Using statistical and machine learning to help institutions detect suspicious access to electronic health records
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To determine whether statistical and machine-learning methods, when applied to electronic health record (EHR) access data, could help identify suspicious (ie, potentially inappropriate) access to EHRs. METHODS: From EHR access logs and other organizational data collected over a 2-month period, the authors extracted 26 features likely to be useful in detecting suspicious accesses. Selected events were marked as either suspicious or appropriate by privacy officers, and served as the gold standard set for model evaluation. The authors trained logistic regression (LR) and support vector machine (SVM) models on 10-fold cross-validation sets of 1291 labeled events. The authors evaluated the sensitivity of final models on an external set of 58 events that were identified as truly inappropriate and investigated independently from this study using standard operating procedures. RESULTS: The area under the receiver operating characteristic curve of the models on the whole data set of 1291 events was 0.91 for LR, and 0.95 for SVM. The sensitivity of the baseline model on this set was 0.8. When the final models were evaluated on the set of 58 investigated events, all of which were determined as truly inappropriate, the sensitivity was 0 for the baseline method, 0.76 for LR, and 0.79 for SVM. LIMITATIONS: The LR and SVM models may not generalize because of interinstitutional differences in organizational structures, applications, and workflows. Nevertheless, our approach for constructing the models using statistical and machine-learning techniques can be generalized. An important limitation is the relatively small sample used for the training set due to the effort required for its construction. CONCLUSION: The results suggest that statistical and machine-learning methods can play an important role in helping privacy officers detect suspicious accesses to EHRs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Security and privacy in electronic health records: a systematic literature review.
Fernández-Alemán, J. L., Señor, I. C., Lozoya, P. Á. O., & Toval, A. (2013) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2012.12.003 · Cited by 675
Tai-Seale, M., Olson, C. W., Li, J., Chan, A. S., Morikawa, C., Durbin, M., Wang, W., & Luft, H. S. (2017) · Health Affairs · doi:10.1377/hlthaff.2016.0811 · Cited by 379
Security and Privacy in the Medical Internet of Things: A Review
Sun, W., Cai, Z., Li, Y., Liu, F., Fang, S., & Wang, G. (2018) · Security and Communication Networks · doi:10.1155/2018/5978636 · Cited by 289
Clinical Decision Support: a 25 Year Retrospective and a 25 Year Vision
Sittig, D. F., Wright, A., & Middleton, B. (2016) · Yearbook of Medical Informatics · doi:10.15265/iys-2016-s034 · Cited by 277
“Big Data” and the Electronic Health Record
Ross, M. K., Wei, W., & Ohno-Machado, L. (2014) · Yearbook of Medical Informatics · doi:10.15265/iy-2014-0003 · Cited by 190
“In addition to role-based access control for EHRs, audit systems to detect unauthorized and suspicious accesses have already been successfully implemented, such as the machine-learning model to detect suspicious accesses to EHR data [118].”
MethodSelf-citationSurvey of Machine Learning based intrusion detection methods for Internet of Medical Things
Si-Ahmed, A., Al-Garadi, M. A., & Boustia, N. (2023) · Applied Soft Computing · doi:10.1016/j.asoc.2023.110227 · Cited by 177
Rule, A., Chiang, M. F., & Hribar, M. R. (2020) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocz196 · Cited by 136
Meeks, D. W., Takian, A., Sittig, D. F., Singh, H., & Barber, N. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-001762 · Cited by 91
Clinical research informatics: a conceptual perspective
Kahn, M. G., & Weng, C. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-000968 · Cited by 40
Amroze, A., Field, T. S., Fouayzi, H., Sundaresan, D., Burns, L., Garber, L., Sadasivam, R. S., Mazor, K. M., Gurwitz, J. H., & Cutrona, S. L. (2019) · JMIR Medical Informatics · doi:10.2196/12650 · Cited by 25
Cutrona, S. L., Fouayzi, H., Burns, L., Sadasivam, R. S., Mazor, K. M., Gurwitz, J. H., Garber, L., Sundaresan, D., Houston, T. K., & Field, T. S. (2017) · Journal of General Internal Medicine · doi:10.1007/s11606-017-4146-3 · Cited by 24
Metadata
- Authors
- Boxwala, A. A., Kim, J., Grillo, J. M., & Ohno-Machado, L.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-07
- Volume
- 18
- Issue
- 4
- Pages
- 498-505
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2097712921
- Cited by
- 82
- References
- 0
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.