Thigh-worn accelerometry for measuring movement and posture across the 24-hour cycle: a scoping review and expert statement
Open accessThe DOI matches its Crossref record; 129 of the 130 references it cites were found in a registry or an index.
Abstract
Introduction: The Prospective Physical Activity Sitting and Sleep consortium (ProPASS) is an international collaboration platform committed to harmonise thigh-worn accelerometry data. The aim of this paper is to (1) outline observational thigh-worn accelerometry studies and (2) summarise key strategic directions arising from the inaugural ProPASS meeting. Methods: (1) We performed a systematic scoping review for observational studies of thigh-worn triaxial accelerometers in free-living adults (n≥100, 24 hours monitoring protocols). (2)Attendees of the inaugural ProPASS meeting were sent a survey focused on areas related to developing ProPASS: important terminology (Q1); accelerometry constructs (Q2); advantages and distinct contribution of the consortium (Q3); data pooling and harmonisation (Q4); data access and sharing (Q5 and Q6). Results: (1) Eighty eligible articles were identified (22 primary studies; n~17 685). The accelerometers used most often were the ActivPAL3 and ActiGraph GT3X. The most commonly collected health outcomes were cardiometabolic and musculoskeletal. (2) None of the survey questions elicited the predefined 60% agreement. Survey responses recommended that ProPASS: use the term physical behaviour or movement behaviour rather than ‘physical activity’ for the data we are collecting (Q1); make only minor changes to ProPASS’s accelerometry construct (Q2); prioritise developing standardised protocols/tools (Q4); facilitate flexible methods of data sharing and access (Q5 and Q6). Conclusions: Thigh-worn accelerometry is an emerging method of capturing movement and posture across the 24 hours cycle. In 2020, the literature is limited to 22 primary studies from high-income western countries. This work identified ProPASS’s strategic directions—indicating areas where ProPASS can most benefit the field of research: use of clear terminology, refinement of the measured construct, standardised protocols/tools and flexible data sharing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In contrast to questionnaires, wearable devices such as wrist24,25 or thigh26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA19.”
From Association of wearable device-measured vigorous intermittent lifestyle physical activity with mortality (2022) · cites this paper as [26]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation
Tricco, A. C., Lillie, E., Zarin, W., O'Brien, K. K., Colquhoun, H., Levac, D., Moher, D., Peters, M. D. J., Horsley, T., Weeks, L., et al. (2018) · Annals of Internal Medicine · doi:10.7326/m18-0850 · Cited by 43,565 · cited 1×
“Data extraction, undertaken by a single author (EIE and MLS), included details of: The data extracted is presented and summarised.”
MethodPreferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.06.005 · Cited by 19,575 · cited 1×
“In line with publications describing previous accelerometry consortia, 23 24 and the PRISMA Extension for Scoping Reviews.”
‘Small Changes' to Diet and Physical Activity Behaviors for Weight Management
Hills, A. P., Byrne, N. M., Lindstrom, R., & Hill, J. O. (2013) · Obesity Facts · doi:10.1159/000345030 · Cited by 9,493
Lee, I.-M., Shiroma, E. J., Lobelo, F., Puska, P., Blair, S. N., & Katzmarzyk, P. T. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61031-9 · Cited by 8,215
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“In 8–10 This location was initially chosen due to its simplicity (ease of setup and wear) and close proximity to a person’s centre of gravity (mini-mising the effect of extraneous movement).”
Fit Yourself and Take Your Lungs to Heart
Palange, P., & Bonini, M. (2013) · Respiration · doi:10.1159/000350831 · Cited by 2,779
Three-dimensional Epigenome Statistical Model: Genome-wide Chromatin Looping Prediction
Al Bkhetan, Z., & Plewczynski, D. (2018) · Scientific Reports · doi:10.1038/s41598-018-23276-8 · Cited by 1,662
Cook, N. R., Lee, I.-M., Gaziano, J. M., Gordon, D., Ridker, P. M., Manson, J. E., Hennekens, C. H., & Buring, J. E. (2005) · JAMA · doi:10.1001/jama.294.1.47 · Cited by 796
Research works printed but not linked: 8
- 10.1249/mss · doi:10.1249/mss
- 10.1186/s12966-020-01042-2/tables/2 · doi:10.1186/s12966-020-01042-2/tables/2
- 10.1186/s12889-019-6576-9 · DOI · Paper page
- 10.1186/s12877-019-1389-3 · DOI
- 10.1186/s12889-019-6576-9 · DOI · Paper page
- 10.1186/s12889-019-6576-9 · DOI · Paper page
- 10.1186/s12966-020-01042-2/tables/2 · doi:10.1186/s12966-020-01042-2/tables/2
- 10.1186/s12889-016-3110-1 · DOI · Paper page
Cited by
Stamatakis, E., Ahmadi, M. N., Gill, J. M. R., Thøgersen-Ntoumani, C., Gibala, M. J., Doherty, A., & Hamer, M. (2022) · Nature Medicine · doi:10.1038/s41591-022-02100-x · Cited by 336
“In contrast to questionnaires, wearable devices such as wrist 24,25 or thigh 26,27 accelerometers continuously record movement at a high resolution allowing them to capture fine-grain patterns of brief physical activity bouts, such as VILPA 19 .”
