Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 318

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Reduction in medication errors in hospitals due to adoption of computerized provider order entry systems

Open access
Radley, D. C., Wasserman, M. R., Olsho, L. E., Shoemaker, S. J., Spranca, M. D., Bradshaw, B. · 2013 · Journal of the American Medical Informatics Association

Abstract

OBJECTIVE: Medication errors in hospitals are common, expensive, and sometimes harmful to patients. This study's objective was to derive a nationally representative estimate of medication error reduction in hospitals attributable to electronic prescribing through computerized provider order entry (CPOE) systems. MATERIALS AND METHODS: We conducted a systematic literature review and applied random-effects meta-analytic techniques to derive a summary estimate of the effect of CPOE on medication errors. This pooled estimate was combined with data from the 2006 American Society of Health-System Pharmacists Annual Survey, the 2007 American Hospital Association Annual Survey, and the latter's 2008 Electronic Health Record Adoption Database supplement to estimate the percentage and absolute reduction in medication errors attributable to CPOE. RESULTS: Processing a prescription drug order through a CPOE system decreases the likelihood of error on that order by 48% (95% CI 41% to 55%). Given this effect size, and the degree of CPOE adoption and use in hospitals in 2008, we estimate a 12.5% reduction in medication errors, or ∼17.4 million medication errors averted in the USA in 1 year. DISCUSSION: Our findings suggest that CPOE can substantially reduce the frequency of medication errors in inpatient acute-care settings; however, it is unclear whether this translates into reduced harm for patients. CONCLUSIONS: Despite CPOE systems' effectiveness at preventing medication errors, adoption and use in US hospitals remain modest. Current policies to increase CPOE adoption and use will likely prevent millions of additional medication errors each year. Further research is needed to better characterize links to patient harm.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2012-001241

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 30 references

Cited by

See all 318

Metadata

Authors
Radley, D. C., Wasserman, M. R., Olsho, L. E., Shoemaker, S. J., Spranca, M. D., & Bradshaw, B.
Venue
Journal of the American Medical Informatics Association
Published
2013-05-01
Volume
20
Issue
3
Pages
470-476
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2153483129
Cited by
318
References
30
FWCI
58.71
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reduction in medication errors in hospitals due to adoption of computerized provider order entry systems. https://app.cochat.ai/papers/10.1136/amiajnl-2012-001241
The paper
Radley, D. C., Wasserman, M. R., Olsho, L. E., Shoemaker, S. J., Spranca, M. D., & Bradshaw, B. (2013). Reduction in medication errors in hospitals due to adoption of computerized provider order entry systems. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2012-001241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.