CoChat

Detection of arrhythmia: limited usefulness of patient activated recording devices.

Open access
Thomas, L E, Shapiro, L M, Perrins, E J, Fox, K M · 1984 · BMJ
Cited by 9

The DOI matches its Crossref record.

Abstract

The findings of 24 hour ambulatory electrocardiography and monitoring with the Cardiomemo, a device recording 32 seconds of electrocardiogram during symptoms, were compared in 20 patients with symptoms suggestive of arrhythmia. Ambulatory electrocardiography showed arrhythmia in seven patients, extrasystoles in six, and normal findings in seven. Nine patients failed to transmit any Cardiomemo recordings, and the Cardiomemo failed to show ventricular and supraventricular tachycardia. It did not show any appreciable arrhythmia in the seven patients with normal 24 hour electrocardiograms. The Cardiomemo does not offer any important advantages over ambulatory electrocardiography, and its relative cheapness is outweighed by the limited number of patients who can use the device in one year. It can, however, reassure anxious patients of the absence of arrhythmia during symptoms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.289.6452.1106

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 9

Metadata

Authors
Thomas, L. E., Shapiro, L. M., Perrins, E. J., & Fox, K. M.
Venue
BMJ
Publisher
BMJ
Published
1984-10-27
Volume
289
Issue
6452
Pages
1106-1107
ISSN
  • 0007-1447 (ISSN-L)
  • 1468-5833
OpenAlex
W1965989051
Cited by
9
References
0
FWCI
0.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detection of arrhythmia: limited usefulness of patient activated recording devices. https://app.cochat.ai/papers/10.1136/bmj.289.6452.1106
The paper
Thomas, L. E., Shapiro, L. M., Perrins, E. J., & Fox, K. M. (1984). Detection of arrhythmia: limited usefulness of patient activated recording devices. BMJ. https://doi.org/10.1136/bmj.289.6452.1106

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.