Carrier solutions for low-level intravenous insulin infusion.
Open accessThe DOI matches its Crossref record.
Abstract
In the use of low-level intravenous insulin infusion for treating diabetic hyperglycaemia and ketoacidosis adsorption of insulin to containers or plastic infusion apparatus results in significant losses of 60-80% of insulin in dilute physiological saline solution (40 U/l). It is therefore necessary to add protein to the carrier solution to minimize losses and maintain a constant delivery rate. Recovery studies showed that 3.5% w/v polygeline solution (polymer of degraded gelatin) was a suitable medium for this purpose, offering some advantages over human serum albumin. A minimum concentration of 0.5% polygeline was required to ensure adequate delivery of insulin to the patient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kisspeptin-54 stimulates the hypothalamic-pituitary gonadal axis in human males
Dhillo, W. S., Chaudhri, O. B., Patterson, M., Thompson, E. L., Murphy, K. G., Badman, M. K., McGowan, B. M., Amber, V., Patel, S., Ghatei, M. A., et al. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1468 · Cited by 656
Tan, T. M., Field, B. C. T., McCullough, K. A., Troke, R. C., Chambers, E. S., Salem, V., Gonzalez Maffe, J., Baynes, K. C. R., De Silva, A., Viardot, A., et al. (2013) · Diabetes · doi:10.2337/db12-0797 · Cited by 258
Coinfusion of low-dose GLP-1 and glucagon in man results in a reduction in food intake
Cegla, J., Troke, R. C., Jones, B., Tharakan, G., Kenkre, J., McCullough, K. A., Lim, C. T., Parvizi, N., Hussein, M., Chambers, E. S., et al. (2014) · Diabetes · doi:10.2337/db14-0242 · Cited by 159
Tan, T., Behary, P., Tharakan, G., Minnion, J., Al-Najim, W., Albrechtsen, N. J. W., Holst, J. J., & Bloom, S. R. (2017) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2017-00469 · Cited by 88
“Gelofusine was used to prime the syringes and tubing prior to use to prevent adsorption of the peptides to tubing (27); however, the peptides were reconstituted in 0.”
Method
Metadata
- Authors
- Kraegen, E. W., Lazarus, L., Meler, H., Campbell, L., & Chia, Y. O.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1975-08-23
- Volume
- 3
- Issue
- 5981
- Pages
- 464-466
- ISSN
- 0007-1447 (ISSN-L)
- 1468-5833
- OpenAlex
- W2036542119
- Cited by
- 75
- References
- 0
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Carrier solutions for low-level intravenous insulin infusion. https://app.cochat.ai/papers/10.1136/bmj.3.5981.464
- The paper
- Kraegen, E. W., Lazarus, L., Meler, H., Campbell, L., & Chia, Y. O. (1975). Carrier solutions for low-level intravenous insulin infusion. BMJ. https://doi.org/10.1136/bmj.3.5981.464
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.