Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 199

The DOI matches its Crossref record.

Ultrasonographic tissue characterisation of human Achilles tendons: quantification of tendon structure through a novel non-invasive approach

Open access
van Schie, H T M, de Vos, R J, de Jonge, S, Bakker, E M, Heijboer, M P, Verhaar, J A N, Tol, J L, Weinans, H · 2010 · British Journal of Sports Medicine

Abstract

Objective: To assess whether three-dimensional imaging of the Achilles tendon by ultrasonographic tissue characterisation (UTC) can differentiate between symptomatic and asymptomatic tendons. Design: Case-control study. Setting: Sports Medical Department of the Hague Medical Centre. Patients: Twenty-six tendons from patients with chronic midportion Achilles tendinopathy were included. The “matched” control group consisted of 26 asymptomatic tendons. Interventions: Symptomatic and asymptomatic tendons were scanned using the UTC procedure. One researcher performed the ultrasonographic data collection. These blinded data were randomised, and outcome measures were determined by two independent observers. Main outcome measurements: The raw ultrasonographic images were analysed with a customdesigned algorithm that quantifies the three-dimensional stability of echo patterns, qua intensity and distribution over contiguous transverse images. This threedimensional stability was related to tendon structure in previous studies. UTC categorises four different echotypes that represent (I) highly stable; (II) medium stable; (III) highly variable and (IV) constantly low intensity and variable distribution. The percentages of echo-types were calculated, and the maximum tendon thickness was measured. Finally, the inter-observer reliability of UTC was determined. Results: Symptomatic tendons showed less pixels in echo-types I and II than asymptomatic tendons (51.5% vs 76.6%, p<0.001), thus less three-dimensional stability of the echo pattern. The mean maximum tendon thickness was 9.2 mm in the symptomatic group and 6.8 mm in the asymptomatic group (p<0.001). The Intraclass Correlation Coefficient (ICC) for the interobserver reliability of determining the echo-types I+II was 0.95. The ICC for tendon thickness was 0.84. Conclusion: UTC can quantitatively evaluate tendon structure and thereby discriminate symptomatic and asymptomatic tendons. As such, UTC might be useful to monitor treatment protocols.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjsm.2009.061010

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 199

Metadata

Authors
van Schie, H. T. M., de Vos, R. J., de Jonge, S., Bakker, E. M., Heijboer, M. P., Verhaar, J. A. N., Tol, J. L., & Weinans, H.
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
2009-08-06
Volume
44
Issue
16
Pages
1153-1159
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W2162835160
Cited by
199
References
0
FWCI
4.80
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasonographic tissue characterisation of human Achilles tendons: quantification of tendon structure through a novel non-invasive approach. https://app.cochat.ai/papers/10.1136/bjsm.2009.061010
The paper
van Schie, H. T. M., de Vos, R. J., de Jonge, S., Bakker, E. M., Heijboer, M. P., Verhaar, J. A. N., Tol, J. L., & Weinans, H. (2010). Ultrasonographic tissue characterisation of human Achilles tendons: quantification of tendon structure through a novel non-invasive approach. British Journal of Sports Medicine. https://doi.org/10.1136/bjsm.2009.061010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.