The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enhanced optical coherence tomography imaging by multiple scan averaging
Open accessAbstract
AIMS: To describe a method for computerised alignment and averaging of sequences in optical coherence tomography (OCT) B-scans and to present selected clinical observations based on the resulting improvement in retinal imaging. METHODS: A methodological study and retrospective investigation of selected cases. Five human subjects were included, one healthy subject, two patients with central serous chorioretinopathy, one patient with branch retinal vein occlusion, and one patient with cilioretinal artery pseudo-occlusion. Based on computerised alignment of sets of B-scans obtained at identical retinal locations, average OCT images were produced and displayed in false colour or grayscale. These enhanced tomograms were compared with other morphological and functional characteristics. RESULTS: Improved retinal imaging enabled assignment of the OCT image to retinal anatomy particularly at the outer layer of the photoreceptors and the retinal pigment epithelium, both in the healthy eye and in pathology. Identification of both post-oedematous structural disorganisation as well as post-ischaemic attenuation of the inner retina was superior to standard OCT images. CONCLUSIONS: Averaging of multiple OCT B-scans enhances the quality of retinal imaging sufficiently to reveal new details of retinal pathophysiology. Using the technique on OCT3 scans enables visualisation of details comparable with the results obtained using ultra high resolution OCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ultrahigh-resolution ophthalmic optical coherence tomography
Drexler, W., Morgner, U., Ghanta, R. K., Kärtner, F. X., Schuman, J. S., & Fujimoto, J. G. (2001) · Nature Medicine · doi:10.1038/86589 · Cited by 962
Cited by
Choroidal Thickness in Normal Eyes Measured Using Cirrus HD Optical Coherence Tomography
Manjunath, V., Taha, M., Fujimoto, J. G., & Duker, J. S. (2010) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2010.04.018 · Cited by 490
Kraus, M. F., Potsaid, B., Mayer, M. A., Bock, R., Baumann, B., Liu, J. J., Hornegger, J., & Fujimoto, J. G. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001182 · Cited by 366
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Manjunath, V., Goren, J., Fujimoto, J. G., & Duker, J. S. (2011) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.03.008 · Cited by 277
LACK OF AUTOFLUORESCENCE IN FUNDUS ALBIPUNCTATUS ASSOCIATED WITH MUTATIONS IN RDH5
Schatz, P., Preising, M., Lorenz, B., Sander, B., Larsen, M., Eckstein, C., & Rosenberg, T. (2010) · Retina · doi:10.1097/iae.0b013e3181dc050a · Cited by 44
Self-citation
Metadata
- Authors
- Sander, B.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2005-02-01
- Volume
- 89
- Issue
- 2
- Pages
- 207-212
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2071944333
- Cited by
- 187
- References
- 1
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced optical coherence tomography imaging by multiple scan averaging. https://app.cochat.ai/papers/10.1136/bjo.2004.045989
- The paper
- Sander, B. (2005). Enhanced optical coherence tomography imaging by multiple scan averaging. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.2004.045989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.