CoChat

How well do activity monitors estimate energy expenditure? A systematic review and meta-analysis of the validity of current technologies

Open access
O’Driscoll, Ruairi, Turicchi, Jake, Beaulieu, Kristine, Scott, Sarah, Matu, Jamie, Deighton, Kevin, Finlayson, Graham, Stubbs, James · 2020 · British Journal of Sports Medicine
Cited by 188

The DOI matches its Crossref record; 98 of the 98 references it cites were found in a registry or an index.

Abstract

Objective: To determine the accuracy of wrist and arm-worn activity monitors’ estimates of energy expenditure (EE). Data sources: SportDISCUS (EBSCOHost), PubMed, MEDLINE (Ovid), PsycINFO (EBSCOHost), Embase (Ovid) and CINAHL (EBSCOHost). Design: A random effects meta-analysis was performed to evaluate the difference in EE estimates between activity monitors and criterion measurements. Moderator analyses were conducted to determine the benefit of additional sensors and to compare the accuracy of devices used for research purposes with commercially available devices. Eligibility criteria: We included studies validating EE estimates from wrist-worn or arm-worn activity monitors against criterion measures (indirect calorimetry, room calorimeters and doubly labelled water) in healthy adult populations. Results: 60 studies (104 effect sizes) were included in the meta-analysis. Devices showed variable accuracy depending on activity type. Large and significant heterogeneity was observed for many devices (I 2 >75%). Combining heart rate or heat sensing technology with accelerometry decreased the error in most activity types. Research-grade devices were statistically more accurate for comparisons of total EE but less accurate than commercial devices during ambulatory activity and sedentary tasks. Conclusions: EE estimates from wrist and arm-worn devices differ in accuracy depending on activity type. Addition of physiological sensors improves estimates of EE, and research-grade devices are superior for total EE. These data highlight the need to improve estimates of EE from wearable devices, and one way this can be achieved is with the addition of heart rate to accelerometry. PROSPEROregistration number: CRD42018085016.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjsports-2018-099643

Cites

98 of 98 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 98 references

Research works printed but not linked: 2

  1. 10.1063/1.354123 · doi:10.1063/1.354123
  2. Brazeau, 2011, Accuracy of the SenseWear Armband™ during ergocycling, Int J Sports Med, 32, 761, 10.1055/s-0031-1279768 · doi:10.1055/s-0031-1279768

Cited by

Metadata

Authors
O’Driscoll, R., Turicchi, J., Beaulieu, K., Scott, S., Matu, J., Deighton, K., Finlayson, G., & Stubbs, J.
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
2018-09-07
Volume
54
Issue
6
Pages
332-340
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W2889930586
Cited by
188
References
98
FWCI
2.55
Type
journal article
Language
en
Open access
hybrid
Funders
University of Leeds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.