How to measure renal function in clinical practice
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The reliable measurement of renal excretory function is of great importance in clinical practice and in research. The introduction of routine reporting of estimated glomerular filtration rate and a new definition of chronic kidney disease has renewed interest in methods of measuring renal function. Coupled with this is the fact that several countries are moving towards population screening for renal impairment to try to reduce the associated increased cardiovascular risk. Accurate measurement is methodologically difficult so surrogate measures such as serum creatinine levels and prediction formulas (based on factors such as the patient's age, sex, and serum creatinine level) are more commonly used in routine practice. We describe routine and more specialised methods of assessing renal function and discuss estimated glomerular filtration rate. The kidney has several interlinked functions (box). These depend on glomerular filtration rate, the unit measure of kidney function. Glomerular filtration rate can be defined as the volume of plasma cleared of an ideal substance per unit of time (usually expressed as ml/min). The ideal substance is one that is freely filtered at the glomerulus and neither secreted nor reabsorbed by the renal tubules. Creatinine is the closest to an ideal endogenous substance for measuring glomerular filtration rate.w1 Plasma creatinine is almost exclusively a product of the metabolism of creatine and phosphocreatine in skeletal muscle, although ingestion of meat may also contribute slightly.w2 w3 In patients with stable renal function, serum creatinine levels are usually constant, with variability daily of about only 8%.w4 w5 Creatinine is freely filtered at the glomerulus and is not reabsorbed, but up to 15% is actively secreted by the tubules.w6 In advanced renal failure, excretion of creatinine through the gastrointestinal tract increases.w7 Measuring the creatinine clearance using serum creatinine level and a timed urine collection gives an …
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prediction of Creatinine Clearance from Serum Creatinine
Cockcroft, D. W., & Gault, H. (1976) · Nephron · doi:10.1159/000180580 · Cited by 15,309
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079
Klahr, S., Levey, A. S., Beck, G. J., Caggiula, A. W., Hunsicker, L., Kusek, J. W., & Striker, G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199403313301301 · Cited by 2,328
(2000) · Journal of the American Society of Nephrology · Cited by 1,718
Peterson, J. C., Adler, S., Burkart, J. M., Greene, T., Hebert, L. A., Hunsicker, L. G., King, A. J., Klahr, S., Massry, S. G., Seifter, J. L., et al. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-123-10-199511150-00003 · Cited by 1,342
Coresh, J., Astor, B. C., McQuillan, G., Kusek, J., Greene, T., Van Lente, F., & Levey, A. S. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32765 · Cited by 717
Glomerular filtration rate measurement in man by the single injection methods using 51Cr-EDTA.
CHANTLER, C., Garnett, E. S., Parsons, V., & Veall, N. (1969) · PubMed · Cited by 432
Verhave, J. C., Fesler, P., Ribstein, J., du Cailar, G., & Mimran, A. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.05.011 · Cited by 386
Plasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate.
Gaspari, F., Perico, N., Ruggenenti, P., Mosconi, L., Amuchastegui, C. S., Guerini, E., Daina, E., & Remuzzi, G. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v62257 · Cited by 375
Levey, A. S., Adler, S., Caggiula, A. W., England, B. K., Greene, T., Hunsicker, L. G., Kusek, J. W., Rogers, N. L., & Teschan, P. E. (1996) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(96)90099-2 · Cited by 334
Estimating kidney function in adults using formulae
Lamb, E. J., Tomson, C. R., & Roderick, P. J. (2005) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/0004563054889936 · Cited by 238
Biological variation of cystatin C: implications for the assessment of glomerular filtration rate
Keevil, B. G., Kilpatrick, E. S., Nichols, S. P., & Maylor, P. W. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.7.1535 · Cited by 232
Application of GFR-estimating equations in Chinese patients with chronic kidney disease
Zuo, L., Ma, Y.-C., Zhou, Y.-H., Wang, M., Xu, G.-B., & Wang, H.-Y. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2004.11.012 · Cited by 202
MDRD Equations for Estimation of GFR in Renal Transplant Recipients
Pöge, U., Gerhardta, T., Palmedo, H., Klehr, H.-U., Sauerbruch, T., & Woitas, R. P. (2005) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2005.00861.x · Cited by 187
Pierrat, A., Gravier, E., Saunders, C., Caira, M.-V., Aït-Djafer, Z., Legras, B., & Mallié, J.-P. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00208.x · Cited by 174
Precision of plasma clearance of iohexol for estimation of GFR in patients with renal disease.
Gaspari, F., Perico, N., Matalone, M., Signorini, O., Azzollini, N., Mister, M., & Remuzzi, G. (1998) · Journal of the American Society of Nephrology · doi:10.1681/asn.v92310 · Cited by 161
Israelit, A. H., Long, D. L., White, M. G., & Hull, A. R. (1973) · Kidney International · doi:10.1038/ki.1973.127 · Cited by 159
Current status on assessment and measurement of glomerular filtration rate
Brøchner‐Mortensen, J. (1985) · Clinical Physiology · doi:10.1111/j.1475-097x.1985.tb00742.x · Cited by 136
Biesen, W. V., Vanholder, R. C., Veys, N., Verbeke, F., Delanghe, J., Bacquer, D. D., & Lameire, N. (2005) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi185 · Cited by 118
(1996) · Journal of the American Society of Nephrology · doi:10.1681/asn.v7122616 · Cited by 78
Mahajan, S., Mukhiya, G. K., Singh, R., Tiwari, S. C., Kalra, V., Bhowmik, D. M., Gupta, S. K., Agarwal, S. K., & Dash, S. C. (2005) · Journal of Nephrology · doi:10.1093/joneph/18.3.257 · Cited by 66
BDNF Acutely Modulates Synaptic Transmission and Calcium Signalling in Developing Cortical Neurons
He, J., Gong, H., & Luo, Q. (2005) · Cellular Physiology and Biochemistry · doi:10.1159/000087733 · Cited by 55
Anandarajah, S., Tai, T. W., de Lusignan, S., Stevens, P. E., O'Donoghue, D. J., Walker, M. D., & Hilton, S. R. (2005) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfi006 · Cited by 53
Cited by
Biomarkers in chronic kidney disease, from kidney function to kidney damage
Lopez-Giacoman, S. (2015) · World Journal of Nephrology · doi:10.5527/wjn.v4.i1.57 · Cited by 392
Discovery and prioritization of variants and genes for kidney function in >1.2 million individuals
Stanzick, K. J., Li, Y., Schlosser, P., Gorski, M., Wuttke, M., Thomas, L. F., Rasheed, H., Rowan, B. X., Graham, S. E., Vanderweff, B. R., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24491-0 · Cited by 302
Monitoring Renal Function and Limitations of Renal Function Tests
Prigent, A. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.09.003 · Cited by 170
Metadata
- Authors
- Traynor, J., Mactier, R., Geddes, C. C., & Fox, J. G.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2006-10-05
- Volume
- 333
- Issue
- 7571
- Pages
- 733-737
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2022379644
- Cited by
- 290
- References
- 23
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.