CoChat

Effectiveness of routine third trimester ultrasonography to reduce adverse perinatal outcomes in low risk pregnancy (the IRIS study): nationwide, pragmatic, multicentre, stepped wedge cluster randomised trial

Open access
Henrichs, Jens, Verfaille, Viki, Jellema, Petra, Viester, Laura, Pajkrt, Eva, Wilschut, Janneke, van der Horst, Henriëtte E, Franx, Arie, de Jonge, Ank · 2019 · BMJ
Cited by 107

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objectives: To investigate the effectiveness of routine ultrasonography in the third trimester in reducing adverse perinatal outcomes in low risk pregnancies compared with usual care and the effect of this policy on maternal outcomes and obstetric interventions. Design: Pragmatic, multicentre, stepped wedge cluster randomised trial. Setting: 60 midwifery practices in the Netherlands. Participants: 13 046 women aged 16 years or older with a low risk singleton pregnancy. Interventions: 60 midwifery practices offered usual care (serial fundal height measurements with clinically indicated ultrasonography). After 3, 7, and 10 months, a third of the practices were randomised to the intervention strategy. As well as receiving usual care, women in the intervention strategy were offered two routine biometry scans at 28-30 and 34-36 weeks’ gestation. The same multidisciplinary protocol for detecting and managing fetal growth restriction was used in both strategies. Main outcome measures: The primary outcome measure was a composite of severe adverse perinatal outcomes: perinatal death, Apgar score <4, impaired consciousness, asphyxia, seizures, assisted ventilation, septicaemia, meningitis, bronchopulmonary dysplasia, intraventricular haemorrhage, periventricular leucomalacia, or necrotising enterocolitis. Secondary outcomes were two composite measures of severe maternal morbidity, and spontaneous labour and birth. Results: Between 1 February 2015 and 29 February 2016, 60 midwifery practices enrolled 13 520 women in mid-pregnancy (mean 22.8 (SD 2.4) weeks’ gestation). 13 046 women (intervention n=7067, usual care n=5979) with data based on the national Dutch perinatal registry or hospital records were included in the analyses. Small for gestational age at birth was significantly more often detected in the intervention group than in the usual care group (179 of 556 (32%) v 78 of 407 (19%), P<0.001). The incidence of severe adverse perinatal outcomes was 1.7% (n=118) for the intervention strategy and 1.8% (n=106) for usual care. After adjustment for confounders, the difference between the groups was not significant (odds ratio 0.88, 95% confidence interval 0.70 to 1.20). The intervention strategy showed a higher incidence of induction of labour (1.16, 1.04 to 1.30) and a lower incidence of augmentation of labour (0.78, 0.71 to 0.85). Maternal outcomes and other obstetric interventions did not differ between the strategies. Conclusion: In low risk pregnancies, routine ultrasonography in the third trimester along with clinically indicated ultrasonography was associated with higher antenatal detection of small for gestational age fetuses but not with a reduced incidence of severe adverse perinatal outcomes compared with usual care alone. The findings do not support routine ultrasonography in the third trimester for low risk pregnancies. Trial registration: Netherlands Trial Register NTR4367.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.l5517

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 107

Metadata

Authors
Henrichs, J., Verfaille, V., Jellema, P., Viester, L., Pajkrt, E., Wilschut, J., van der Horst, H. E., Franx, A., & de Jonge, A.
Venue
BMJ
Publisher
BMJ
Published
2019-10-15
Volume
367
Pages
l5517
ISSN
  • 1756-1833 (ISSN-L)
  • 0959-8138
OpenAlex
W2980659881
Cited by
107
References
4
FWCI
13.07
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.