Self-citationUstad, A., Logacjov, A., Trollebø, S. Ø., Thingstad, P., Vereijken, B., Bach, K., & Skjæret-Maroni, N. (2023) · Sensors · doi:10.3390/s23052368 · Cited by 100
Bach, K., Kongsvold, A., Bårdstu, H. B., Bardal, E. M., Kjærnli, H. S., Herland, S., Logacjov, A., & Mork, P. J. (2021) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2021-0015 · Cited by 85
Self-citationPulsford, R. M., Brocklebank, L. A., Fenton, S. A. M., Bakker, E. A., Mielke, G. I., Tsai, L., Atkin, A. J., Harvey, D. L., Blodgett, J. M., Ahmadi, M. N., et al. (2023) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-022-01388-9 · Cited by 68
“However, findings are consistent with previous research reporting that simple ‘wrist-watch-like’ attachment of accelerometers is less burdensome for participants [12] and associated with higher wear compliance [16, 24].”
ResultSelf-citationTimm, I., Giurgiu, M., Ebner‐Priemer, U., & Reichert, M. (2024) · Sports Medicine · doi:10.1007/s40279-024-02016-1 · Cited by 57
“4.3), describes a recent scientific model [52] operationalizing highly complex human PB characterized by distinct features such as PB type (e.g., walking, standing, or sitting), intensity (e.g., LPA or MVPA), purpose (e.g., structured exercise or gardening), and social-environmental context (e.g.,…”
BackgroundMethodInfluentialGiurgiu, M., Timm, I., Becker, M. L., Schmidt, S., Wunsch, K., Nissen, R., Davidovski, D., Bussmann, J. B. J., Nigg, C. R., Reichert, M., et al. (2022) · JMIR mhealth and uhealth · doi:10.2196/36377 · Cited by 55
“We evaluated the characteristics and quality of free-living validation studies in which at least one dimension of the 24-hour physical behavior construct (ie, biological state, posture or activity type, and intensity [1,4]) was assessed using wearables and validated against a criterion measure.”
BackgroundMethodInfluentialHettiarachchi, P., Aili, K., Holtermann, A., Stamatakis, E., Svartengren, M., & Palm, P. (2021) · Sensors · doi:10.3390/s21030904 · Cited by 50
“, walking, cycling, stair climbing and running) and body postures [4] and are frequently used to measure postures, sedentary behaviour and body movements continuously 24/7 [5,6].”
BackgroundSelf-citationUse of activPAL to Measure Physical Activity in Community-Dwelling Older Adults: A Systematic Review
Blackwood, J., Suzuki, R., Webster, N. J., Karczewski, H., Ziccardi, T., & Shah, S. (2022) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2022.100190 · Cited by 47
“A scoping review of observational studies describing the use of thigh-worn accelerometers to measure PA in free-living adults reported that the most often used device was the activPAL3.(28) The activPAL accelerometer is a 43-mm long, 23.”
BackgroundMethodJohansson, P. J., Crowley, P., Axelsson, J., Franklin, K. A., Garde, A. H., Hettiarachchi, P., Holtermann, A., Kecklund, G., Lindberg, E., Ljunggren, M. E., et al. (2022) · Journal of Sleep Research · doi:10.1111/jsr.13725 · Cited by 47
“…deriving physical activity and sedentary behaviour from thigh-worn accelerometers, which have been evaluated against the ‘gold standard’ (Edwardson et al., 2016; Skotte et al., 2014; Stemland et al., 2015; Stevens et al., 2020; Migueles et al., 2017; Hettiarachchi et al., 2021; Lyden et al., 2016).”
BackgroundMethodSelf-citationGiurgiu, M., Kolb, S., Nigg, C., Burchartz, A., Timm, I., Becker, M. L., Rulf, E., Doster, A.-K., Koch, E. D., Bussmann, J. B. J., et al. (2022) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2021-001267 · Cited by 43
Giurgiu, M., von Haaren‐Mack, B., Fiedler, J., Woll, S., Burchartz, A., Kolb, S., Ketelhut, S., Kubica, C., Nigg, C., Timm, I., et al. (2024) · Journal of sport and health science/Journal of Sport and Health Science · doi:10.1016/j.jshs.2024.101006 · Cited by 45
“7 However, with advancements in artificial intelligence, it is increasingly possible to derive sleep and physical activity phenotypes from sensor data.”
