CoChat

Non-invasive wearables for remote monitoring of HbA1c and glucose variability: proof of concept

Open access
Bent, Brinnae, Cho, Peter J, Wittmann, April, Thacker, Connie, Muppidi, Srikanth, Snyder, Michael, Crowley, Matthew J, Feinglos, Mark, Dunn, Jessilyn P · 2021 · BMJ Open Diabetes Research & Care
Cited by 40

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Introduction: Diabetes prevalence continues to grow and there remains a significant diagnostic gap in one-third of the US population that has pre-diabetes. Innovative, practical strategies to improve monitoring of glycemic health are desperately needed. In this proof-of-concept study, we explore the relationship between non-invasive wearables and glycemic metrics and demonstrate the feasibility of using non-invasive wearables to estimate glycemic metrics, including hemoglobin A1c (HbA1c) and glucose variability metrics. Research design and methods: We recorded over 25 000 measurements from a continuous glucose monitor (CGM) with simultaneous wrist-worn wearable (skin temperature, electrodermal activity, heart rate, and accelerometry sensors) data over 8–10 days in 16 participants with normal glycemic state and pre-diabetes (HbA1c 5.2–6.4). We used data from the wearable to develop machine learning models to predict HbA1c recorded on day 0 and glucose variability calculated from the CGM. We tested the accuracy of the HbA1c model on a retrospective, external validation cohort of 10 additional participants and compared results against CGM-based HbA1c estimation models. Results: A total of 250 days of data from 26 participants were collected. Out of the 27 models of glucose variability metrics that we developed using non-invasive wearables, 11 of the models achieved high accuracy (<10% mean average per cent error, MAPE). Our HbA1c estimation model using non-invasive wearables data achieved MAPE of 5.1% on an external validation cohort. The ranking of wearable sensor’s importance in estimating HbA1c was skin temperature (33%), electrodermal activity (28%), accelerometry (25%), and heart rate (14%). Conclusions: This study demonstrates the feasibility of using non-invasive wearables to estimate glucose variability metrics and HbA1c for glycemic monitoring and investigates the relationship between non-invasive wearables and the glycemic metrics of glucose variability and HbA1c. The methods used in this study can be used to inform future studies confirming the results of this proof-of-concept study.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmjdrc-2020-002027

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 40

Metadata

Authors
Bent, B., Cho, P. J., Wittmann, A., Thacker, C., Muppidi, S., Snyder, M., Crowley, M. J., Feinglos, M., & Dunn, J. P.
Venue
BMJ Open Diabetes Research & Care
Publisher
BMJ
Published
2021-06
Volume
9
Issue
1
Pages
e002027
ISSN
2052-4897 (ISSN-L)
OpenAlex
W3172358880
Cited by
40
References
17
FWCI
4.21
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-invasive wearables for remote monitoring of HbA1c and glucose variability: proof of concept. https://app.cochat.ai/papers/10.1136/bmjdrc-2020-002027
The paper
Bent, B., Cho, P. J., Wittmann, A., Thacker, C., Muppidi, S., Snyder, M., Crowley, M. J., Feinglos, M., & Dunn, J. P. (2021). Non-invasive wearables for remote monitoring of HbA1c and glucose variability: proof of concept. BMJ Open Diabetes Research & Care. https://doi.org/10.1136/bmjdrc-2020-002027

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.