Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 451

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39 821 newborns

Open access
de-Wahl Granelli, A., Wennergren, M., Sandberg, K., Mellander, M., Bejlum, C., Inganas, L., Eriksson, M., Segerdahl, N., Agren, A., Ekman-Joelsson, B.-M., Sunnegardh, J., Verdicchio, M., Ostman-Smith, I.·2009·BMJ

Abstract

OBJECTIVE: To evaluate the use of pulse oximetry to screen for early detection of life threatening congenital heart disease. DESIGN: Prospective screening study with a new generation pulse oximeter before discharge from well baby nurseries in West Götaland. Cohort study comparing the detection rate of duct dependent circulation in West Götaland with that in other regions not using pulse oximetry screening. Deaths at home with undetected duct dependent circulation were included. SETTING: All 5 maternity units in West Götaland and the supraregional referral centre for neonatal cardiac surgery. PARTICIPANTS: 39,821 screened babies born between 1 July 2004 and 31 March 2007. Total duct dependent circulation cohorts: West Götaland n=60, other referring regions n=100. MAIN OUTCOME MEASURES: Sensitivity, specificity, positive and negative predictive values, and likelihood ratio for pulse oximetry screening and for neonatal physical examination alone. RESULTS: In West Götaland 29 babies in well baby nurseries had duct dependent circulation undetected before neonatal discharge examination. In 13 cases, pulse oximetry showed oxygen saturations <or=90%, and (in accordance with protocol) clinical staff were immediately told of the results. Of the remaining 16 cases, physical examination alone detected 10 (63%). Combining physical examination with pulse oximetry screening had a sensitivity of 24/29 (82.8% (95% CI 64.2% to 95.2%)) and detected 100% of the babies with duct dependent lung circulation. Five cases were missed (all with aortic arch obstruction). False positive rate with pulse oximetry was substantially lower than that with physical examination alone (69/39 821 (0.17%) v 729/38 413 (1.90%), P<0.0001), and 31/69 of the "false positive" cases with pulse oximetry had other pathology. Thus, referral of all cases with positive oximetry results for echocardiography resulted in only 2.3 echocardiograms with normal cardiac findings for every true positive case of duct dependent circulation. In the cohort study, the risk of leaving hospital with undiagnosed duct dependent circulation was 28/100 (28%) in other referring regions versus 5/60 (8%) in West Götaland (P=0.0025, relative risk 3.36 (95% CI 1.37 to 8.24)). In the other referring regions 11/25 (44%) of babies with transposition of the great arteries left hospital undiagnosed versus 0/18 in West Götaland (P=0.0010), and severe acidosis at diagnosis was more common (33/100 (33%) v 7/60 (12%), P=0.0025, relative risk 2.8 (1.3 to 6.0)). Excluding premature babies and Norwood surgery, babies discharged without diagnosis had higher mortality than those diagnosed in hospital (4/27 (18%) v 1/110 (0.9%), P=0.0054). No baby died from undiagnosed duct dependent circulation in West Götaland versus five babies from the other referring regions. CONCLUSION: Introducing pulse oximetry screening before discharge improved total detection rate of duct dependent circulation to 92%. Such screening seems cost neutral in the short term, but the probable prevention of neurological morbidity and reduced need for preoperative neonatal intensive care suggest that such screening will be cost effective long term.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.a3037

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 451

Metadata

Authors
de-Wahl Granelli, A., Wennergren, M., Sandberg, K., Mellander, M., Bejlum, C., Inganas, L., Eriksson, M., Segerdahl, N., Agren, A., Ekman-Joelsson, B.-M., Sunnegardh, J., Verdicchio, M., & Ostman-Smith, I.
Venue
BMJ
Publisher
BMJ
Published
2009-01-08
Volume
338
Issue
jan08 2
Pages
a3037-a3037
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2075587634
Cited by
451
References
21
FWCI
15.42
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39 821 newborns. https://app.cochat.ai/papers/10.1136/bmj.a3037
The paper
de-Wahl Granelli, A., Wennergren, M., Sandberg, K., Mellander, M., Bejlum, C., Inganas, L., Eriksson, M., Segerdahl, N., Agren, A., Ekman-Joelsson, B.-M., Sunnegardh, J., Verdicchio, M., & Ostman-Smith, I. (2009). Impact of pulse oximetry screening on the detection of duct dependent congenital heart disease: a Swedish prospective screening study in 39 821 newborns. BMJ. https://doi.org/10.1136/bmj.a3037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.