CoChat

Association of onset to balloon and door to balloon time with long term clinical outcome in patients with ST elevation acute myocardial infarction having primary percutaneous coronary intervention: observational study

Open access
Shiomi, H., Nakagawa, Y., Morimoto, T., Furukawa, Y., Nakano, A., Shirai, S., Taniguchi, R., Yamaji, K., Nagao, K., Suyama, T., Mitsuoka, H., Araki, M., Takashima, H., Mizoguchi, T., Eisawa, H., Sugiyama, S., Kimura, T., on behalf of the CREDO-Kyoto AMI investigators · 2012 · BMJ
Cited by 206

The DOI matches its Crossref record.

Abstract

OBJECTIVE: To evaluate the relation of symptom onset to balloon time and door to balloon time with long term clinical outcome in patients with ST segment elevation myocardial infarction (STEMI) having primary percutaneous coronary intervention. DESIGN: Observation of large cohort of patients with acute myocardial infarction. SETTING: 26 tertiary hospitals in Japan. PARTICIPANTS: 3391 patients with STEMI who had primary percutaneous coronary intervention within 24 hours of symptom onset. MAIN OUTCOME MEASURES: Composite of death and congestive heart failure, compared by onset to balloon time and door to balloon time. RESULTS: Compared with an onset to balloon time greater than 3 hours, a time of less than 3 hours was associated with a lower incidence of a composite of death and congestive heart failure (13.5% (123/964) v 19.2% (429/2427), P<0.001; relative risk reduction 29.7%). After adjustment for confounders, a short onset to balloon time was independently associated with a lower risk of the composite endpoint (adjusted hazard ratio 0.70, 95% confidence interval 0.56 to 0.88; P=0.002). However, no significant difference was found in the incidence of a composite of death and congestive heart failure between the two groups of patients with short (≤90 minutes) and long (>90 minutes) door to balloon time (16.7% (270/1671) v 18.4% (282/1720), P=0.54; relative risk reduction 9.2%). After adjustment for confounders, no significant difference was seen in the risk of the composite endpoint between the two groups of patients with short and long door to balloon time (adjusted hazard ratio: 0.98, 0.78 to 1.24: P=0.87). A door to balloon time of less than 90 minutes was associated with a lower incidence of a composite of death and congestive heart failure in patients who presented within 2 hours of symptom onset (11.9% (74/883) v 18.1% (147/655), P=0.01; relative risk reduction 34.3%) but not in patients who presented later (19.7% (196/788) v 18.7% (135/1065), P=0.44; -5.3%). Short door to balloon time was independently associated with a lower risk of a composite of death and congestive heart failure in patients with early presentation (adjusted hazard ratio 0.58, 0.38 to 0.87; P=0.009) but not in patients with delayed presentation (1.57, 1.12 to 2.18; P=0.008). A significant interaction was seen between door to balloon time and time to presentation (interaction P=0.01). CONCLUSIONS: Short onset to balloon time was associated with better 3 year clinical outcome in patients with STEMI having primary percutaneous coronary intervention, whereas the benefit of short door to balloon time was limited to patients who presented early. Efforts to minimise onset to balloon time, including reduction of patient related delay, should be recommended to improve clinical outcome in STEMI patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.e3257

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Shiomi, H., Nakagawa, Y., Morimoto, T., Furukawa, Y., Nakano, A., Shirai, S., Taniguchi, R., Yamaji, K., Nagao, K., Suyama, T., Mitsuoka, H., Araki, M., Takashima, H., Mizoguchi, T., Eisawa, H., Sugiyama, S., Kimura, T., & on behalf of the CREDO-Kyoto AMI investigators
Venue
BMJ
Publisher
BMJ
Published
2012-05-23
Volume
344
Issue
may23 1
Pages
e3257-e3257
ISSN
1756-1833 (ISSN-L)
OpenAlex
W2117403104
Cited by
206
References
0
FWCI
8.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.