The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Microbubble contrast agents: a new era in ultrasound
Open accessAbstract
Contrast agents are widely used in imaging, but until recently they had little place in ultrasonography. This has changed with the introduction of microbubbles—small (typically 3 μm in diameter) gas filled bubbles that are usually injected intravenously. Injecting a gas into the circulation may seem potentially hazardous, but extensive clinical experience has shown that the tiny volume of air or gas given (under 200 μl) is not dangerous, and the safety of microbubbles compares well to that of conventional agents in radiography and magnetic resonance imaging.1 Although microbubbles were originally designed simply to improve conventional ultrasound scanning, recent discoveries have opened up powerful emerging applications. This article describes some of these applications in radiology and cardiology and discusses the potential of microbubbles for therapy. We prepared this review from contributions from researchers with special knowledge of the use of microbubbles in radiology, cardiology, and treatment. We combined our personal experience in research over several years with a review of recent literature on the subject. Microbubbles work by resonating in an ultrasound beam, rapidly contracting and expanding in response to the pressure changes of the sound wave. By a fortunate coincidence, they vibrate particularly strongly at the high frequencies used for diagnostic ultrasound imaging. This makes them several thousand times more reflective than normal body tissues. In this way they enhance both grey scale images and flow mediated Doppler signals. As well as being useful in itself, the resonance that microbubbles produce has several special properties that can be exploited to improve diagnoses. Just as with a musical instrument, multiple harmonic signals—or overtones—are produced. Ultrasound scanners can be tuned to “listen” to these harmonics, producing strong preferential imaging of the microbubbles in an image. The selective excitation produced can also destroy microbubbles relatively easily, an effect that can be useful …
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
Echocardiographic Destruction of Albumin Microbubbles Directs Gene Delivery to the Myocardium
Shohet, R. V., Chen, S., Zhou, Y.-T., Wang, Z., Meidell, R. S., Unger, R. H., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.101.22.2554 · Cited by 446
Price, R. J., Skyba, D. M., Kaul, S., & Skalak, T. C. (1998) · Circulation · doi:10.1161/01.cir.98.13.1264 · Cited by 393
Contrast Echocardiography: Current and Future Applications
Mulvagh, S. L., DeMaria, A. N., Feinstein, S. B., Burns, P. N., Kaul, S., Miller, J. G., Monaghan, M., Porter, T. R., Shaw, L. J., & Villanueva, F. S. (2000) · Journal of the American Society of Echocardiography · doi:10.1067/mje.2000.105462 · Cited by 310
Self-citationCohen, J. L., Cheirif, J., Segar, D. S., Gillam, L. D., Gottdiener, J. S., Hausnerova, E., & Bruns, D. E. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00311-8 · Cited by 297
Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent
Albrecht, T., Blomley, M. J., Cosgrove, D. O., Taylor-Robinson, S. D., Jayaram, V., Eckersley, R., Urbank, A., Butler-Barnes, J., & Patel, N. (1999) · The Lancet · doi:10.1016/s0140-6736(98)06373-9 · Cited by 246
Self-citationTissue-Specific US Contrast Agent for Evaluation of Hepatic and Splenic Parenchyma
Forsberg, F., Goldberg, B. B., Liu, J., Merton, D. A., Rawool, N. M., & Shi, W. T. (1999) · Radiology · doi:10.1148/radiology.210.1.r99ja11125 · Cited by 103
Gene transfection and drug delivery
Miller, M. W. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00166-6 · Cited by 90
Strandell, A., Bourne, T., Bergh, C., Granberg, S., Asztély, M., & Thorburn, J. (1999) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1999.14030200.x · Cited by 82
Science, medicine, and the future : Gene therapy
Russell, S. J. (1997) · BMJ · doi:10.1136/bmj.315.7118.1289 · Cited by 33
Cited by
Imaging and drug delivery using theranostic nanoparticles
Janib, S. M., Moses, A. S., & MacKay, J. A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.08.004 · Cited by 1,248
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Schutt, E. G., Klein, D. H., Mattrey, R. M., & Riess, J. G. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200200550 · Cited by 543
Mechanical Force-Triggered Drug Delivery
Zhang, Y., Yu, J., Bomba, H. N., Zhu, Y., & Gu, Z. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00369 · Cited by 354
Lan, H. Y., Mu, W., Tomita, N., Huang, X. R., Li, J. H., Zhu, H.-J., Morishita, R., & Johnson, R. J. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000067632.04658.b8 · Cited by 344
Metadata
- Authors
- Blomley, M. J. K., Cooke, J. C., Unger, E. C., Monaghan, M. J., & Cosgrove, D. O.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2001-05-19
- Volume
- 322
- Issue
- 7296
- Pages
- 1222-1225
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W1577694822
- Cited by
- 426
- References
- 10
- FWCI
- 14.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbubble contrast agents: a new era in ultrasound. https://app.cochat.ai/papers/10.1136/bmj.322.7296.1222
- The paper
- Blomley, M. J. K., Cooke, J. C., Unger, E. C., Monaghan, M. J., & Cosgrove, D. O. (2001). Microbubble contrast agents: a new era in ultrasound. BMJ. https://doi.org/10.1136/bmj.322.7296.1222
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.