Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 209

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Use of automated external defibrillator by first responders in out of hospital cardiac arrest: prospective controlled trial

Open access
van Alem, Anouk P, Vrenken, Rob H, de Vos, Rien, Tijssen, Jan G P, Koster, Rudolph W · 2003 · BMJ

Abstract

Objective To test the hypothesis that the use of an automated external defibrillator by police and fire fighters results in higher discharge rates for out of hospital cardiac arrest. Design Controlled clinical trial with initial random allocation of automated external defibrillators to first responders in four of the eight participating regions; each region switched from control to experimental, and vice versa, every four months. Setting Amsterdam and surroundings, the Netherlands. Participants Patients with witnessed out of hospital cardiac arrests, identified by the emergency medical system between January 2000 and January 2002. Main outcomes measures Survival to hospital discharge; return of spontaneous circulation; admission to hospital. Results 243 patients (65% in ventricular fibrillation) were included in the experimental area and 226 patients (67% in ventricular fibrillation) in the control area. The median time interval between collapse and first shock was 668 seconds in the experimental area and 769 seconds in the control area (P < 0.001). 44 (18%) patients in the experimental area versus 33 (15%) patients in the control area were discharged (odds ratio 1.3 (95% confidence interval 0.8 to 2.2), P = 0.33), 139 (57%) experimental versus 108 (48%) control patients had return of spontaneous circulation (1.5 (1.0 to 2.2), P = 0.05), and 103 (42%) experimental versus 74 (33%) control patients were admitted (1.5 (1.1 to 1.6), P = 0.02). The median delay from receipt of call to dispatch of the ambulance was 120 seconds, and the delay to dispatch of the first responder was 180 seconds. Conclusions Use of automated external defibrillators by first responders did not significantly increase survival to discharge from hospital, although it did improve return of spontaneous circulation and admission to hospital. Improved dispatch procedures should increase the success of programmes of first responders using external defibrillators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.327.7427.1312

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 209

Metadata

Authors
van Alem, A. P., Vrenken, R. H., de Vos, R., Tijssen, J. G. P., & Koster, R. W.
Venue
BMJ
Publisher
BMJ
Published
2003-12-04
Volume
327
Issue
7427
Pages
1312
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2165465814
Cited by
209
References
2
FWCI
17.57
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Use of automated external defibrillator by first responders in out of hospital cardiac arrest: prospective controlled trial. https://app.cochat.ai/papers/10.1136/bmj.327.7427.1312
The paper
van Alem, A. P., Vrenken, R. H., de Vos, R., Tijssen, J. G. P., & Koster, R. W. (2003). Use of automated external defibrillator by first responders in out of hospital cardiac arrest: prospective controlled trial. BMJ. https://doi.org/10.1136/bmj.327.7427.1312

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.