Cost-effectiveness of implementing automated grading within the national screening programme for diabetic retinopathy in Scotland
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: National screening programmes for diabetic retinopathy using digital photography and multi-level manual grading systems are currently being implemented in the UK. Here, we assess the cost-effectiveness of replacing first level manual grading in the National Screening Programme in Scotland with an automated system developed to assess image quality and detect the presence of any retinopathy. METHODS: A decision tree model was developed and populated using sensitivity/specificity and cost data based on a study of 6722 patients in the Grampian region. Costs to the NHS, and the number of appropriate screening outcomes and true referable cases detected in 1 year were assessed. RESULTS: For the diabetic population of Scotland (approximately 160,000), with prevalence of referable retinopathy at 4% (6400 true cases), the automated strategy would be expected to identify 5560 cases (86.9%) and the manual strategy 5610 cases (87.7%). However, the automated system led to savings in grading and quality assurance costs to the NHS of 201,600 pounds per year. The additional cost per additional referable case detected (manual vs automated) totalled 4088 pounds and the additional cost per additional appropriate screening outcome (manual vs automated) was 1990 pounds. CONCLUSIONS: Given that automated grading is less costly and of similar effectiveness, it is likely to be considered a cost-effective alternative to manual grading.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cost-Effectiveness of Detecting and Treating Diabetic Retinopathy
Javitt, J. C., & Aiello, L. P. (1996) · Annals of Internal Medicine · doi:10.7326/0003-4819-124-1_part_2-199601011-00017 · Cited by 411
Cited by
Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy
Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., et al. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.1743 · Cited by 463
Xie, Y., Nguyen, Q. D., Hamzah, H., Lim, G., Bellemo, V., Gunasekeran, D. V., Yip, M. Y. T., Qi Lee, X., Hsu, W., Li Lee, M., et al. (2020) · The Lancet Digital Health · doi:10.1016/s2589-7500(20)30060-1 · Cited by 288
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Automated Diabetic Retinopathy Image Assessment Software
Tufail, A., Rudisill, C., Egan, C., Kapetanakis, V. V., Salas-Vega, S., Owen, C. G., Lee, A., Louw, V., Anderson, J., Liew, G., et al. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.11.014 · Cited by 283
Retinal Imaging Techniques for Diabetic Retinopathy Screening
Goh, J. K. H., Cheung, C. Y., Sim, S. S., Tan, P. C., Tan, G. S. W., & Wong, T. Y. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816629491 · Cited by 174
Metadata
- Authors
- Scotland, G. S., McNamee, P., Philip, S., Fleming, A. D., Goatman, K. A., Prescott, G. J., Fonseca, S., Sharp, P. F., & Olson, J. A.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2007-06-21
- Volume
- 91
- Issue
- 11
- Pages
- 1518-1523
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2140542365
- Cited by
- 107
- References
- 1
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cost-effectiveness of implementing automated grading within the national screening programme for diabetic retinopathy in Scotland. https://app.cochat.ai/papers/10.1136/bjo.2007.120972
- The paper
- Scotland, G. S., McNamee, P., Philip, S., Fleming, A. D., Goatman, K. A., Prescott, G. J., Fonseca, S., Sharp, P. F., & Olson, J. A. (2007). Cost-effectiveness of implementing automated grading within the national screening programme for diabetic retinopathy in Scotland. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.2007.120972
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.