The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Abstract
The Holter monitor, the most frequently used diagnostic test in patients with syncope, is nondiagnostic in over 90% of cases. This study sought to determine the impact of a new noninvasive device, the cardiac loop electrocardiographic (ECG) recorder, after Holter monitoring in 57 patients with unexplained syncope. All patients underwent a standardized evaluation protocol and were the monitor for up to 1 month. In 14 patients, loop recording definitively determined whether an arrhythmia was the cause of symptoms (diagnostic yield 25%; 95% confidence intervals 14 to 38%). Diagnoses included unsuspected ventricular tachycardia (1 patient), high grade atrioventricular block (2 patients), supraventricular tachycardia (1 patient), asystole or junctional bradycardia from neurally mediated syncope (3 patients) and normal cardiac rhythms (the remaining 7 patients). Follow-up of all patients diagnosed as having nonarrhythmic syncope by loop recording showed that none of these patients died suddenly. Cardiac loop ECG recording is an important new diagnostic test in patients with syncope unexplained by Holter monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Linzer et al. reported that the diagnostic rate of Holter ECG for syncope was only about 10% [12].”
From Ambulatory electrocardiogram monitoring devices for evaluating transient loss of consciousness or other related symptoms (2017) · cites this paper as [12]
In the citing paper
“External loop recorders can be useful in patients with relatively frequent syncope episodes. 166-168”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [167]
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
In the citing paper
“Recent studies have shown that patient-triggered cardiac event recorders (CER) have an increased diagnostic yield and are more cost effective than conventional 24h-Holter electrocardiograms (ECGs) for the evaluation of sporadic, potentially arrhythmia-related symptoms.”
Citations
Cites
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
Almquist, A., Goldenberg, I. F., Milstein, S., Chen, M.-Y., Chen, X., Hansen, R., Gornick, C. C., & Benditt, D. G. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902093200603 · Cited by 651
Isoproterenol induction of vasodepressor-type reaction in vasodepressor-prone persons
Waxman, M. B., Yao, L., Cameron, D. A., Wald, R. W., & Roseman, J. (1989) · The American Journal of Cardiology · doi:10.1016/0002-9149(89)91076-x · Cited by 257
Patients With Syncope Admitted to Medical Intensive Care Units
Silverstein, M. D. (1982) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1982.03330100023024 · Cited by 256
Diagnostic efficacy of 24-hour electrocardiographic monitoring for syncope
Gibson, T. C., & Heitzman, M. R. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90628-3 · Cited by 229
Gulamhusein, S., Naccarelli, G. V., Ko, P. T., Prystowsky, E. N., Zipes, D. P., Barnett, H. J. M., Heger, J. J., & Klein, G. J. (1982) · The American Journal of Medicine · doi:10.1016/0002-9343(82)90413-2 · Cited by 177
Fujimura, O., Yee, R., Klein, G. J., Sharma, A. D., & Boahene, K. A. (1989) · New England Journal of Medicine · doi:10.1056/nejm198912213212503 · Cited by 158
Role of Cardiac Electrophysiologic Studies in Patients with Unexplained Recurrent Syncope
Akhtar, M., Shenasa, M., Denker, S. T., Gilbert, C. J., & RIZWI, N. (1983) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1983.tb04346.x · Cited by 131
The value of electrophysiologic studies in syncope of undetermined origin: Report of 150 cases
Teichman, S. L., Felder, S. D., Matos, J. A., Kim, S. G., Waspe, L. E., & Fisher, J. D. (1985) · American Heart Journal · doi:10.1016/0002-8703(85)90171-1 · Cited by 114
Brown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
Research works printed but not linked: 2
- Gendelman, 1983, Syncope in a general hospital patient population, NY State Med J, 83, 1161
- Westveer, 1984, The role of eleclrophysiologic studies in the evaluation of recurrent, unexplained syncope, Cardiovasc Rev Rep, 5, 770
Cited by
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Zipes, D. P., Camm, A. J., Borggrefe, M., Buxton, A. E., Chaitman, B., Fromer, M., Gregoratos, G., Klein, G., Myerburg, R. J., Quinones, M. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.07.010 · Cited by 1,973
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Al-Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,854
Incidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364
Metadata
- Authors
- Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W.
- Affiliations
- Duke Medical Center (US)
- Duke University (US)
- Corresponding author
- Linzer, Mark
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1990-07
- Volume
- 66
- Issue
- 2
- Pages
- 214-219
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W2066071317
- Semantic Scholar
- 7b7fdf3a51f4893b64f1f600a91f1c4149d231a8
- Cited by
- 239
- References
- 23
- Citations by year
- 2026: 2 · 2023: 1 · 2022: 5 · 2021: 5 · 2020: 6 · 2019: 2 · 2018: 10 · 2017: 15 · 2016: 3 · 2015: 5 · 2014: 9 · 2013: 10 · 2012: 5
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (1r01hl040392-01a1, 2s07rr005405-30)
- National Heart, Lung, and Blood Institute (HL24920, HL40392)
- National Center for Research Resources (S07-RR-05405)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Keywords
- unexplained syncope, Holter monitoring, diagnostic yield, cardiac arrhythmias, neurally mediated syncope, ventricular tachycardia, atrioventricular block, supraventricular tachycardia, asystole, sudden cardiac death
- MeSH terms
- Arrhythmias, Cardiac, Female, Follow-Up Studies, Humans, Male, Middle Aged, Patient Compliance, Prospective Studies, Syncope, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope. https://app.cochat.ai/papers/10.1016/0002-9149(90)90591-n
- The paper
- Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990). Incremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope. The American Journal of Cardiology. https://doi.org/10.1016/0002-9149(90)90591-n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.