Nigg, C., Petersen, E., & Macintyre, T. E. (2023) · Journal of Environmental Psychology · doi:10.1016/j.jenvp.2023.102009 · Cited by 40
Effect of physical activity and exercise on telomere length: systematic review with meta-analysis
Valente, C., Andrade, R., Alvarez, L., Rebelo‐Marques, A., Stamatakis, E., & Espregueira‐Mendes, J. (2021) · Journal of the American Geriatrics Society · doi:10.1111/jgs.17334 · Cited by 34
Self-citationŠuc, A., Einfalt, L., Šarabon, N., & Kastelic, K. (2024) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-024-01632-4 · Cited by 40
“To avoid usage of multiple accelerometers, it was proposed that the best compromise might be using the same accelerometer at the hip during wake time and at the wrist during bedtime [115], or to combine thigh-worn accelerometer with sleep time diary [116].”
MethodGiurgiu, M., Ebner‐Priemer, U., & Dumuid, D. (2021) · Psychology of sport and exercise · doi:10.1016/j.psychsport.2021.102102 · Cited by 31
Giurgiu, M., Ketelhut, S., Kubica, C., Nissen, R., Doster, A.-K., Thron, M., Timm, I., Giurgiu, V., Nigg, C. R., Wöll, A., et al. (2023) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-023-01473-7 · Cited by 34
“, biological state, posture/activity type, or intensity [16], see Additional file 3).”
BackgroundComparing national device-based physical activity surveillance systems: a systematic review
de Wolf, I., Elevelt, A., van Nassau, F., Toepoel, V., de Hollander, E., Kompier, M. E., Luiten, A., Schouten, B., Wendel‐Vos, W., & van der Ploeg, H. P. (2024) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-024-01612-8 · Cited by 30
“Thigh-worn devices might be more suitable to wear 24 h a day as they do not need to change position and lower participant burden [88].”
BackgroundMontoye, A. H. K., Vondrasek, J. D., Neph, S. E., Basu, N., Paul, L., Bachmair, E., Stefanov, K., & Gray, S. R. (2022) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2021-0053 · Cited by 24
Crowley, P., Ikeda, E., Islam, S. M. S., Kildedal, R., Jacobsen, S. S., Larsen, J. R., Johansson, P. J., Hettiarachchi, P., Aadahl, M., Mork, P. J., et al. (2022) · JMIR Research Protocols · doi:10.2196/35697 · Cited by 24
Self-citationBird, M., Datta, G. D., Chinerman, D., Kakinami, L., Mathieu, M.-E., Henderson, M., & Barnett, T. A. (2022) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-022-01256-6 · Cited by 20
“Intensity zones (sleep, SP, LPA, MVPA) represent only one dimension of 24-hour movement behaviour [47].”
BackgroundBerger, M., Bertrand, A. M., Robert, T., & Chèze, L. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1236143 · Cited by 20
Campos-Garzón, P., Saucedo‐Araujo, R. G., Sevil‐Serrano, J., Migueles, J. H., Barranco-Ruíz, Y., & Chillón, P. (2023) · Transport Reviews · doi:10.1080/01441647.2023.2175276 · Cited by 17
“However, this placement also has many disadvantages, such as interference with clothing or the difficulty in quantifying PA in different postures and physical behaviours (e.g. sitting, climbing, etc.) (Ellis et al., 2016; Stevens et al., 2020).”
BackgroundInfluentialHuisman, H. C. V. D. , Bijnens, W., Senden, R. H. J., Essers, J. M. N. H., Meijer, K., Aarts, J., & Lenssen, A. F. (2021) · Sensors · doi:10.3390/s21051652 · Cited by 16
Physical Activity Epidemiology
Weber, A., Schmid, D., & Leitzmann, M. F. (2023) · Springer eBooks · doi:10.1007/978-1-4614-6625-3_67-1 · Cited by 16
Ng, J. Y. Y., Zhang, J. H., Hui, S. S., Jiang, G., Yau, F., Cheng, J. S.-C., & Ha, A. S. C. (2024) · PLoS ONE · doi:10.1371/journal.pone.0299295 · Cited by 15
“For example, the thigh [25], ankle [26], and ears [27] are all possible placement sites that could be incorporated in research in the future.”
BackgroundLendt, C., Braun, T., Biallas, B., Froböse, I., & Johansson, P. J. (2024) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-024-01627-1 · Cited by 15
“These behaviours are characterized by variables such as intensity, duration, and type, and are known to influence various health outcomes [1–3].”
