The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research
Open accessAbstract
AIM: To investigate the repeatability and sensitivity of two commonly used sine wave patch charts for contrast sensitivity (CS) measurement in cataract and refractive surgery outcomes. METHODS: The Vistech CS chart and its descendant, the Functional Acuity Contrast Test (FACT), were administered in three experiments: (1) Post-LASIK and age matched normal subjects; (2) Preoperative cataract surgery and age matched normal subjects; (3) Test-retest repeatability data in normal subjects. RESULTS: Contrast sensitivity was similar between post-LASIK and control groups and between the Vistech and FACT charts. The percentage of subjects one month post-LASIK achieving the maximum score across spatial frequencies (1.5, 3, 6, 12, 18 cycles per degree) were (50, 33, 13, 13, 0 respectively) for FACT, but only (0, 0, 13, 4, 0 respectively) for Vistech. A small number of cataract patients also registered the maximum score on the FACT, but up to 60% did not achieve the minimum score. Test-retest intraclass correlation coefficients varied from 0.28 to 0.64 for Vistech and 0.18 to 0.45 for FACT. Bland-Altman limits of agreement across spatial frequencies were between +/-0.30 and +/-0.85 logCS for Vistech, and +/-0.30 to +/-0.75 logCS for FACT. DISCUSSION: The Vistech was confirmed as providing poorly repeatable data. The FACT chart, likely because of a smaller step size, showed slightly better retest agreement. However, the reduced range of scores on the chart due to the smaller step size led to ceiling (post-LASIK) and floor (cataract) effects. These problems could mask subtle differences between groups of patients with near normal visual function as found post-refractive or cataract surgery. The Vistech and FACT CS charts are ill suited for refractive or cataract surgery outcomes research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Cited by
McAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436
Self-citationBayesian adaptive estimation of the contrast sensitivity function: The quick CSF method
Lesmes, L. A. (2010) · Journal of Vision · doi:10.1167/10.3.17 · Cited by 333
Presbyopia: Effectiveness of correction strategies
Wolffsohn, J. S., & Davies, L. N. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.09.004 · Cited by 324
Visual performance of two simultaneous vision multifocal contact lenses
Madrid‐Costa, D., García‐Lázaro, S., Albarrán‐Diego, C., Ferrer‐Blasco, T., & Montés‐Micó, R. (2013) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12008 · Cited by 46
Metadata
- Authors
- Pesudovs, K.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2004-01-01
- Volume
- 88
- Issue
- 1
- Pages
- 11-16
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2107878854
- Cited by
- 176
- References
- 2
- FWCI
- 3.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research. https://app.cochat.ai/papers/10.1136/bjo.88.1.11
- The paper
- Pesudovs, K. (2004). The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.88.1.11
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.