The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy
Abstract
IMPORTANCE: The diagnostic accuracy of computer detection programs has been reported to be comparable to that of specialists and expert readers, but no computer detection programs have been validated in an independent cohort using an internationally recognized diabetic retinopathy (DR) standard. OBJECTIVE: To determine the sensitivity and specificity of the Iowa Detection Program (IDP) to detect referable diabetic retinopathy (RDR). DESIGN AND SETTING: In primary care DR clinics in France, from January 1, 2005, through December 31, 2010, patients were photographed consecutively, and retinal color images were graded for retinopathy severity according to the International Clinical Diabetic Retinopathy scale and macular edema by 3 masked independent retinal specialists and regraded with adjudication until consensus. The IDP analyzed the same images at a predetermined and fixed set point. We defined RDR as more than mild nonproliferative retinopathy and/or macular edema. PARTICIPANTS: A total of 874 people with diabetes at risk for DR. MAIN OUTCOME MEASURES: Sensitivity and specificity of the IDP to detect RDR, area under the receiver operating characteristic curve, sensitivity and specificity of the retinal specialists' readings, and mean interobserver difference (κ). RESULTS: The RDR prevalence was 21.7% (95% CI, 19.0%-24.5%). The IDP sensitivity was 96.8% (95% CI, 94.4%-99.3%) and specificity was 59.4% (95% CI, 55.7%-63.0%), corresponding to 6 of 874 false-negative results (none met treatment criteria). The area under the receiver operating characteristic curve was 0.937 (95% CI, 0.916-0.959). Before adjudication and consensus, the sensitivity/specificity of the retinal specialists were 0.80/0.98, 0.71/1.00, and 0.91/0.95, and the mean intergrader κ was 0.822. CONCLUSIONS: The IDP has high sensitivity and specificity to detect RDR. Computer analysis of retinal photographs for DR and automated detection of RDR can be implemented safely into the DR screening pipeline, potentially improving access to screening and health care productivity and reducing visual loss through early treatment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1990) · Choice Reviews Online · doi:10.5860/choice.27-3338 · Cited by 35,305
(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Ranibizumab for Diabetic Macular Edema
Nguyen, Q. D., Brown, D. M., Marcus, D. M., Boyer, D. S., Patel, S., Feiner, L., Gibson, A., Sy, J., Rundle, A. C., Hopkins, J. J., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.039 · Cited by 1,621
Elman, M. J., Aiello, L. P., Beck, R. W., Bressler, N. M., Bressler, S. B., Edwards, A. R., Ferris, F. L., Friedman, S. M., Glassman, A. R., Miller, K. M., et al. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.02.031 · Cited by 1,428
Mitchell, P., Bandello, F., Schmidt-Erfurth, U., Lang, G. E., Massin, P., Schlingemann, R. O., Sutter, F., Simader, C., Burian, G., Gerstner, O., et al. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2011.01.031 · Cited by 1,326
Self-citationStatistics Notes: Diagnostic tests 3: receiver operating characteristic plots
Altman, D. G., & Bland, J. M. (1994) · BMJ · doi:10.1136/bmj.309.6948.188 · Cited by 599
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Self-citationAutomatic detection of red lesions in digital color fundus photographs
Niemeijer, M., van Ginneken, B., Staal, J., Suttorp-Schulten, M. S. A., & Abramoff, M. D. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.843738 · Cited by 504
Self-citationDavis, M. D., Fisher, M. R., Gangnon, R. E., Barton, F. B., Aiello, L. M., Chew, E. Y., Ferris, F. L., & Knatterud, G. L. (1998) · PubMed · Cited by 455
Cited by
Gulshan, V., Peng, L., Coram, M., Stumpe, M. C., Wu, D., Narayanaswamy, A., Venugopalan, S., Widner, K., Madams, T., Cuadros, J., et al. (2016) · JAMA · doi:10.1001/jama.2016.17216 · Cited by 7,697
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Self-citationArtificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Abràmoff, M. D., Lou, Y., Erginay, A., Clarida, W., Amelon, R., Folk, J. C., & Niemeijer, M. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19964 · Cited by 1,101
Self-citation
Metadata
- Authors
- Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., Lamard, M., Moga, D. C., Quellec, G., & Niemeijer, M.
- Venue
- JAMA Ophthalmology
- Publisher
- American Medical Association (AMA)
- Published
- 2013-03-01
- Volume
- 131
- Issue
- 3
- Pages
- 351
- ISSN
- 2168-6165 (ISSN-L)
- OpenAlex
- W2073244572
- Cited by
- 463
- References
- 31
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy. https://app.cochat.ai/papers/10.1001/jamaophthalmol.2013.1743
- The paper
- Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., Lamard, M., Moga, D. C., Quellec, G., & Niemeijer, M. (2013). Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy. JAMA Ophthalmology. https://doi.org/10.1001/jamaophthalmol.2013.1743
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.