Enhancing the efficacy of the 20 m multistage shuttle run test
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective:Maximal oxygen uptake (Vo 2max) of 44 ml kg−1 min−1 is an accepted criterion (Vo 2CR) below which health and fitness for young male adults may be compromised. New algorithms validated for Vo 2CR screening using the 20 m multistage shuttle run test (20mMST) were developed. Methods:Vo 2max was assessed in 110 males using a stationary gas analyser in a treadmill test (TT) and in 40 of these subjects using a portable gas analyser in the 20mMST. Vo 2max predicted from the 20mMST in 70 subjects was used for cross validation. Two equations predicting Vo 2max during 20mMST (EQ MST) and TT (EQ TT) were developed. Results:Significant energy cost variance (EC V) was detected between TT and 20mMST (p<0.001), correlated significantly with subject height, and was a significant predictor of Vo 2max differences between TT and 20mMST. The r2 of EQ MST was 0.92 (p<0.001). Predicted Vo 2max values from EQ MST correlated with directly measured 20mMST Vo 2max at r = 0.96 (p<0.001). ANOVA detected no mean difference (p>0.05) between predicted and measured values. Prevalence of low fitness based on Vo 2CR was 0.37. McNemar χ 2 indicated significant differences in sensitivity (p<0.001) and specificity (p<0.05) between the original 20mMST equation (EQ LÉG) and EQ TT, regarding Vo 2CR screening. Cohen’s κ demonstrated higher agreement with TT Vo 2max for EQ TT(p<0.001) than EQ LÉG(p<0.05). TT Vo 2max correlated with the end result of both EQ LÉG and EQ TT at r = 0.75 (p<0.001). Unlike EQ TT(p>0.05), mean predicted Vo 2max from EQ LÉG was significantly higher compared to TT Vo 2max(p<0.001). Conclusion:These algorithms increase the efficacy of 20mMST to accurately evaluate aspects of health and fitness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
De Backer, G. (2003) · European Heart Journal · doi:10.1016/s0195-668x(03)00347-6 · Cited by 2,251
The Relative Value of Fat and Carbohydrate as Sources of Muscular Energy
Krogh, A., & Lindhard, J. (1920) · Biochemical Journal · doi:10.1042/bj0140290 · Cited by 411
Cited by
Tomkinson, G. R., Lang, J. J., Tremblay, M. S., Dale, M., LeBlanc, A. G., Belanger, K., Ortega, F. B., & Léger, L. (2017) · British Journal of Sports Medicine · doi:10.1136/bjsports-2016-095987 · Cited by 308
Manimmanakorn, A., Hamlin, M. J., Ross, J. J., Taylor, R., & Manimmanakorn, N. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.08.009 · Cited by 195
Chan, A. P. C., Yi, W., Wong, D. P., Yam, M. C. H., & Chan, D. W. M. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.07.006 · Cited by 91
“Wearing the portable gas analyzer during the work does not significantly alter the participants’ energy demands [41].”
BackgroundDamage-Associated Molecular Patterns and Th-Cell-Related Cytokines Released after Progressive Effort
Kostrzewa-Nowak, D., Ciechanowicz, A., Clark, J. S. C., & Nowak, R. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9030876 · Cited by 19
Hannaian, S. J., Orlando, M. N., Abou Sawan, S., Mazzulla, M., West, D. W. D., & Moore, D. R. (2020) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2020.568740 · Cited by 4
Metadata
- Authors
- Flouris, A. D., Metsios, G. S., & Koutedakis, Y.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2005-02-23
- Volume
- 39
- Issue
- 3
- Pages
- 166-170
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2116966534
- Cited by
- 85
- References
- 3
- FWCI
- 7.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.