BackgroundCross-sectional survey on researchers’ experience in using accelerometers in health-related studies
Albrecht, B. M., Flaßkamp, F. T., Koster, A., Eskofier, B. M., & Bammann, K. (2022) · BMJ Open Sport & Exercise Medicine · doi:10.1136/bmjsem-2021-001286 · Cited by 14
Self-citationGiurgiu, M., Nigg, C., Fiedler, J., Timm, I., Rulf, E., Bussmann, J. B. J., Nigg, C. R., Wöll, A., & Ebner‐Priemer, U. (2022) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2022-0014 · Cited by 13
Telford, D. M., Meiring, R. M., & Gusso, S. (2024) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2024.10.002 · Cited by 14
Gába, A., Hartwig, T. B., Jašková, P., Sanders, T., Dygrýn, J., Vencálek, O., Antczak, D., Conigrave, J. H., Parker, P. D., Cruz, B. D. P., et al. (2024) · Sports Medicine · doi:10.1007/s40279-024-02148-4 · Cited by 13
“Given the multi-dimensional nature of the 24-h movement behavior construct [56], future research should also incorporate additional dimensions such as posture-and domain-specific behaviors, in addition to intensity-specific behaviors.”
Wöll, A., Klos, L., Worth, A., Hanssen‐Doose, A., Hinz, T., Voelkle, M. C., Burchartz, A., & Niessner, C. (2025) · BMJ Open · doi:10.1136/bmjopen-2024-094895 · Cited by 13
Blodgett, J. M., Bann, D., CHASTIN, S. F. M., Ahmadi, M. N., Stamatakis, E., Cooper, R., & Hamer, M. (2024) · Journal of Epidemiology & Community Health · doi:10.1136/jech-2023-221726 · Cited by 11
“23 Finally, the separation of weekend and weekday data enables an improved understanding of potential contextual factors and aids in improving implementation frameworks needed for targeted PA and SB interventions.”
BackgroundSelf-citationJanda, D., Gába, A., Hron, K., Arundell, L., & Ayala, A. M. C. (2024) · BMC Public Health · doi:10.1186/s12889-024-19075-8 · Cited by 12
“Additionally, this study did not account for the multidimensional nature of the 24-hour MB construct [68], limiting our ability to identify specific aspects of 24-hour MB, such as posture-or domain-specific behaviours (e.g. screen time), that may influence adiposity.”
BackgroundLendt, C., Hettiarachchi, P., Johansson, P. J., Duncan, S., Rasmussen, C. L., Narayanan, A., & Stewart, T. I. (2024) · Journal of Physical Activity and Health · doi:10.1123/jpah.2024-0259 · Cited by 11
Giurgiu, M., & Ebner‐Priemer, U. (2025) · Journal of Activity Sedentary and Sleep Behaviors · doi:10.1186/s44167-025-00077-9 · Cited by 10
Ferrari, G., Herrera‐Cuenca, M., Zimberg, I. Z., Guajardo, V., Gómez, G., Quesada, D., Rigotti, A., Cortés, L. Y., García, M. C. Y., Pareja, R. G., et al. (2021) · Assessment · doi:10.1177/10731911211017637 · Cited by 10
Jadczak, A. D., Verma, M., Headland, M., Tucker, G., & Visvanathan, R. (2023) · The Journal of Frailty & Aging · doi:10.14283/jfa.2023.17 · Cited by 11
“The ActivPal accelerometer is a thigh-worn device allowing for objective measure of physical activity in older adults (32, 33).”
Bachman, S. L., Gomes, E. L., Aryal, S., Cella, D. F., Clay, I., Lyden, K. A., & Leach, H. J. (2024) · JMIR Cancer · doi:10.2196/53180 · Cited by 9
“These devices can furthermore capture many domains of physical behavior, including aspects of gait, mobility, posture, physical activity, and sedentary behavior [31-33].”
BackgroundMehta, S., Allen, L. H., Bailey, R. L., Boushey, C. J., Duggan, C., Crouter, S. E., Engle‐Stone, R., Fahim, S. M., Gibbs, K., Hernández, E., et al. (2025) · Journal of Nutrition · doi:10.1016/j.tjnut.2025.10.030 · Cited by 9
The performance of a machine learning model in predicting accelerometer-derived walking speed
Logacjov, A., Ludvigsen, T. P., Bach, K., Kongsvold, A., Flaaten, M., Nilsen, T. I. L., & Mork, P. J. (2025) · Heliyon · doi:10.1016/j.heliyon.2025.e42185 · Cited by 8
Self-citationClevenger, K. A., & Montoye, A. H. K. (2023) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0025 · Cited by 9
Wei, L., Ahmadi, M. N., Chan, H., CHASTIN, S. F. M., Hamer, M., Mishra, G. D., & Stamatakis, E. (2023) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.14363 · Cited by 7
Self-citationJanda, D., Gába, A., Vencálek, O., Fairclough, S. J., Dygrýn, J., Jakubec, L., & Rubín, L. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285952 · Cited by 7
“Such an approach helps to explain only part of the picture as the 24-h movement behaviours construct is multidimensional in its nature [11].”
