The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
ICGA-GPT: report generation and question answering for indocyanine green angiography images
Abstract
Background: Indocyanine green angiography (ICGA) is vital for diagnosing chorioretinal diseases, but its interpretation and patient communication require extensive expertise and time-consuming efforts. We aim to develop a bilingual ICGA report generation and question-answering (QA) system. Methods: Our dataset comprised 213 129 ICGA images from 2919 participants. The system comprised two stages: image–text alignment for report generation by a multimodal transformer architecture, and large language model (LLM)-based QA with ICGA text reports and human-input questions. Performance was assessed using both qualitative metrics (including Bilingual Evaluation Understudy (BLEU), Consensus-based Image Description Evaluation (CIDEr), Recall-Oriented Understudy for Gisting Evaluation-Longest Common Subsequence (ROUGE-L), Semantic Propositional Image Caption Evaluation (SPICE), accuracy, sensitivity, specificity, precision and F1 score) and subjective evaluation by three experienced ophthalmologists using 5-point scales (5 refers to high quality). Results: We produced 8757 ICGA reports covering 39 disease-related conditions after bilingual translation (66.7% English, 33.3% Chinese). The ICGA-GPT model’s report generation performance was evaluated with BLEU scores (1–4) of 0.48, 0.44, 0.40 and 0.37; CIDEr of 0.82; ROUGE of 0.41 and SPICE of 0.18. For disease-based metrics, the average specificity, accuracy, precision, sensitivity and F1 score were 0.98, 0.94, 0.70, 0.68 and 0.64, respectively. Assessing the quality of 50 images (100 reports), three ophthalmologists achieved substantial agreement (kappa=0.723 for completeness, kappa=0.738 for accuracy), yielding scores from 3.20 to 3.55. In an interactive QA scenario involving 100 generated answers, the ophthalmologists provided scores of 4.24, 4.22 and 4.10, displaying good consistency (kappa=0.779). Conclusion: This pioneering study introduces the ICGA-GPT model for report generation and interactive QA for the first time, underscoring the potential of LLMs in assisting with automated ICGA image interpretation.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
BERT: Pre-training of Deep Bidirectional Transformers for Language Understanding
Devlin, J., Chang, M.-W., Lee, K., & Toutanova, K. (2018) · arXiv · doi:10.48550/arxiv.1810.04805 · Cited by 73,173
An Image is Worth 16x16 Words: Transformers for Image Recognition at Scale
Dosovitskiy, A., Beyer, L., Kolesnikov, A., Weissenborn, D., Zhai, X., Unterthiner, T., Dehghani, M., Minderer, M., Heigold, G., Gelly, S., et al. (2020) · arXiv · doi:10.48550/arxiv.2010.11929 · Cited by 47,472
BLEU: a method for automatic evaluation of machine translation
Papineni, K., Roukos, S., Ward, T., & Zhu, W.-J. (2001) · Proceedings of the 40th Annual Meeting on Association for Computational Linguistics - ACL '02 · doi:10.3115/1073083.1073135 · Cited by 21,344
CIDEr: Consensus-based image description evaluation
Vedantam, R., Zitnick, C. L., & Parikh, D. (2015) · 2015 IEEE Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2015.7299087 · Cited by 4,845
Large language models encode clinical knowledge
Singhal, K., Azizi, S., Tu, T., Mahdavi, S. S., Wei, J., Chung, H. W., Scales, N., Tanwani, A., Cole-Lewis, H., Pfohl, S., et al. (2023) · Nature · doi:10.1038/s41586-023-06291-2 · Cited by 4,083
Large Language Models Encode Clinical Knowledge
Singhal, K., Azizi, S., Tu, T., Mahdavi, S. S., Wei, J., Chung, H. W., Scales, N., Tanwani, A., Cole-Lewis, H., Pfohl, S., et al. (2022) · arXiv · doi:10.48550/arxiv.2212.13138 · Cited by 4,083
Collins, G. S., Reitsma, J. B., Altman, D. G., & Moons, K. G. M. (2015) · British Journal of Cancer · doi:10.1038/bjc.2014.639 · Cited by 3,293
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212
Llama 2: Open Foundation and Fine-Tuned Chat Models
Touvron, H., Martin, L., Stone, K., Albert, P., Almahairi, A., Babaei, Y., Bashlykov, N., Batra, S., Bhargava, P., Bhosale, S., et al. (2023) · arXiv · doi:10.48550/arxiv.2307.09288 · Cited by 2,604
Self-citationA Survey of Large Language Models
Zhao, W. X., Zhou, K., Li, J., Tang, T., Dong, Z., Hou, Y., Zhang, B., Min, Y., Zhang, J., Liu, P., et al. (2026) · Frontiers of Computer Science · doi:10.1007/s11704-026-60308-3 · Cited by 2,093
Research works printed but not linked: 1
- Lin C-Y . n.d. ROUGE: a package for automatic evaluation of summaries. Text Summarization Branches Out;2004:74–81.
