CoChat

Wrist-worn accelerometers: recommending ~1.0 m g as the minimum clinically important difference (MCID) in daily average acceleration for inactive adults

Open access

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Physical activity is increasingly assessed using wrist-worn accelerometry.1 The primary unit of measurement is acceleration which lacks an obvious concrete meaning in the clinical and public health settings. If the scientific community agreed on a minimum clinically important difference (MCID) that would greatly help users interpret accelerometry data in a more meaningful way. Here we present converging evidence to inform estimation of the MCID in physical activity for inactive adults, expressed as average acceleration measured from wrist-worn accelerometers. Contemporary accelerometers measure acceleration at high frequency in three axes. Typically, the Euclidean norm is calculated and 1 g subtracted to correct for gravity (Euclidean Norm Minus One (ENMO)). Average acceleration across the day is expressed in milli-gravitational units (m g ) and reflects overall daily activity, as does steps/day. Multiple days of measurement are usually summarised as daily average acceleration. Reflecting the value of capturing all physical activity across the whole day—rather than moderate-to-vigorous activity alone—average daily acceleration is an appropriate summary variable of physical activity status in most cases. Average daily acceleration is the recommended variable for physical activity analysis in UK Biobank, where >100 000 people wore a wrist-worn accelerometer for 7 days.1 We used three approaches to provide converging evidence for a preliminary estimate of the MCID in m g for ina…

Overview

Integrity signals

Registry

Crossref · 10.1136/bjsports-2020-102293

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 8 references

Cited by

See all 74

Metadata

Authors
Rowlands, A., Davies, M., Dempsey, P., Edwardson, C., Razieh, C., & Yates, T.
Affiliations
  • University of Leicester (GB)
  • Baker Heart and Diabetes Institute (AU)
Corresponding author
Rowlands, Alex
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
2020-09-14
Volume
55
Issue
14
Pages
814-815
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W3084731570
Cited by
74
References
8
Citations by year
2026: 8 · 2025: 14 · 2024: 16 · 2023: 11 · 2022: 16 · 2021: 9
FWCI
5.41
Type
journal article
Language
en
Open access
Licence
cc-by-nc
Locations
  • British Journal of Sports Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Figshare (submittedVersion, cc-by-nc)
Funders
  • Public Health Research Programme (16/41/04)
  • Department of Health Policy Research Programme (PR-R5-0213-25004)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
Keywords
wrist-worn accelerometers, minimal clinically important difference, physical activity, inactive adults, step count, cardiovascular morbidity, all-cause mortality, UK Biobank
MeSH terms
Acceleration, Adult, Humans, Wrist, Wrist Joint, Sedentary Behavior, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wrist-worn accelerometers: recommending ~1.0 m g as the minimum clinically important difference (MCID) in daily average acceleration for inactive adults. https://app.cochat.ai/papers/10.1136/bjsports-2020-102293
The paper
Rowlands, A., Davies, M., Dempsey, P., Edwardson, C., Razieh, C., & Yates, T. (2021). Wrist-worn accelerometers: recommending ~1.0 m g as the minimum clinically important difference (MCID) in daily average acceleration for inactive adults. British Journal of Sports Medicine. https://doi.org/10.1136/bjsports-2020-102293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.