Patterns in the recording of vital signs and early warning scores: compliance with a clinical escalation protocol
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: The recognition of patient deterioration depends largely on identifying abnormal vital signs, yet little is known about the daily pattern of vital signs measurement and charting. Methods: We compared the pattern of vital signs and VitalPAC Early Warning Score (ViEWS) data collected from admissions to all adult inpatient areas (except high care areas, such as critical care units) of a NHS district general hospital from 1 May 2010 to 30 April 2011, to the hospital's clinical escalation protocol. Main outcome measures were hourly and daily patterns of vital signs and ViEWS value documentation; numbers of vital signs in the periods 08:00–11:59 and 20:00–23:59 with subsequent vital signs recorded in the following 6 h; and time to next observation (TTNO) for vital signs recorded in the periods 08:00–11:59 and 20:00–23:59. Results: 950 043 vital sign datasets were recorded. The daily pattern of observation documentation was not uniform; there were large morning and evening peaks, and lower night-time documentation. The pattern was identical on all days. 23.84% of vital sign datasets with ViEWS ≥ 9 were measured at night compared with 10.12–19.97% for other ViEWS values. 47.42% of patients with ViEWS=7–8 and 31.22% of those with ViEWS ≥ 9 in the period 20:00–23:59 did not have vital signs recorded in the following 6 h. TTNO decreased with increasing ViEWS value, but less than expected by the monitoring protocol. Conclusions: There was only partial adherence to the vital signs monitoring protocol. Sicker patients appear more likely to have vital signs measured overnight, but even their observations were often not followed by timely repeat assessments. The observed pattern of monitoring may reflect the impact of competing clinical priorities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nangalia, V., Prytherch, D. R., & Smith, G. B. (2010) · Critical Care · doi:10.1186/cc9208 · Cited by 150
Self-citation
Cited by
Goodman, D., Ogrinc, G., Davies, L., Baker, G. R., Barnsteiner, J., Foster, T. C., Gali, K., Hilden, J., Horwitz, L., Kaplan, H. C., et al. (2016) · BMJ Quality & Safety · doi:10.1136/bmjqs-2015-004480 · Cited by 374
Internet of Health Things: Toward intelligent vital signs monitoring in hospital wards
da Costa, C. A., Pasluosta, C. F., Eskofier, B., da Silva, D. B., & da Rosa Righi, R. (2018) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2018.05.005 · Cited by 273
Strengths and limitations of early warning scores: A systematic review and narrative synthesis
Downey, C. L., Tahir, W., Randell, R., Brown, J. M., & Jayne, D. G. (2017) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2017.09.003 · Cited by 258
Adly, A. S., Adly, A. S., & Adly, M. S. (2020) · Journal of Medical Internet Research · doi:10.2196/19104 · Cited by 138
Sankey, C. B., McAvay, G., Siner, J. M., Barsky, C. L., & Chaudhry, S. I. (2016) · Journal of General Internal Medicine · doi:10.1007/s11606-016-3654-x · Cited by 60
Metadata
- Authors
- Hands, C., Reid, E., Meredith, P., Smith, G. B., Prytherch, D. R., Schmidt, P. E., & Featherstone, P. I.
- Venue
- BMJ Quality & Safety
- Publisher
- BMJ
- Published
- 2013-04-19
- Volume
- 22
- Issue
- 9
- Pages
- 719-726
- ISSN
- 1475-3898 (ISSN-L)
- 2044-5415
- 2044-5423
- OpenAlex
- W2136141962
- Cited by
- 151
- References
- 1
- FWCI
- 11.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Patterns in the recording of vital signs and early warning scores: compliance with a clinical escalation protocol. https://app.cochat.ai/papers/10.1136/bmjqs-2013-001954
- The paper
- Hands, C., Reid, E., Meredith, P., Smith, G. B., Prytherch, D. R., Schmidt, P. E., & Featherstone, P. I. (2013). Patterns in the recording of vital signs and early warning scores: compliance with a clinical escalation protocol. BMJ Quality & Safety. https://doi.org/10.1136/bmjqs-2013-001954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.