Cited by
Large language models in patient education: a scoping review of applications in medicine
Aydin, S., Karabacak, M., Vlachos, V., & Margetis, K. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1477898 · Cited by 288
Large language models for disease diagnosis: a scoping review
Zhou, S., Xu, Z., Zhang, M., Xu, C., Guo, Y., Zhan, Z., Fang, Y., Ding, S., Wang, J., Xu, K., et al. (2025) · npj Artificial Intelligence · doi:10.1038/s44387-025-00011-z · Cited by 193
Evaluating large language models and agents in healthcare: key challenges in clinical applications
Chen, X., Xiang, J., Lu, S., Liu, Y., He, M., & Shi, D. (2025) · Intelligent Medicine · doi:10.1016/j.imed.2025.03.002 · Cited by 136
Self-citationA multimodal visual–language foundation model for computational ophthalmology
Shi, D., Zhang, W., Yang, J., Huang, S., Chen, X., Xu, P., Jin, K., Lin, S. C., Wei, J., Yusufu, M., et al. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01772-2 · Cited by 132
Self-citationXu, P., Chen, X., Zhao, Z., & Shi, D. (2024) · British Journal of Ophthalmology · doi:10.1136/bjo-2023-325054 · Cited by 63
Self-citation
Metadata
- Authors
- Chen, X., Zhang, W., Zhao, Z., Xu, P., Zheng, Y., Shi, D., & He, M.
- Affiliations
- Hong Kong Polytechnic University (HK)
- State Key Laboratory of Ophthalmology (CN)
- Corresponding author
- Shi, Danli
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2024-03-20
- Volume
- 108
- Issue
- 10
- Pages
- 1450-1456
- ISSN
- 0007-1161 (ISSN-L)
- 1468-2079
- OpenAlex
- W4392984569
- Cited by
- 36
- References
- 32
- Citations by year
- 2026: 3 · 2025: 24 · 2024: 9
- FWCI
- 5.01
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
- Minerva Access (University of Melbourne) (submittedVersion)
- Funders
- Start-up Fund for RAPs under the Strategic Hiring Scheme (P0048623)
- Global STEM Professorship Scheme from HKSAR (P0046113)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Multimodal Machine Learning Applications
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
- Keywords
- report generation, question answering, indocyanine green angiography, large language models, multimodal transformer, bilingual translation, chorioretinal diseases, automated medical report generation, patient communication
- MeSH terms
- Aged, Coloring Agents, Female, Fluorescein Angiography, Fundus Oculi, Humans, Indocyanine Green, Male, Middle Aged, Retinal Diseases, Reproducibility of Results, Choroid Diseases
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ICGA-GPT: report generation and question answering for indocyanine green angiography images. https://app.cochat.ai/papers/10.1136/bjo-2023-324446
- The paper
- Chen, X., Zhang, W., Zhao, Z., Xu, P., Zheng, Y., Shi, D., & He, M. (2024). ICGA-GPT: report generation and question answering for indocyanine green angiography images. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2023-324446
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.