CoChat

Can artificial intelligence pass the Fellowship of the Royal College of Radiologists examination? Multi-reader diagnostic accuracy study

Open access
Shelmerdine, Susan Cheng, Martin, Helena, Shirodkar, Kapil, Shamshuddin, Sameer, Weir-McCall, Jonathan Richard · 2022 · BMJ
Cited by 45

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective: To determine whether an artificial intelligence candidate could pass the rapid (radiographic) reporting component of the Fellowship of the Royal College of Radiologists (FRCR) examination. Design: Prospective multi-reader diagnostic accuracy study. Setting: United Kingdom. Participants: One artificial intelligence candidate (Smarturgences, Milvue) and 26 radiologists who had passed the FRCR examination in the preceding 12 months. Main outcome measures: Accuracy and pass rate of the artificial intelligence compared with radiologists across 10 mock FRCR rapid reporting examinations (each examination containing 30 radiographs, requiring 90% accuracy rate to pass). Results: When non-interpretable images were excluded from the analysis, the artificial intelligence candidate achieved an average overall accuracy of 79.5% (95% confidence interval 74.1% to 84.3%) and passed two of 10 mock FRCR examinations. The average radiologist achieved an average accuracy of 84.8% (76.1-91.9%) and passed four of 10 mock examinations. The sensitivity for the artificial intelligence was 83.6% (95% confidence interval 76.2% to 89.4%) and the specificity was 75.2% (66.7% to 82.5%), compared with summary estimates across all radiologists of 84.1% (81.0% to 87.0%) and 87.3% (85.0% to 89.3%). Across 148/300 radiographs that were correctly interpreted by >90% of radiologists, the artificial intelligence candidate was incorrect in 14/148 (9%). In 20/300 radiographs that most (>50%) radiologists interpreted incorrectly, the artificial intelligence candidate was correct in 10/20 (50%). Most imaging pitfalls related to interpretation of musculoskeletal rather than chest radiographs. Conclusions: When special dispensation for the artificial intelligence candidate was provided (that is, exclusion of non-interpretable images), the artificial intelligence candidate was able to pass two of 10 mock examinations. Potential exists for the artificial intelligence candidate to improve its radiographic interpretation skills by focusing on musculoskeletal cases and learning to interpret radiographs of the axial skeleton and abdomen that are currently considered “non-interpretable.”

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj-2022-072826

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 45

Metadata

Authors
Shelmerdine, S. C., Martin, H., Shirodkar, K., Shamshuddin, S., & Weir-McCall, J. R.
Venue
BMJ
Publisher
BMJ
Published
2022-12-21
Volume
379
Pages
e072826
ISSN
1756-1833 (ISSN-L)
OpenAlex
W4312067799
Cited by
45
References
3
FWCI
2.41
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Can artificial intelligence pass the Fellowship of the Royal College of Radiologists examination? Multi-reader diagnostic accuracy study. https://app.cochat.ai/papers/10.1136/bmj-2022-072826
The paper
Shelmerdine, S. C., Martin, H., Shirodkar, K., Shamshuddin, S., & Weir-McCall, J. R. (2022). Can artificial intelligence pass the Fellowship of the Royal College of Radiologists examination? Multi-reader diagnostic accuracy study. BMJ. https://doi.org/10.1136/bmj-2022-072826

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.