BackgroundCrowley, P., Kildedal, R., Vindelev, S. O., Jacobsen, S. S., Larsen, J. R., Johansson, P. J., Aadahl, M., Straker, L. M., Stamatakis, E., Holtermann, A., et al. (2023) · JMIR Formative Research · doi:10.2196/48209 · Cited by 7
“The emergence of evidence highlighting the importance of multiple dimensions of physical behaviors [1,2] has placed new demands on the methods used to gather data [3,4].”
MethodSelf-citationNigg, C., Petersen, E., & Macintyre, T. E. (2021) · PsyArXiv (OSF Preprints) · doi:10.31234/osf.io/a9unf · Cited by 9
Comparing Physical Activity Metrics From Different Placements of Thigh-Worn Accelerometers
Franzese, F., Hettiarachchi, P., Holtermann, A., Ahmadi, M. N., & Johansson, P. J. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0043 · Cited by 8
Self-citationHayes, G., Buck, C., Cardon, G., Cimler, R., Elavsky, S., Fezeu, L., Harrington, J. M., Kühnová, J., Oppert, J., Sigcha, L., et al. (2025) · JMIR Research Protocols · doi:10.2196/70186 · Cited by 7
“The activPAL device was selected due to its unobtrusive and strategic placement on the body, enabling reliable continuous monitoring over 24-hour periods [44].”
Pesola, A. J., Esmaeilzadeh, S., Hakala, P., Kallio, N., Berg, P., Havu, M., & Rinne, T. E. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1113687 · Cited by 6
Lendt, C., Hansen, N., Froböse, I., & Stewart, T. I. (2024) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-024-01646-y · Cited by 7
Smits, E. J., Salomoni, S. E., Costa, N., Rodríguez‐Romero, B., & Hodges, P. W. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac482f · Cited by 6
Rantalainen, T., Koivunen, K., Portegijs, E., Rantanen, T., Palmberg, L., Karavirta, L., & CHASTIN, S. F. M. (2022) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002883 · Cited by 9
“Posture assessments may be particularly informative in daily activity behavior containing a large volume of stationary behavior where the distinction between sitting and standing may be of interest (19).”
BackgroundSelf-citationRasmussen, C. L., Hendry, D., Thomas, G., Beynon, A. M., Stearne, S., Zabatiero, J. G., Davey, P. C., Larsen, J. R., Rohl, A. L., Straker, L. M., et al. (2024) · Sensors · doi:10.3390/s24206705 · Cited by 5
“%) among adults [16–18].”
Self-citationKastelic, K., & Šarabon, N. (2023) · Kinesiology · doi:10.26582/k.55.2.12 · Cited by 5
“In this regard, we have seen greater progress for the device-based methods (Migueles, et al., 2017; Pulakka, et al., 2018; Stevens, et al., 2020) than for self-reported questionnaires (Rodrigues, et al., 2022a; Rodrigues, et al., 2022b).”
Monitoring postures and motions of hospitalized patients using sensor technology: a scoping review
Becker, M. L., Hurkmans, H. L. P., Verhaar, J. A. N., & Bussmann, J. B. J. (2024) · Annals of Medicine · doi:10.1080/07853890.2024.2399963 · Cited by 4
“A partial solution for this variability in analysis, is the collection of raw data, to unify outcomes using identical data processing methods [11,12,81,82].”
MethodGallagher, J. B., Boonstra, D. E., Borrowman, J. D., Unke, M., Jones, M. A., Kline, C. E., Gibbs, B. B., & Whitaker, K. M. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0007 · Cited by 4
Thomas, J. J. C., Daley, A., Esliger, D., Kettle, V. E., Coombe, A., Stamatakis, E., & Sanders, J. P. (2023) · Journal of Medical Internet Research · doi:10.2196/45599 · Cited by 3
“Although other reviews have aimed to identify data sets that have measured physical activity using an accelerometer [19,141], to our knowledge, this is the first study to create an interactive web-based catalog that can inform future harmonization and data pooling processes.”
Self-citationGiurgiu, M., Benedyk, A., Reichert, M., Berhe, O., Braun, U., Ebner‐Priemer, U., Tost, H., & Meyer‐Lindenberg, A. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.12310 · Cited by 4
Beauchamp, M., Kirkwood, R. N., Cooper, C., McIlroy, W. E., Ooteghem, K. V., Beyer, K. B., Richardson, J. A., Kuspinar, A., McNicholas, P. D., Newbold, K. B., et al. (2025) · BMJ Open · doi:10.1136/bmjopen-2025-105223 · Cited by 3
“27 41–44 Both devices have built-in triaxial accelerometers for recording high-resolution raw acceleration data and long-lasting batteries that eliminate the need for recharging during the data collection period.”
