CoChat

Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study

Open access
Ehlers, Justis P, Kaiser, Peter K, Srivastava, Sunil K · 2014 · British Journal of Ophthalmology
Cited by 131

The DOI matches its Crossref record.

Abstract

Significant integrative advances are needed for intraoperative optical coherence tomography (iOCT) to achieve widespread use across ophthalmic surgery. A surgeon feedback system that provides microscope integration, heads-up display and foot pedal control of the OCT scan location represents a major interval advance in ophthalmic surgery. In this report, we describe the preliminary findings of the Determination of feasibility of Intraoperative Spectral domain microscope Combined/integrated OCT Visualisation during En face Retinal and ophthalmic surgery (DISCOVER) study, a multisurgeon investigational device study examining the role of microscope integrated iOCT systems with surgeon heads-up display feedback (eg, Carl Zeiss Meditec RESCAN 700, Cole Eye Institute iOCT prototype). During surgical manoeuvres in anterior segment and posterior segment surgery, this technology provides rapid visualisation of the area of interest and provides the surgeon with information regarding instrument-tissue interactions. This system represents a major advance in iterative technology for iOCT and may provide the first widely available platform for surgeons to seamlessly assimilate this technology into the operating room theatre.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjophthalmol-2014-305294

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 131

Metadata

Authors
Ehlers, J. P., Kaiser, P. K., & Srivastava, S. K.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2014-04-29
Volume
98
Issue
10
Pages
1329-1332
ISSN
  • 0007-1161 (ISSN-L)
  • 1468-2079
OpenAlex
W2131873618
Cited by
131
References
0
FWCI
10.93
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study. https://app.cochat.ai/papers/10.1136/bjophthalmol-2014-305294
The paper
Ehlers, J. P., Kaiser, P. K., & Srivastava, S. K. (2014). Intraoperative optical coherence tomography using the RESCAN 700: preliminary results from the DISCOVER study. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2014-305294

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.