The DOI matches its Crossref record.
Selective laser trabeculoplasty v argon laser trabeculoplasty: a prospective randomised clinical trial
Open accessAbstract
AIMS: To compare the effectiveness of selective laser trabeculoplasty (SLT, a 532 nm Nd:YAG laser) with argon laser trabeculoplasty (ALT) in lowering the intraocular pressure (IOP) in patients with medically uncontrolled open angle glaucoma. METHODS: A prospective randomised clinical trial was designed. Patients were randomised to treatment with either SLT or ALT and were evaluated at 1 hour, 1 week, 1, 3, and 6 months post-laser. RESULTS: There were 18 eyes in each group. Baseline characteristics were similar in both groups. In the SLT group the mean IOP at baseline, 1, 3, and 6 months was 22.8 (SD 3.0), 20.1 (4.6), 19.3 (6.0), and 17.8 (4.8) mm Hg, respectively. In the ALT group, the mean IOP at baseline, 1, 3, and 6 months was 22.5 (3.6), 19.5 (4.7), 19.6 (5.6), and 17.7 (3.3) mm Hg, respectively. There was a greater anterior chamber reaction, 1 hour after SLT v ALT (p< 0.01). Patients with previous failed ALT had a better reduction in IOP with SLT than with repeat ALT (6.8 (2. 4) v 3.6 (1.8) mm Hg; p = 0.01). CONCLUSION: SLT appears to be equivalent to ALT in lowering IOP during the first 6 months after treatment. There is a slightly greater anterior chamber reaction 1 hour after SLT. Patients with previous failed ALT had a significantly greater drop in IOP when treated with SLT v ALT. These results need to be confirmed with a larger sample size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Weinreb, R. N., & Khaw, P. T. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16257-0 · Cited by 2,222
Primary Open-Angle Glaucoma Preferred Practice Pattern®
Gedde, S. J., Vinod, K., Wright, M. M., Muir, K. W., Lind, J. T., Chen, P. P., Li, T., & Mansberger, S. L. (2021) · Ophthalmology · doi:10.1016/j.ophtha.2020.10.022 · Cited by 474
Current management of glaucoma
Lusthaus, J., & Goldberg, I. (2019) · Medical Journal of Australia · doi:10.5694/mja2.50020 · Cited by 354
Glaucoma treatment trends: a review
Conlon, R., Saheb, H., & Ahmed, I. I. K. (2017) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2016.07.013 · Cited by 344
Kramer, T. R., & Noecker, R. J. (2001) · Ophthalmology · doi:10.1016/s0161-6420(00)00660-6 · Cited by 282
Metadata
- Authors
- Damji, K. F., Shah, K. C., Rock, W. J., Bains, H. S., & Hodge, W. G.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 1999-06-01
- Volume
- 83
- Issue
- 6
- Pages
- 718-722
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2083500802
- Cited by
- 227
- References
- 0
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.