CoChat

Cost-effectiveness of implementing automated grading within the national screening programme for diabetic retinopathy in Scotland

Open access
Scotland, G S, McNamee, P, Philip, S, Fleming, A D, Goatman, K A, Prescott, G J, Fonseca, S, Sharp, P F, Olson, J A · 2007 · British Journal of Ophthalmology
Cited by 107

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIMS: National screening programmes for diabetic retinopathy using digital photography and multi-level manual grading systems are currently being implemented in the UK. Here, we assess the cost-effectiveness of replacing first level manual grading in the National Screening Programme in Scotland with an automated system developed to assess image quality and detect the presence of any retinopathy. METHODS: A decision tree model was developed and populated using sensitivity/specificity and cost data based on a study of 6722 patients in the Grampian region. Costs to the NHS, and the number of appropriate screening outcomes and true referable cases detected in 1 year were assessed. RESULTS: For the diabetic population of Scotland (approximately 160,000), with prevalence of referable retinopathy at 4% (6400 true cases), the automated strategy would be expected to identify 5560 cases (86.9%) and the manual strategy 5610 cases (87.7%). However, the automated system led to savings in grading and quality assurance costs to the NHS of 201,600 pounds per year. The additional cost per additional referable case detected (manual vs automated) totalled 4088 pounds and the additional cost per additional appropriate screening outcome (manual vs automated) was 1990 pounds. CONCLUSIONS: Given that automated grading is less costly and of similar effectiveness, it is likely to be considered a cost-effective alternative to manual grading.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjo.2007.120972

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 107

Metadata

Authors
Scotland, G. S., McNamee, P., Philip, S., Fleming, A. D., Goatman, K. A., Prescott, G. J., Fonseca, S., Sharp, P. F., & Olson, J. A.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2007-06-21
Volume
91
Issue
11
Pages
1518-1523
ISSN
0007-1161 (ISSN-L)
OpenAlex
W2140542365
Cited by
107
References
1
FWCI
2.74
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cost-effectiveness of implementing automated grading within the national screening programme for diabetic retinopathy in Scotland. https://app.cochat.ai/papers/10.1136/bjo.2007.120972
The paper
Scotland, G. S., McNamee, P., Philip, S., Fleming, A. D., Goatman, K. A., Prescott, G. J., Fonseca, S., Sharp, P. F., & Olson, J. A. (2007). Cost-effectiveness of implementing automated grading within the national screening programme for diabetic retinopathy in Scotland. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.2007.120972

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.