Ahrensberg, H., Christensen, A. I., Andersen, S., & Petersen, C. B. (2025) · Frontiers in Sleep · doi:10.3389/frsle.2025.1661250 · Cited by 3
Ludvigsen, T. P., Hørlück, S. A. S., Larsen, J. R., Lund, C. B., Hettiarachchi, P., Brandt, M., & Gupta, N. (2025) · Scientific Reports · doi:10.1038/s41598-025-26373-7 · Cited by 3
Self-citationStamatakis, E., Koemel, N. A., Milton, K. E., Keadle, S. K., Florindo, A. A., Hamer, M., Hallal, P. C., & Ahmadi, M. N. (2026) · Journal of Physical Activity and Health · doi:10.1123/jpah.2026-0466 · Cited by 4
Self-citationArumugam, A., Ghannami, Z., Mahallati, M., Al-Shams, H., Ahmed, S., Khaled, H., Hussein, M., Alkalih, H. Y., Montoye, A. H. K., Clevenger, K. A., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0324555 · Cited by 3
“Thus, comparing the accuracy and reliability of Fibion across different wear locations on the (ipsilateral and contralateral) thigh will help researchers determine the optimal location for wearability, and comparability with studies that may use various wear locations [16].”
Validity of the German Version of Daily Activity Behaviours Questionnaire Among Older Adults
Kastelic, K., Löfler, S., Matko, Š., & Šarabon, N. (2023) · Journal of Aging and Physical Activity · doi:10.1123/japa.2022-0417 · Cited by 3
Lindeman, K., Koivunen, K., Rantalainen, T., Rantakokko, M., Portegijs, E., Rantanen, T., & Karavirta, L. (2024) · Journal of Aging and Health · doi:10.1177/08982643241282918 · Cited by 3
“While accelerometers provide a method to continuously measure PA in free-living conditions, there is an ongoing debate as to whether absolute or relative (i.e., individualized) thresholds should be used when quantifying daily minutes of PA (Pedi ˇ si´c & Bauman, 2015; Stevens et al., 2020).”
Seol, J., So, R., Murai, F., & Matsuo, T. (2024) · BMC Public Health · doi:10.1186/s12889-023-17580-w · Cited by 2
“Further studies should focus on accelerometers worn in other locations (e.g., activPAL), which measure 24-h rest–activity rhythms [22, 23].”
BackgroundGracey-McMinn, L., Loudon, D. W., Chadwell, A., Curtin, S., Ostler, C., & Granat, M. H. (2025) · Sensors · doi:10.3390/s25164979 · Cited by 3
“Thigh-worn accelerometers are considered the “gold-standard” method for capturing movement data across a 24-h cycle [29].”
Self-citationHerranen, P., Palviainen, T., Nygaard, M., Karlsson, I., Thalamuthu, A., Mather, K. A., Reynolds, C. A., Panizzon, M. S., Rantanen, T., Finkel, D., et al. (2026) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000004019 · Cited by 2
“Although device-based measures such as accelerometers could provide more precise estimates of overall activity, their use in large population studies has only recently become feasible (60).”
Sigcha, L., Swenne, A., Hayes, G., Kühnová, J., Cimler, R., Elavsky, S., Větrovský, T., Fezeu, L., Bouchan, J., Oppert, J., et al. (2026) · JMIR mhealth and uhealth · doi:10.2196/94302 · Cited by 2
“In this context, PB refers to posture-and movement-based activity types that describe how time is accumulated across the day, including sedentary postures (eg, sitting or lying), upright postures (eg, standing), and movement behaviors (eg, walking, running, or cycling) [4].”
Stamatakis, E., Clark, B., Ahmadi, M. N., Blodgett, J. M., Granat, M. H., Donnelly, A., Atkin, A. J., Tsai, L., Mielke, G. I., Pulsford, R. M., et al. (2022) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2022-0027 · Cited by 2
“As of early 2018 (Stevens et al., 2020), ProPASS ’ objectives included the development of methods for processing, harmonizing, and pooling data from existing studies: the development of methods for collecting data for future studies (prospective harmonization) and building a vibrant early and…”
MethodSelf-citationMontoye, A. H. K., LaMunion, S. R., Brønd, J. C., & Clevenger, K. A. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2023-0057 · Cited by 2
“Yet, since 2010, accelerometers have been increasingly worn continuously on the wrist (Belcher et al., 2021; Doherty et al., 2017) or thigh (Stevens et al., 2020), enabling measurement of the full 24-hr period for seven days a week or longer.”
