Using fasting plasma glucose concentrations to screen for gestational diabetes mellitus: prospective population based study
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Abstract Objective: To evaluate whether measuring fasting plasma glucose concentration is an easier screening procedure for gestational diabetes mellitus than the 1 hour 50 g glucose challenge test. Design: Prospective population based study. Setting: Outpatient clinic in a university hospital. Participants: 520 pregnant women (328 (63%) white, 99 (19%) Asian, 31 (6%) African, 62 (12%) others) with mean age 28.4 (SD 0.2; range 17-45) years. All underwent a glucose challenge test between the 24th and 28th gestational week, followed by a diagnostic 3 hour 100 g oral glucose tolerance test within one week. This was done irrespective of the result of the challenge test. Main outcome measure: Receiver operating curves were used to determine the best cut off values for screening with fasting plasma glucose concentrations. Results: Fasting plasma glucose concentration at a threshold value of 4.8 mmol/l and the glucose challenge test with a threshold value of 7.8 mmol/l yielded sensitivities of 81% and 59% respectively and specificities of 76% and 91% respectively. Measuring fasting plasma glucose concentration as a screening procedure required a diagnostic test in 30%, compared with 14% when the challenge test was used. Conclusions: Measuring fasting plasma glucose concentrations using a cut off value of ≥4.8 mmol/l is an easier screening procedure for gestational diabetes than the 50 g glucose challenge test and allows 70% of women to avoid the challenge test. Key messages Identifying women susceptible to gestational diabetes is particularly important not only to prevent perinatal morbidity but also to improve long term outcomes for the mother and her child Measuring fasting plasma glucose concentration is an easier screening procedure for gestational diabetes than the 1 hour 50 g glucose challenge test With a threshold value of 4.8 mmol/l it yields a sensitivity of 81% and a specificity of 76% Measuring fasting plasma glucose concentration allows 70% of women to avoid a glucose challenge test
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Report of the Expert Committee on the Diagnosis and Classification of Diabetes Mellitus
The Expert Committee on the Diagnosis and Classification of Diabetes Mellitus (1997) · Diabetes Care · doi:10.2337/diacare.20.7.1183 · Cited by 6,220
Criteria for screening tests for gestational diabetes
Carpenter, M. W., & Coustan, D. R. (1982) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(82)90349-0 · Cited by 1,924
Silverman, B. L., Metzger, B. E., Cho, N. H., & Loeb, C. A. (1995) · Diabetes Care · doi:10.2337/diacare.18.5.611 · Cited by 643
Mooy, J. M., Grootenhuis, P. A., de Vries, H., Kostense, P. J., Popp-Snijders, C., Bouter, L. M., & Heine, R. J. (1996) · Diabetologia · doi:10.1007/bf00418345 · Cited by 344
Cited by
Different strategies for diagnosing gestational diabetes to improve maternal and infant health
Farrar, D., Duley, L., Dowswell, T., & Lawlor, D. A. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007122.pub4 · Cited by 153
Donovan, L., Hartling, L., Muise, M., Guthrie, A., Vandermeer, B., & Dryden, D. M. (2013) · Annals of Internal Medicine · doi:10.7326/0003-4819-159-2-201307160-00657 · Cited by 125
Glucose challenge test for detecting gestational diabetes mellitus: a systematic review
van Leeuwen, M., Louwerse, M., Opmeer, B., Limpens, J., Serlie, M., Reitsma, J., & Mol, B. (2012) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2011.03254.x · Cited by 110
RETIRED: Screening for Gestational Diabetes Mellitus
(2002) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)31047-7 · Cited by 100
Different strategies for diagnosing gestational diabetes to improve maternal and infant health
Farrar, D., Duley, L., Medley, N., & Lawlor, D. A. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007122.pub3 · Cited by 56
Metadata
- Authors
- Perucchini, D., Fischer, U., Spinas, G. A., Huch, R., Huch, A., & Lehmann, R.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1999-09-25
- Volume
- 319
- Issue
- 7213
- Pages
- 812-815
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2046097524
- Cited by
- 124
- References
- 4
- FWCI
- 7.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Using fasting plasma glucose concentrations to screen for gestational diabetes mellitus: prospective population based study. https://app.cochat.ai/papers/10.1136/bmj.319.7213.812
- The paper
- Perucchini, D., Fischer, U., Spinas, G. A., Huch, R., Huch, A., & Lehmann, R. (1999). Using fasting plasma glucose concentrations to screen for gestational diabetes mellitus: prospective population based study. BMJ. https://doi.org/10.1136/bmj.319.7213.812
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.