Cited by 263Glaucoma and retinal disordersBlood Pressure and Hypertension StudiesCorneal surgery and disorders

Diurnal intraocular pressure variations: an analysis of 690 diurnal curves.

Open access
David, R, Zangwill, L, Briscoe, D, Dagan, M, Yagev, R, Yassur, Y·1992·British Journal of Ophthalmology

Abstract

Out of a total of 2272 diurnal curves (DC) of intraocular pressure (IOP) obtained from 1178 patients 690 first curves of the right eye of all patients were analysed. For each DC there were 4-6 IOP readings taken between 8 am and 6.30 pm of the same day. The patients' diagnosis, age, sex, type of IOP lowering medication, diabetes, and the calendar month of the year were recorded. In 40% of cases the highest IOP was found at the earliest morning measurement with some 65% of peaks occurring before noon. The lowest IOP measurement showed no specific predilection for any particular time of the day. These findings were true for all diagnosis groups. The mean range of IOP fluctuation during the DC was 5.0 mm Hg in normals, 5.8 mm Hg in patients with open angle glaucoma (OAG), and 6.8 mm Hg in patients with ocular hypertension (OHT). Patients treated with timolol had a lower mean IOP fluctuation range than those on other types of IOP lowering treatment. No association was found between all other parameters examined and the diurnal IOP distribution.

Integrity signals

Registry

Crossref · 10.1136/bjo.76.5.280

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The normal range for intraocular pressure is reportedly 7-21 mmHg, and daily fluctuations in intraocular pressure can show an approximate range of 3-7 mmHg.

    “The normal range for IOPs is reportedly 7–21 mmHg, and daily fluctuations in IOP can show an approximate range of 3–7 mmHg [22–25].”

Cited by

Sorted by citations

Authors
David, R., Zangwill, L., Briscoe, D., Dagan, M., Yagev, R., & Yassur, Y.
Affiliations
Soroka Medical Center (IL)
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
1992-05-01
Volume
76
Issue
5
Pages
280-283
ISSN
0007-1161 (ISSN-L)
OpenAlex
W2168563911
Cited by
263
References
0
Citations by year
2026: 12 · 2025: 4 · 2024: 9 · 2023: 9 · 2022: 9 · 2021: 16 · 2020: 12 · 2019: 9 · 2018: 12 · 2017: 12 · 2016: 13 · 2015: 11 · 2014: 11 · 2013: 6 · 2012: 5
FWCI
1.74
Type
journal article
Language
en
Open access
Locations
  • British Journal of Ophthalmology (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • HighWire Press Open Archive (submittedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Blood Pressure and Hypertension Studies
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
Keywords
intraocular pressure, diurnal variation, circadian rhythm, open-angle glaucoma, ocular hypertension, timolol, IOP-lowering medications
MeSH terms
Adrenergic beta-Antagonists, Aged, Circadian Rhythm, Female, Glaucoma, Open-Angle, Humans, Intraocular Pressure, Male, Middle Aged, Ocular Hypertension, Seasons

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review