Cited by 12Cardiac pacing and defibrillation studiesInfective Endocarditis Diagnosis and ManagementCardiac tumors and thrombi

Pacemaker lead-associated thrombosis in cardiac resynchronisation therapy

Open access
Buttigieg, Jesmar, Asciak, Rachelle, Mallia Azzopardi, Charles·2015·BMJ Case Reports

Abstract

Pacemaker lead-associated thrombosis is a possible complication of any cardiac implantable electronic device. We present a case of a middle-aged woman with a history of ischaemic left ventricular failure, who presented with fever and other non-specific symptoms 4 months after cardiac resynchronisation therapy. A transoesophageal echocardiogram confirmed a vegetation-like structure originating from the pacemaker lead in the right atrium. The patient was treated with intravenous antibiotics followed by open heart surgery in order to remove this mass as well as the pacing device, including all three pacing leads. Histology and culture of the retrieved mass confirmed a sterile thrombus with no features to suggest an infected mass (vegetation). The patient made an uncomplicated recovery and there were no long-term sequelae on follow-up during the 2 years after the event.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bcr-2015-210314

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Fabijanić D, Giunio L, Vujičić M, et al. Right atrial pacemaker lead thrombosis incidentally detected by transesophageal echocardiography. Coll Antropol 2005;29:159-61.

Cited by

Sorted by citations

Authors
Buttigieg, J., Asciak, R., & Mallia Azzopardi, C.
Affiliations
  • Mater Dei Hospital (MT)
  • Department of Internal Medicine and Infectious Diseases Medicine, Mater Dei Hospital, Msida, Malta
Corresponding author
Asciak, Rachelle
Venue
BMJ Case Reports
Publisher
BMJ
Published
2015-07-07
Volume
2015
Pages
bcr2015210314
ISSN
1757-790X (ISSN-L)
OpenAlex
W1802341058
Cited by
12
References
22
Citations by year
2026: 1 · 2024: 1 · 2023: 2 · 2022: 1 · 2021: 2 · 2020: 1 · 2019: 3 · 2018: 1
FWCI
0.24
Type
journal article
Language
en
Open access
Locations
  • BMJ Case Reports (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
  • Health Sciences › Medicine › Epidemiology › Infective Endocarditis Diagnosis and Management
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac tumors and thrombi
Keywords
cardiac resynchronization therapy, cardiac implantable electronic devices, right atrium, transesophageal echocardiography, antibiotic therapy
MeSH terms
Anti-Bacterial Agents, Female, Fever, Heart Atria, Humans, Middle Aged, Pacemaker, Artificial, Thrombosis, Treatment Outcome, Defibrillators, Implantable, Echocardiography, Transesophageal, Cardiac Resynchronization Therapy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review