Release of experimental retinal vein occlusions by direct intraluminal injection of ocriplasmin
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE: Retinal vein occlusions (RVO) are a major cause of vision loss in people aged 50 years and older. Current therapeutic options limit the consequences of RVO but do not eliminate the cause. Cannulation of the involved vessel and removal of the clot may provide a more permanent solution with a less demanding follow-up. However, cannulation of smaller retinal veins remains challenging. This paper explores the use of ocriplasmin (recombinant plasmin without its kringles) to clear RVO, using a robotic micromanipulator. METHODS: Branch RVO were induced in a porcine model with rose bengal followed by 532 nm endolaser to the superior venous branch of the optic nerve. The vein was cannulated proximal to the occlusion or beyond the first branching vessel from the obstruction. The vein was infused with a physiologic citric acid buffer solution (CAM) or CAM/ocriplasmin. The time of cannulation, number of attempts, and the ability to release the thrombus were recorded. RESULTS: Cannulation and infusion was possible in all the cases. The use of a micromanipulator allowed for a consistent cannulation of the retinal vein and positional stability allowed the vein to remain cannulated for up to 20 min. In none of the attempts (5/5) with CAM did the thrombus dissolve, despite repeat infusion/relaxation cycles. In 7/7 injections of CAM/ocriplasmin near to the point of obstruction, the clot started to dissolve within a few minutes of injection. An infusion, attempted beyond the first venous branch point proximal to the clot, was unsuccessful in 2/3 attempts. CONCLUSIONS: Ocriplasmin is effective in resolving RVO if injected close to the site of occlusion with the use of a micromanipulator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
First-in-human study of the safety and viability of intraocular robotic surgery
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0248-4 · Cited by 231
Self-citationFirst-in-Human robot-assisted subretinal drug delivery under local anesthesia
Cehajic-Kapetanovic, J., Xue, K., Edwards, T. L., Meenink, T. C., Beelen, M. J., Naus, G. J., de Smet, M. D., & MacLaren, R. E. (2022) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2021.11.011 · Cited by 78
Self-citationAnimal models of retinal vein occlusion
Khayat, M., Lois, N., Williams, M., & Stitt, A. W. (2017) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.17-22788 · Cited by 42
“Endophotocoagulation has also been used to achieve a vein occlusion; for this technique, an endolaser probe is inserted into the eye through a sclerostomy (without removing the vitreous) and retinal veins are then photocoagulated until evidence of occlusion is seen.(146,147)”
MethodPig models in retinal research and retinal disease
McCall, M. A. (2024) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a041296 · Cited by 21
Metadata
- Authors
- de Smet, M. D., Stassen, J. M., Meenink, T. C. M., Janssens, T., Vanheukelom, V., Naus, G. J. L., Beelen, M. J., & Jonckx, B.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2016-09-28
- Volume
- 100
- Issue
- 12
- Pages
- 1742-1746
- ISSN
- 0007-1161 (ISSN-L)
- 1468-2079
- OpenAlex
- W2468528281
- Cited by
- 46
- References
- 0
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Release of experimental retinal vein occlusions by direct intraluminal injection of ocriplasmin. https://app.cochat.ai/papers/10.1136/bjophthalmol-2016-309190
- The paper
- de Smet, M. D., Stassen, J. M., Meenink, T. C. M., Janssens, T., Vanheukelom, V., Naus, G. J. L., Beelen, M. J., & Jonckx, B. (2016). Release of experimental retinal vein occlusions by direct intraluminal injection of ocriplasmin. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2016-309190
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.