The DOI matches its Crossref record.
Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study.
Open accessAbstract
In a multicentre study of sepsis after total hip or knee replacement the operations performed by each surgeon were allocated at random between control and ultraclean-air operating rooms. Records were obtained from over 8000 such operations. In the patients whose prostheses were inserted in an operating room ventilated by an ultraclean-air system the incidence of joint sepsis confirmed at reoperation within the next one to four years was about half that of patients who had had the operation in a conventionally ventilated room at the same hospital. When whole-body exhaust-ventilated suits had been worn by the operating team in a theatre ventilated by an ultraclean-air system the incidence of sepsis was about a quarter of that found after operations performed with conventional ventilation. When all groups in the trial were considered together the analysis showed deep sepsis after 63 out of 4133 operations in the control group (1.5%) and after 23 out of 3922 operations in the ultraclean-air groups (0.6%) (ratio 2.6, 95% confidence limits 1.6-4.2; p less than 0.001). The design of the study did not include a strictly controlled test of the effect of prophylactic antibiotics, but their use was associated with a lower incidence of sepsis than in patients who had received no antibiotic prophylaxis at their operations (0.6% (34/5831) v 2.3% (52/2221); ratio 4.0).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guideline for Prevention of Surgical Site Infection, 1999
Mangram, A. J., Horan, T. C., Pearson, M. L., Silver, L. C., Jarvis, W. R., & The Hospital Infection Control Practices Advisory Committee (1999) · Infection Control & Hospital Epidemiology · doi:10.1086/501620 · Cited by 4,595
Phillips, J. E., Crane, T. P., Noy, M., Elliott, T. S. J., & Grimer, R. J. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b7.17150 · Cited by 513
Pathogenesis of foreign body infection. Evidence for a local granulocyte defect.
Zimmerli, W., Lew, P. D., & Waldvogel, F. A. (1984) · Journal of Clinical Investigation · doi:10.1172/jci111305 · Cited by 485
Environmental controls in operating theatres
Dharan, S., & Pittet, D. (2002) · Journal of Hospital Infection · doi:10.1053/jhin.2002.1217 · Cited by 282
Gosden, P. E., MacGowan, A. P., & Bannister, G. C. (1998) · Journal of Hospital Infection · doi:10.1016/s0195-6701(98)90255-9 · Cited by 118
Metadata
- Authors
- Lidwell, O. M., Lowbury, E. J., Whyte, W., Blowers, R., Stanley, S. J., & Lowe, D.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1982-07-03
- Volume
- 285
- Issue
- 6334
- Pages
- 10-14
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2124790551
- Cited by
- 696
- References
- 0
- FWCI
- 29.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. https://app.cochat.ai/papers/10.1136/bmj.285.6334.10
- The paper
- Lidwell, O. M., Lowbury, E. J., Whyte, W., Blowers, R., Stanley, S. J., & Lowe, D. (1982). Effect of ultraclean air in operating rooms on deep sepsis in the joint after total hip or knee replacement: a randomised study. BMJ. https://doi.org/10.1136/bmj.285.6334.10
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.