Effect of mydriasis and different field strategies on digital image screening of diabetic eye disease
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIMS: To assess the effects of (1) mydriasis and (2) single versus three field photography on screening for diabetic eye disease using digital photography METHOD: Slit lamp examination findings were compared to digital fundal photographs for the detection of any retinopathy and for referable retinopathy in 398 patients (794 eyes). A Topcon TRC-NW6S digital non-mydriatic fundus camera was used. Three photographic strategies were used: undilated single field, dilated single field, and dilated multiple fields. The photographs were presented in random order to one of two retinal screeners. For the single field photographs the screeners were masked to the use of mydriatics. In 13% of fundal photographs, grading was performed by both, rather than just one grader. RESULTS: Mydriasis reduced the proportion of ungradable photographs from 26% to 5% (p<0.001). Neither mydriasis nor three field photography improved the sensitivity or specificity for the detection of any retinopathy or of referable retinopathy when compared with undilated single field photography. The sensitivity and specificity for detecting referable retinopathy using undilated single field photography was 77% (95% CI 71 to 84) and 95 % (95% CI 93 to 97) respectively. Using dilated single field photography the figures were 81% (95% CI 76 to 87) and 92% (95% CI 90 to 94) respectively. Using dilated three field photography the figures were 83% (95% CI 78 to 88) and 93% (95% CI 91 to 96) respectively. Intergrader reliability for the detection of referable retinopathy in gradable photographs was excellent (Kappa values 0.86-1.00). CONCLUSIONS: Mydriasis reduces the technical failure rate. Mydriasis and the three field photography as used in this study do not increase the sensitivity or specificity of detecting diabetic retinopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How Effective Are Treatments for Diabetic Retinopathy?
Ferris, F. L. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03500100088034 · Cited by 392
Mydriasis and glaucoma: exploding the myth. A systematic review
Pandit, R. J., & Taylor, R. (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00368.x · Cited by 94
Cited by
Microvascular and macrovascular complications in children and adolescents
Donaghue, K. C., Wadwa, R. P., Dimeglio, L. A., Wong, T. Y., Chiarelli, F., Marcovecchio, M. L., Salem, M., Raza, J., Hofman, P. L., & Craig, M. E. (2014) · Pediatric Diabetes · doi:10.1111/pedi.12180 · Cited by 181
“Fundal photography provides a validated result that can be useful for monitoring clinical quality and in research, but photographs may not be gradable in which case ophthalmoscopy needs to be performed; mydriasis can reduce the technical failure rate (55).”
Retinal Imaging Techniques for Diabetic Retinopathy Screening
Goh, J. K. H., Cheung, C. Y., Sim, S. S., Tan, P. C., Tan, G. S. W., & Wong, T. Y. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816629491 · Cited by 174
Validation of Smartphone Based Retinal Photography for Diabetic Retinopathy Screening
Rajalakshmi, R., Arulmalar, S., Usha, M., Prathiba, V., Kareemuddin, K. S., Anjana, R. M., & Mohan, V. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138285 · Cited by 173
“Murgatroyd et al evaluated DR screening with a non-mydriatic camera and found that mydriasis was found to reduce the proportion of ungradable photographs from 26% to 5% [25].”
BackgroundQatar Biobank Cohort Study: Study Design and First Results
Al Thani, A., Fthenou, E., Paparrodopoulos, S., Al Marri, A., Shi, Z., Qafoud, F., & Afifi, N. (2019) · American Journal of Epidemiology · doi:10.1093/aje/kwz084 · Cited by 170
The Qatar Biobank: background and methods
Al Kuwari, H., Al Thani, A., Al Marri, A., Al Kaabi, A., Abderrahim, H., Afifi, N., Qafoud, F., Chan, Q., Tzoulaki, I., Downey, P., et al. (2015) · BMC Public Health · doi:10.1186/s12889-015-2522-7 · Cited by 158
“These included: 3D carotid ultrasound to measure intima media thickness (IMT) and carotid plaques using a Philips ultrasound system and mechano‐transducer probe [27]; full body dual energy X-ray absorptiometry (iDXA; General Electric) scan to assess bone mineral density and body composition [28]; and “microscopic” fea…”
Method
Metadata
- Authors
- Murgatroyd, H.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2004-07-01
- Volume
- 88
- Issue
- 7
- Pages
- 920-924
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2049309539
- Cited by
- 150
- References
- 2
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.