CoChat

Randomised controlled trial of computer assisted management of hypertension in primary care.

Open access
McAlister, N H, Covvey, H D, Tong, C, Lee, A, Wigle, E D · 1986 · BMJ
Cited by 84

The DOI matches its Crossref record.

Abstract

The hypothesis that general practitioners would obtain better outcomes for patients with hypertension using a computer than doctors not using a computer was tested. Sixty family physicians were randomised to two treatment strategies. "Test" physicians completed a data collection form after each visit from a patient with hypertension and mailed the forms to the test centre for processing. Computer feedback on management was mailed to the doctors. This encouraged doctors to apply the "stepped care" protocol, supplied charts of diastolic blood pressure v time, and ranked patients' diastolic blood pressures by percentile. Letters were mailed to patients to remind them of appointments. "Control" doctors filled out the same data collection forms as test physicians, but neither doctors nor patients received computer feedback. Physicians who used the computer saw more patients per practice than control doctors (test 50 patients, control 40). For all patients the length of follow up was significantly longer in test practices (test 199 days, control 167), and a smaller percentage dropped out of active treatment in test practices (test 37.5%, control 42.1%). For patients with "moderate" hypertension of a baseline diastolic pressure of greater than 104 mm Hg the mean score of the last recorded pressure was below the goal of 90 mm Hg in test practices (88.5 mm Hg), but it failed to reach this goal in control practices (93.3 mm Hg). A greater average reduction of diastolic pressure was achieved in test practices (test 21.7 mm Hg, control 16.7 mm Hg). Though patients with "moderate" hypertension were better controlled in test practices than in control practices, the patients in test practices visited their doctors less often (test 13.3 visits per patient-year, control 17.4 visits). Among patients with newly detected hypertension test practices achieved a greater reduction in diastolic pressure than control practices (test 15.1 mm Hg v control 11.3 mm Hg) and more sustained control of hypertension (test 323 days per patient-year with a diastolic pressure of 90 mm Hg or less v control 259 days).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.293.6548.670

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
McAlister, N. H., Covvey, H. D., Tong, C., Lee, A., & Wigle, E. D.
Venue
BMJ
Publisher
BMJ
Published
1986-09-13
Volume
293
Issue
6548
Pages
670-674
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2055114234
Cited by
84
References
0
FWCI
0.99
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.