The DOI matches its Crossref record.
Maternal serum screening for Down's syndrome in early pregnancy.
Open accessAbstract
The possibility of improving the effectiveness of antenatal screening for Down's syndrome by measuring human chorionic gonadotrophin concentrations in maternal serum during the second trimester to select women for diagnostic amniocentesis was examined. The median maternal serum human chorionic gonadotrophin concentration in 77 pregnancies associated with Down's syndrome was twice the median concentration in 385 unaffected pregnancies matched for maternal age, gestational age, and duration of storage of the serum sample. Measuring human chorionic gonadotrophin in maternal serum was an effective screening test, giving a lower false positive rate (3%) at a 30% detection rate than that for maternal age (5%) and the two existing serum screening tests, unconjugated oestriol (7%) and alpha fetoprotein (11%). The most effective screening results were obtained with all four variables combined; at the same 30% detection rate the false positive rate declined to 0.5%. The new screening method would detect over 60% of affected pregnancies, more than double that achievable with the same amniocentesis rate in existing programmes (5%), and could reduce the number of children born with Down's syndrome in the United Kingdom from about 900 a year to about 350 a year.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Wald, N. J., Rodeck, C., Hackshaw, A. K., Walters, J., Chitty, L., & Mackinson, A. M. (2003) · Health Technology Assessment · doi:10.3310/hta7110 · Cited by 585
Self-citationRose's Strategy of Preventive Medicine
Rose, G., Khaw, K.-T., & Marmot, M. (2008) · doi:10.1093/acprof:oso/9780192630971.001.0001 · Cited by 490
Prenatal Screening for Down's Syndrome with Use of Maternal Serum Markers
Haddow, J. E., Palomaki, G. E., Knight, G. J., Williams, J., Pulkkinen, A., Canick, J. A., Saller, D. N., & Bowers, G. B. (1992) · New England Journal of Medicine · doi:10.1056/nejm199208273270902 · Cited by 454
Self-citationAntenatal Screening for Down's Syndrome
Wald, N. J., Kennard, A., Hackshaw, A., & McGuire, A. (1997) · Journal of Medical Screening · doi:10.1177/096914139700400402 · Cited by 406
Self-citation
Metadata
- Authors
- Wald, N. J., Cuckle, H. S., Densem, J. W., Nanchahal, K., Royston, P., Chard, T., Haddow, J. E., Knight, G. J., Palomaki, G. E., & Canick, J. A.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1988-10-08
- Volume
- 297
- Issue
- 6653
- Pages
- 883-887
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2085809389
- Cited by
- 966
- References
- 0
- FWCI
- 57.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Maternal serum screening for Down's syndrome in early pregnancy. https://app.cochat.ai/papers/10.1136/bmj.297.6653.883
- The paper
- Wald, N. J., Cuckle, H. S., Densem, J. W., Nanchahal, K., Royston, P., Chard, T., Haddow, J. E., Knight, G. J., Palomaki, G. E., & Canick, J. A. (1988). Maternal serum screening for Down's syndrome in early pregnancy. BMJ. https://doi.org/10.1136/bmj.297.6653.883
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.