Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 185

The DOI matches its Crossref record.

Evaluation of the Zeiss retinal vessel analyser

Open access
Polak, K. · 2000 · British Journal of Ophthalmology

Abstract

AIM: To investigate the reproducibility and sensitivity of the Zeiss retinal vessel analyser, a new method for the online determination of retinal vessel diameters in healthy subjects. METHODS: Two model drugs were administered, a peripheral vasoconstrictor (the alpha receptor agonist phenylephrine) and a peripheral vasodilator (the nitric oxide donor sodium nitroprusside) in stepwise increasing doses. Nine healthy young subjects were studied in a placebo controlled double masked three way crossover design. Subjects received intravenous infusions of either placebo or stepwise increasing doses of phenylephrine (0.5, 1, or 2 microg/kg/min) or sodium nitroprusside (0.5, 1, or 2 microg/kg/min). Retinal vessel diameters were measured with the new Zeiss retinal vessel analyser. Retinal leucocyte velocity, flow, and density were measured with the blue field entoptic technique. The reproducibility of measurements was assessed with coefficients of variation and intraclass correlation coefficients. RESULTS: Placebo and phenylephrine did not influence retinal haemodynamics, although the alpha receptor antagonist significantly increased blood pressure. Sodium nitroprusside induced a significant increase in retinal venous and arterial diameters (p<0.001 each), leucocyte density (p=0.001), and leucocyte flow (p=0.024) despite lowering blood pressure to a significant degree. For venous and arterial vessel size measurements short term coefficients of variation were 1.3% and 2.6% and intraclass correlation coefficients were 0.98 and 0.96, respectively. The sensitivity was between 3% and 5% for retinal veins and 5% and 7% for retinal arteries. CONCLUSIONS: These data indicate that the Zeiss retinal vessel analyser is an accurate system for the assessment of retinal diameters in healthy subjects. In addition, nitric oxide appears to have a strong influence on retinal vascular tone.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjo.84.11.1285

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 185

Metadata

Authors
Polak, K.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2000-11-01
Volume
84
Issue
11
Pages
1285-1290
ISSN
0007-1161 (ISSN-L)
OpenAlex
W2100864127
Cited by
185
References
0
FWCI
6.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Zeiss retinal vessel analyser. https://app.cochat.ai/papers/10.1136/bjo.84.11.1285
The paper
Polak, K. (2000). Evaluation of the Zeiss retinal vessel analyser. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.84.11.1285

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.