A comparison of lactate concentration in plasma collected from the toe, ear, and fingertip after a simulated rowing exercise
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective—To examine the validity of using blood taken from the toe for the assessment of plasma lactate concentration in rowers. To achieve this, values were compared with those taken from the fingertip and earlobe. Methods—Nine subjects exercised at two separate submaximum workloads on the Concept II rowing ergometer. The loads, each lasting four minutes, elicited mean (SD) heart rate responses of 160.1 (8.5) and 180.1 (5.7) beats/min, which corresponded to 76.4 (6.1)% and 91.9 (4.7)% of the estimated heart rate maximum of the subjects. Blood was simultaneously removed after the cessation of exercise by three experimenters and was analysed for plasma lactate concentration. Results—At 76.4% of estimated heart rate maximum, the mean (SD) plasma lactate concentrations sampled from the fingertip, toe, and earlobe were 6.36 (1.58), 5.81 (1.11), and 5.29 (1.24) mmol/l respectively. At 91.9% of estimated heart rate maximum, respective values were 8.81 (2.30), 8.53 (1.37), and 8.41 (2.35) mmol/l. No significant differences (p>0.05) were found between any of the sites at either work intensity. Conclusions—The toe may offer a practical alternative for assessing the concentration of lactate during rowing, having the advantage that repeated blood samples can be removed without interruption of the rowing action.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Justification of the 4-mmol/l lactate threshold
Heck, H., Mader, A., Hess, G., Mücke, S., Müller, R., & Hollmann, W. (1985) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025824 · Cited by 888
Individual Anaerobic Threshold and Maximum Lactate Steady State
Urhausen, A., Coen, B., Weiler, B., & Kindermann, W. (1993) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021157 · Cited by 171
Cited by
Lactate Threshold Concepts: How Valid are They?
Faude, O., Kindermann, W., & Meyer, T. (2009) · Sports Medicine · doi:10.2165/00007256-200939060-00003 · Cited by 882
Ranchal-Sanchez, A., Diaz-Bernier, V. M., De La Florida-Villagran, C. A., Llorente-Cantarero, F. J., Campos-Perez, J., & Jurado-Castro, J. M. (2020) · Nutrients · doi:10.3390/nu12071912 · Cited by 63
“Samples were obtained from the ear lobe, a conventional sampling site [34], after the lobe was cleansed and sterilized with 70% ethanol.”
MethodDennis, A., Thomas, A. G., Rawlings, N. B., Near, J., Nichols, T. E., Clare, S., Johansen-Berg, H., & Stagg, C. J. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00351 · Cited by 43
Metadata
- Authors
- Forsyth, J. J., & Farrally, M. R.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2000-02
- Volume
- 34
- Issue
- 1
- Pages
- 35-38
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2096307619
- Cited by
- 54
- References
- 2
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison of lactate concentration in plasma collected from the toe, ear, and fingertip after a simulated rowing exercise. https://app.cochat.ai/papers/10.1136/bjsm.34.1.35
- The paper
- Forsyth, J. J., & Farrally, M. R. (2000). A comparison of lactate concentration in plasma collected from the toe, ear, and fingertip after a simulated rowing exercise. British Journal of Sports Medicine. https://doi.org/10.1136/bjsm.34.1.35
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.