Esmaeilzadeh, S., Hakala, P., Berg, P., Salmon, J., Rinne, T. E., & Pesola, A. J. (2024) · Journal of Activity Sedentary and Sleep Behaviors · doi:10.1186/s44167-024-00053-9 · Cited by 2
“Triaxial thigh-worn accelerometry has been suggested to more accurately capture posture (e.g., standing, sitting), activity type (e.g., cycling, running, walking), and activity intensity compared to wrist and hip placements over a 24-hour cycle [18–21].”
BackgroundMarchiori, M., Heidler, J., Segantin, G., Eckmann, H. R., Chinapaw, M. J. M., Kjærgaard, M., & Schipperijn, J. (2025) · Journal of Activity Sedentary and Sleep Behaviors · doi:10.1186/s44167-025-00088-6 · Cited by 1
Sverdrup, K., Ustad, A., Tangen, G. G., Kongsvold, A., Vereijken, B., Strand, B. H., Selbæk, G., Ernstsen, L., & Mork, P. J. (2026) · Scientific Reports · doi:10.1038/s41598-026-36355-y · Cited by 1
“All analyses were performed using Stata 18.”
Self-citationWoll, S., Müther, J., Birkenmaier, D., Biri, G. I., Ebner‐Priemer, U., & Giurgiu, M. (2026) · Sensors · doi:10.3390/s26123688 · Cited by 1
“For instance, the wrist is commonly used for sleep applications [31], while the thigh location is preferred for accurately differentiating between standing and sitting/lying postures [13].”
de Lavor, J. M., Pina, A. K. A., de Brito, C. A., de Almeida, W. B., Brusaca, L. A., Schmit, E. F. D., Oliveira, A. B., da Silva, A. A. M., Magalhães, P., & Locks, F. (2024) · Applied Sciences · doi:10.3390/app14219637 · Cited by 1
Passfield, G., Mackay, L. M., Crofts, C. A. P., & Schofield, G. (2024) · medRxiv · doi:10.1101/2024.11.10.24317079 · Cited by 1
Factors influencing physical activity behaviour of hospitalised patients
Huisman, H. C. V. D. (2022) · Research Publications (Maastricht University) · doi:10.26481/dis.20221216hh · Cited by 1
Sayyah, M., Clemes, S. A., Maylor, B. D., Edwardson, C. L., Sherry, A. P., Ruettger, K. B., Chen, Y., Varela-Mato, V., Guest, A. J., King, J. A., et al. (2024) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0027
Said, M., Tawfick, W. A., Edwardson, C. L., Sultan, S., Alawy, M., & Jones, J. L. (2025) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2024.12.065
Steeves, J. A., Basu, N., Paul, L., Bachmair, E. M., Stefanov, K., Gray, S. R., Vondrasek, J. D., Neph, S. E., & Montoye, A. H. K. (2025) · Journal for the Measurement of Physical Behaviour · doi:10.1123/jmpb.2024-0047
Weber, B., Hermanns-Truxius, I., Wechsler, K., & Ellegast, R. P. (2025) · Springer series in design and innovation · doi:10.1007/978-981-96-8904-0_3
Schneider, S., Ebner‐Priemer, U., & Giurgiu, M. (2025) · European Journal of Sport Science · doi:10.1002/ejsc.70037
“According to Path C, switch cost was a significant predictor of sleep duration measured by Move, indicating that higher switch costs were associated with longer habitual sleep durations.”
