CoChat

Prophylactic laser treatment in early age related maculopathy reduced the incidence of exudative complications

Open access
Frennesson, C, Nilsson, S E G · 1998 · British Journal of Ophthalmology
Cited by 58

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIM: To investigate the effect of prophylactic laser treatment on drusen area and incidence of exudative lesions in patients with soft drusen maculopathy. METHODS: In a prospective study, patients with early age related maculopathy (ARM) and good visual acuity were randomized to laser treatment or to a control group. Each group consisted of two subgroups: a fellow eye group and a bilateral drusen group. At 3 years, 36 of 38 enrolled patients remained in the study. Photocoagulation was performed with an argon green laser, approximately 100 mild laser burns being placed on and between the drusen in a perifoveal temporal horseshoe-shaped area. Both cases and controls were subjected to fundus colour photographs and fluorescein angiograms at regular intervals, and the drusen area was calculated in both photographs and angiograms. At baseline, there were no significant differences (p > 0.3-0.8) in drusen area between the groups. RESULTS: In the treatment group, mean drusen area decreased significantly in the fundus photographs as well as in the angiograms (p < 0.001). Visual acuity and colour contrast sensitivity (CCS) did not change significantly. All these results are valid also for the subgroups. In the control group, however, mean drusen area increased significantly (p < 0.001). Mean visual acuity decreased significantly (p < 0.01) as did the colour contrast sensitivity along the tritan axis (p = 0.02). For the fellow eye control group (n = 7), the increase in drusen area in fundus photographs and the decrease in CCS along the tritan axis were not statistically significant (p = 0.57 and p = 0.37, respectively). Furthermore, at 3 years, five patients in the control group showed exudative lesions (1/7 in the fellow eye group and 4/12 in the bilateral drusen group), whereas no such complications occurred in the treatment group. One patient developed a small atrophy, however. Thus, there is now a significant difference (p = 0.047), however with a large 95% confidence interval, 0.06-0.46, regarding exudative complications between the treated group and the control group in our small patient material. CONCLUSION: Perifoveal mild laser treatment causes a reduction in drusen area in patients with soft drusen maculopathy and may lower the incidence of exudative lesions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjo.82.10.1169

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 58

Metadata

Authors
Frennesson, C., & Nilsson, S. E. G.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
1998-10-01
Volume
82
Issue
10
Pages
1169-1174
ISSN
0007-1161 (ISSN-L)
OpenAlex
W1965020438
Cited by
58
References
1
FWCI
3.08
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.