CoChat

Review and meta-analysis of ab-interno trabeculectomy outcomes

Kaplowitz, Kevin, Bussel, Igor I, Honkanen, Robert, Schuman, Joel S, Loewen, Nils A · 2016 · British Journal of Ophthalmology
Cited by 199

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

We analysed all of the PubMed publications on ab-interno trabeculectomy (AIT) with the Trabectome (Neomedix, Irvine, California, USA) to determine the reduction in intraocular pressure (IOP) and medications following the procedure. For IOP outcomes, PubMed was searched for 'trabectome', 'ab interno trabeculotomy' and 'ab interno trabeculectomy' and all available papers retrieved. The meta-analysis used a random-effects model to achieve conservative estimates and assess statistical heterogeneity. To investigate complications, we included all abstracts from the American Glaucoma Society, American Academy of Ophthalmology, American Society of Cataract and Refractive Surgery and the Association for Research in Vision and Ophthalmology. The overall arithmetic mean baseline IOP for standalone Trabectome was 26.71±1.34 mm Hg and decreased by 10.5±1.9 mm Hg (39% decrease) on 0.99±0.54 fewer medications. Defining success as IOP ≤21 with a 20% decrease while avoiding reoperation, the overall average success rate after 2 years was 46±34%. For combined phacoemulsification-Trabectome, the baseline IOP of 21±1.31 mm Hg decreased by 6.24±1.98 mm Hg (27% decrease) on 0.76±0.35 fewer medications. The success rate using the same definition at 2 years was 85±7%. The weighted mean IOP difference from baseline to study endpoint was 9.77 mm Hg (95% CI 8.90 to 10.64) standalone and 6.04 mm Hg (95% CI 4.95 to 7.13) for combined cases. Despite heterogeneity, meta-analysis showed significant and consistent decrease in IOP and medications from baseline to end point in AIT and phaco-AIT. The rate of visually threatening complications was <1%. On average, trabectome lowers the IOP by approximately 31% to a final IOP near 15 mm Hg while decreasing the number of medications by less than one, with a low rate of serious complications. After 2 years, the overall average success rate is 66%.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjophthalmol-2015-307131

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 199

Metadata

Authors
Kaplowitz, K., Bussel, I. I., Honkanen, R., Schuman, J. S., & Loewen, N. A.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2016-01-05
Volume
100
Issue
5
Pages
594-600
ISSN
  • 0007-1161 (ISSN-L)
  • 1468-2079
OpenAlex
W2227600151
Cited by
199
References
10
FWCI
10.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Review and meta-analysis of ab-interno trabeculectomy outcomes. https://app.cochat.ai/papers/10.1136/bjophthalmol-2015-307131
The paper
Kaplowitz, K., Bussel, I. I., Honkanen, R., Schuman, J. S., & Loewen, N. A. (2016). Review and meta-analysis of ab-interno trabeculectomy outcomes. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2015-307131

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.