Biochemical diagnosis of ventricular dysfunction in elderly patients in general practice: observational study
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: To investigate the usefulness of measuring plasma concentrations of B type natriuretic peptide in the diagnosis of left ventricular systolic dysfunction in an unselected group of elderly people. DESIGN: Observational study. SETTING: General practice with four centres in Poole, Dorset. PARTICIPANTS: 155 elderly patients aged 70 to 84 years. MAIN OUTCOME MEASURES: Diagnostic characteristics of plasma B type natriuretic peptide measured by radioimmunoassay as a test for left ventricular systolic dysfunction assessed by echocardiography. RESULTS: The median plasma concentration of B type natriuretic peptide was 39.3 pmol/l in patients with left ventricular systolic dysfunction and 15.8 pmol/l in those with normal function. The proportional area under the receiver operator curve was 0.85. At a cut-off point of 18.7 pmol/l the test sensitivity was 92% and the predictive value 18%. CONCLUSIONS: Plasma concentration of B type natriuretic peptide could be used effectively as an initial test in a community screening programme and, possibly, using a low cut-off point, as a means of ruling out left ventricular systolic dysfunction. It is, however, not a good test to "rule in" the diagnosis, and access to echocardiography remains essential for general practitioners to diagnose heart failure early.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
Plasma brain natriuretic peptide concentration: impact of age and gender
Redfield, M. M., Rodeheffer, R. J., Jacobsen, S. J., Mahoney, D. W., Bailey, K. R., & Burnett, J. C. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02059-4 · Cited by 1,138
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
“(37) Test results can be truly dichotomous (e.”
Case–Control and Two-Gate Designs in Diagnostic Accuracy Studies
Rutjes, A. W., Reitsma, J. B., Vandenbroucke, J. P., Glas, A. S., & Bossuyt, P. M. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.048595 · Cited by 501
Mant, J., Doust, J., Roalfe, A., Barton, P., Cowie, M., Glasziou, P., Mant, D., McManus, R., Holder, R., Deeks, J., et al. (2009) · Health Technology Assessment · doi:10.3310/hta13320 · Cited by 498
Metadata
- Authors
- Smith, H.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2000-04-01
- Volume
- 320
- Issue
- 7239
- Pages
- 906-908
- ISSN
- 0959-8138 (ISSN-L)
- OpenAlex
- W2087170893
- Cited by
- 98
- References
- 0
- FWCI
- 8.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Biochemical diagnosis of ventricular dysfunction in elderly patients in general practice: observational study. https://app.cochat.ai/papers/10.1136/bmj.320.7239.906
- The paper
- Smith, H. (2000). Biochemical diagnosis of ventricular dysfunction in elderly patients in general practice: observational study. BMJ. https://doi.org/10.1136/bmj.320.7239.906
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.