Gait Analysis for Thigh-Worn Accelerometry A Data Processing Pipeline using Data-Driven ApproachesPreprint
Lendt, C., Grimmer, M., Froböse, I., & Stewart, T. I. (2025) · medRxiv · doi:10.1101/2025.11.18.25339671
Giurgiu, M., Hysenllari, E., Ottenbacher, J., Ebner‐Priemer, U., & Timm, I. (2025) · Translational Exercise Biomedicine · doi:10.1515/teb-2025-0027 · Cited by 1
Pulsford, R. M., Brocklebank, L. A., Fenton, S. A. M., Bakker, E., Mielke, G. I., Tsai, L.-T., Atkin, A. J., Harvey, D. L., Blodgett, J. M., Ahmadi, M., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22622464
Self-citationGiurgiu, M., Ketelhut, S., Kubica, C., Nissen, R., Doster, A.-K., Thron, M., Timm, I., Giurgiu, V., Nigg, C. R., Wöll, A., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26595635
Šuc, A., Einfalt, L., Šarabon, N., & Kastelic, K. (2024) · Figshare · doi:10.6084/m9.figshare.26757076
Giurgiu, M., Ketelhut, S., Kubica, C., Nissen, R., Doster, A.-K., Thron, M., Timm, I., Giurgiu, V., Nigg, C. R., Wöll, A., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26595632
de Wolf, I., Elevelt, A., van Nassau, F., Toepoel, V., de Hollander, E., Kompier, M. E., Luiten, A., Schouten, B., Wendel-Vos, G., & Ploeg, H. P. V. D. (2024) · Figshare · doi:10.6084/m9.figshare.26170597
Pulsford, R. M., Brocklebank, L. A., Fenton, S. A. M., Bakker, E., Mielke, G. I., Tsai, L.-T., Atkin, A. J., Harvey, D. L., Blodgett, J. M., Ahmadi, M., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22622467
Self-citationŠuc, A., Einfalt, L., Šarabon, N., & Kastelic, K. (2024) · Figshare · doi:10.6084/m9.figshare.26757079
Lendt, C., Braun, T., Biallas, B., Froböse, I., & Johansson, P. J. (2024) · Figshare · doi:10.6084/m9.figshare.26322754
Bird, M., Datta, G. D., Chinerman, D., Kakinami, L., Mathieu, M.-E., Henderson, M., & Barnett, T. A. (2022) · Figshare · doi:10.6084/m9.figshare.19793495
Seol, J., So, R., Murai, F., & Matsuo, T. (2024) · Figshare · doi:10.6084/m9.figshare.26659018
Giurgiu, M., Ketelhut, S., Kubica, C., Nissen, R., Doster, A.-K., Thron, M., Timm, I., Giurgiu, V., Nigg, C. R., Wöll, A., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26595629
Giurgiu, M., Ketelhut, S., Kubica, C., Nissen, R., Doster, A.-K., Thron, M., Timm, I., Giurgiu, V., Nigg, C. R., Wöll, A., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26595623
Pulsford, R. M., Brocklebank, L. A., Fenton, S. A. M., Bakker, E., Mielke, G. I., Tsai, L.-T., Atkin, A. J., Harvey, D. L., Blodgett, J. M., Ahmadi, M., et al. (2023) · Figshare · doi:10.6084/m9.figshare.22622458
Self-citationGiurgiu, M., Ketelhut, S., Kubica, C., Nissen, R., Doster, A.-K., Thron, M., Timm, I., Giurgiu, V., Nigg, C. R., Wöll, A., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26595617
Lendt, C., Hansen, N., Froböse, I., & Stewart, T. (2024) · Figshare · doi:10.6084/m9.figshare.26982080
Metadata
- Authors
- Stevens, M. L., Gupta, N., Inan Eroglu, E., Crowley, P. J., Eroglu, B., Bauman, A., Granat, M., Straker, L., Palm, P., Stenholm, S., Aadahl, M., Mork, P., Chastin, S., Rangul, V., Hamer, M., Koster, A., Holtermann, A., & Stamatakis, E.
- Affiliations
- National Research Centre for the Working Environment (DK)
- Boden Collaboration for Obesity, Nutrition, Exercise & Eating Disorders, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia
- The University of Sydney (AU)
- University of Salford (GB)
- Curtin University (AU)
- Uppsala University (SE)
- University of Turku (FI)
- Frederiksberg Hospital (DK)
- Norwegian University of Science and Technology (NO)
- Glasgow Caledonian University (GB)
- University College London (GB)
- Maastricht University (NL)
- Corresponding author
- Stevens, Matthew L
- ORCID
- Venue
- BMJ Open Sport & Exercise Medicine
- Publisher
- BMJ
- Published
- 2020-12
- Volume
- 6
- Issue
- 1
- Pages
- e000874
- ISSN
- 2055-7647 (ISSN-L)
- PMC
- PMC7768971
- OpenAlex
- W3114527818
- Cited by
- 110
- References
- 130
- Citations by year
- 2026: 8 · 2025: 18 · 2024: 41 · 2023: 20 · 2022: 15 · 2021: 8
- FWCI
- 1.37
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMJ Open Sport & Exercise Medicine (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, cc-by-nc)
- ResearchOnline (Glasgow Caledonian University) (acceptedVersion, cc-by-nc)
- University of Salford Institutional Repository (University of Salford) (submittedVersion, cc-by)
- UTUPub (University of Turku) (submittedVersion, other-oa)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion, cc-by-nc)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion, cc-by-nc)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- NORA - Norwegian Open Research Archives (submittedVersion, cc-by-nc)
- Research Publications (Maastricht University) (submittedVersion, cc-by-nc)
- Funders
- University of Sydney
- PAL Technologies
- British Heart Foundation (SP/F/20/150002)
- Worldwide Universities Network–Research Development Fund
- Loughborough University
- National Health and Medical Research Council
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- triaxial accelerometer, physical activity measurement, movement behavior, posture, data harmonization, data sharing, terminology, standardized protocols, ActiGraph GT3X+
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.