Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 203

The DOI matches its Crossref record.

Loop diathermy excision of the cervical transformation zone in patients with abnormal cervical smears.

Open access
Luesley, D M, Cullimore, J, Redman, C W, Lawton, F G, Emens, J M, Rollason, T P, Williams, D R, Buxton, E J·1990·BMJ

Abstract

OBJECTIVE--To determine the efficacy and morbidity of fine loop diathermy excision of the cervical transformation zone as applied to the management of outpatients with abnormal cervical smears. DESIGN--Prospective programme trial with six month follow up. SETTING--Two hospital based colposcopy clinics. PATIENTS--616 Patients aged 16-60 with abnormal cervical smears. INTERVENTIONS--After colposcopic and cytological assessment excision of the cervical transformation zone by fine loop diathermy under local anaesthesia in the outpatient department. MAIN OUTCOME MEASURES--Time to complete the treatment, immediate morbidity in terms of discomfort and bleeding, and cytological and colposcopic findings at six months. RESULTS--Treatment was completed in a mean of 3.47 minutes (SD 1.99). Immediate morbidity was minimal, and histological specimens were adequate in over 90% of cases. Almost two thirds of patients were treated at their first visit to the clinic. 58 Patients (9.4%) failed to attend for follow up at six months and one had had a hysterectomy. Of the 557 patients who attended for colposcopic and cytological follow up at six months, 506 (91%) were normal cytologically and 19 (3.4%) had histologically confirmed persistence of cervical intraepithelial neoplasia. The overall confirmed failure rate of the technique was 4.4%. CONCLUSION--Loop diathermy excision is an effective treatment with low morbidity and is an appropriate modality for patients with abnormal cervical smears.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.300.6741.1690

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 203

Metadata

Authors
Luesley, D. M., Cullimore, J., Redman, C. W., Lawton, F. G., Emens, J. M., Rollason, T. P., Williams, D. R., & Buxton, E. J.
Venue
BMJ
Publisher
BMJ
Published
1990-06-30
Volume
300
Issue
6741
Pages
1690-1693
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W1998907696
Cited by
203
References
0
FWCI
12.59
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Loop diathermy excision of the cervical transformation zone in patients with abnormal cervical smears. https://app.cochat.ai/papers/10.1136/bmj.300.6741.1690
The paper
Luesley, D. M., Cullimore, J., Redman, C. W., Lawton, F. G., Emens, J. M., Rollason, T. P., Williams, D. R., & Buxton, E. J. (1990). Loop diathermy excision of the cervical transformation zone in patients with abnormal cervical smears. BMJ. https://doi.org/10.1136/bmj.300.6741.1690

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.