Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 171

The DOI matches its Crossref record.

Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressure

Open access
Little, Paul, Barnett, Jane, Barnsley, Lucy, Marjoram, Jean, Fitzgerald-Barron, Alex, Mant, David·2002·BMJ

Abstract

Objective : To assess alternatives to measuring ambulatory pressure, whichbest predicts response to treatment and adverse outcome. Setting : Three general practices in England Design : Validation study Participants : Patients with newly diagnosed high or borderline high bloodpressure; patients receiving treatment for hypertension but with poor control. Main outcome measures : Overall agreement with ambulatory pressure; prediction of high ambulatory pressure (>135/85 mm Hg) and treatment thresholds. Results : Readings made by doctors were much higher than ambulatory systolic pressure (difference 18.9 mm Hg, 95% confidence interval 16.1 to 21.7), as were recentreadings made in the clinic outside research settings (19.9 mm Hg,17.6 to 22.1). This applied equally to treated patients with poor control (doctor v ambulatory21.4 mm Hg, 17.3 to 25.4). Doctors' and recent clinic readings ranked systolic pressure poorly compared with ambulatory pressure and other measurements (doctor r =0.46; clinic 0.47; repeated readings by nurse 0.60; repeated self measurement 0.73; home readings 0.75) and were not specific at predicting high blood pressure(doctor 26%; recent clinic 15%; nurse 72%; patient in surgery 81%; home 60%), with poor likelihood ratios for a positive test (doctor 1.2; clinic 1.1; nurse 2.1, patient in surgery 4.7; home 2.2). Nor were doctor or recent clinic measures specific in predicting treatment thresholds. Conclusion : The “white coat” effect is important in diagnosing and assessing control of hypertension in primary care and is not a research artefact. If ambulatory or home measurements are not available, repeated measurements by the nurse or patient should result in considerably less unnecessary monitoring, initiation, or changing of treatment. It is time to stop using high blood pressure readings documented by general practitioners to make treatment decisions

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.325.7358.254

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 171

Metadata

Authors
Little, P., Barnett, J., Barnsley, L., Marjoram, J., Fitzgerald-Barron, A., & Mant, D.
Venue
BMJ
Publisher
BMJ
Published
2002-08-03
Volume
325
Issue
7358
Pages
254
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2041631374
Cited by
171
References
0
FWCI
12.66
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressure. https://app.cochat.ai/papers/10.1136/bmj.325.7358.254
The paper
Little, P., Barnett, J., Barnsley, L., Marjoram, J., Fitzgerald-Barron, A., & Mant, D. (2002). Comparison of agreement between different measures of blood pressure in primary care and daytime ambulatory blood pressure. BMJ. https://doi.org/10.1136/bmj.325.7358.254

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.