CoChat

Computer-aided diagnosis of pneumonia in patients with chronic obstructive pulmonary disease

Open access
Sanchez Morillo, D., Leon Jimenez, A., Moreno, S. A. · 2013 · Journal of the American Medical Informatics Association
Cited by 69

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Early diagnosis of pneumonia and discrimination between this disease and chronic obstructive pulmonary disease (COPD) exacerbations in patients with COPD are crucial for optimal clinical management and treatment. OBJECTIVES: To examine the use of computerized analysis of respiratory sounds, a hybrid system based on principal component analysis (PCA) and probabilistic neural networks (PNNs), to aid the detection of coexisting pneumonia in patients with COPD. METHODS AND MATERIALS: A convenience sample of 58 patients with COPD (25 patients hospitalized for community-acquired pneumonia and 33 owing to acute exacerbation of COPD) was studied. Auscultations were performed by the patients themselves on their suprasternal notch. Short-time Fourier transform analysis was used to extract features from the recorded respiratory sounds, PCA was selected for dimensionality reduction and a PNN was trained as classifier. 10-Fold cross-validation and receiver operating characteristic curve analysis were used to estimate the system performance. RESULTS: Based on the cross-validation results, a sensitivity and a specificity of 72% and 81.8%, respectively, were achieved in validation data. The operating point was selected to maximize the specificity and sensitivity pair in the training set. DISCUSSION: The results strongly suggest that electronic self-auscultation at a single location (suprasternal notch) can support diagnosis of pneumonia in patients with COPD. CONCLUSIONS: A simple, cost-effective method has been proposed to aid decision-making in areas with no radiological facilities available and in resource-constrained settings, and could have a great diagnostic impact on telemedicine applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2012-001171

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 69

Metadata

Authors
Sanchez Morillo, D., Leon Jimenez, A., & Moreno, S. A.
Venue
Journal of the American Medical Informatics Association
Published
2013-06-01
Volume
20
Issue
e1
Pages
e111-e117
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W55501266
Cited by
69
References
3
FWCI
2.19
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computer-aided diagnosis of pneumonia in patients with chronic obstructive pulmonary disease. https://app.cochat.ai/papers/10.1136/amiajnl-2012-001171
The paper
Sanchez Morillo, D., Leon Jimenez, A., & Moreno, S. A. (2013). Computer-aided diagnosis of pneumonia in patients with chronic obstructive pulmonary disease. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2012-001171

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.