,936
The Impact of Computerized Physician Order Entry on Medication Error Prevention
Bates, D. W., Teich, J. M., Lee, J., Seger, D., Kuperman, G. J., Ma'Luf, N., Boyle, D., & Leape, L. (1999) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.1999.00660313 · Cited by 1,260 · cited 2×
“Experience in the USA has shown that e-prescribing has the potential to reduce the rate of serious medication errors by up to 81%.(6) In the UK, the use of computers in prescribing is well established in primary care, whereas e-prescribing in hospitals is limited to a small number of sites.”
BackgroundOverriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117 · cited 1×
“Despite the benefits they may bring to clinical practice, there is wide variability in the adoption of recommendations generated by CDS systems, with up to 96% of alerts being overridden or ignored.(12) A systematic review has identified a range of factors that adversely affect the utilization of CDS, including unsuit…”
BackgroundMedication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763
Physicians' Decisions to Override Computerized Drug Alerts in Primary Care
Weingart, S. N., Toth, M., Sands, D. Z., Aronson, M. D., Davis, R. B., & Phillips, R. S. (2003) · Archives of Internal Medicine · doi:10.1001/archinte.163.21.2625 · Cited by 487
Trafton, J. G., Altmann, E. M., Brock, D. P., & Mintz, F. E. (2003) · International Journal of Human-Computer Studies · doi:10.1016/s1071-5819(03)00023-5 · Cited by 457
Improving Acceptance of Computerized Prescribing Alerts in Ambulatory Care
Shah, N. R., Seger, A. C., Seger, D. L., Fiskio, J. M., Kuperman, G. J., Blumenfeld, B., Recklet, E. G., Bates, D. W., & Gandhi, T. K. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1868 · Cited by 353 · cited 1×
“Several authors have highlighted the limitations of bespoke datasets and the lack of a widely available repository for research and commercial applications.(19) 22 25 Second, our e-prescribing software was not based on a commercial system, but its design was informed by expert opinion.”
MethodComputerized clinical decision support for prescribing: provision does not guarantee uptake
Moxey, A., Robertson, J., Newby, D., Hains, I., Williamson, M., & Pearson, S.-A. (2010) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m3170 · Cited by 305 · cited 2×
“Tailoring the degree of prescribing workflow disruption according to the severity of the alert, so that the most appropriate warning mechanism can be used, may improve the effectiveness of CDS systems.(13) 19 22 24 25 However, although minimizing the workflow disruption caused by low-severity alerts may reduce alert f…”
BackgroundSchedlbauer, A., Prasad, V., Mulvaney, C., Phansalkar, S., Stanton, W., Bates, D. W., & Avery, A. J. (2009) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2910 · Cited by 262 · cited 1×
“Although the relevance and utility of CDS alerts may be increased by improvements in data quality and decision support logic, little is known about which user interface design features of alerts are associated with an impact on prescribing errors, and there are few empiric studies assessing the effectiveness of differ…”
BackgroundPhansalkar, S., Edworthy, J., Hellier, E., Seger, D. L., Schedlbauer, A., Avery, A. J., & Bates, D. W. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2010.005264 · Cited by 226 · cited 2×
“There is substantial evidence from areas other than e-prescribing research that attention to both design and language of warnings can have a large effect on the effectiveness of communication.(25) 39 We are now investigating whether graphical warning symbols included in alerts can reduce the difference in outcomes fou…”
Background
Cited by
Roshanov, P. S., Fernandes, N., Wilczynski, J. M., Hemens, B. J., You, J. J., Handler, S. M., Nieuwlaat, R., Souza, N. M., Beyene, J., Spall, H. G. C. V., et al. (2013) · BMJ · doi:10.1136/bmj.f657 · Cited by 456
Taheri Moghadam, S., Sadoughi, F., Velayati, F., Ehsanzadeh, S. J., & Poursharif, S. (2021) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-020-01376-8 · Cited by 136
Wyatt, J. C. (2018) · BMC Medicine · doi:10.1186/s12916-018-1211-7 · Cited by 61
Self-citationBell, H., Garfield, S., Khosla, S., Patel, C., & Franklin, B. D. (2019) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2017-001483 · Cited by 29
“9 In addition, alerts may have a negative impact on prescribers’ knowledge 13 and concerns have been raised about inexperienced doctors becoming too dependent on CDS. 14 The majority of the research in this field has been conducted outside the UK, and may not be gener-alisable to the UK due to…”
Influential
Metadata
- Authors
- Scott, G. P. T., Shah, P., Wyatt, J. C., Makubate, B., & Cross, F. W.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-11
- Volume
- 18
- Issue
- 6
- Pages
- 789-798
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2155682868
- Cited by
- 61
- References
- 11
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.