CoChat

Sensitive troponin assay predicts outcome in syncope

Reed, Matthew J, Mills, Nicholas L, Weir, Christopher J · 2012 · Emergency Medicine Journal

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Aims: To assess whether plasma troponin concentration measured by a sensitive assay can predict 1-month and 1-year serious outcome, or all-cause death in patients presenting with syncope to the emergency department (ED). Methods: Prospective cohort study of admitted adult patients presenting to the ED after an episode of syncope who had plasma troponin measured 12 h after syncope using the ARCHITECT STAT sensitive troponin I assay (Abbott Diagnostics). Primary endpoints were the composite endpoint of serious outcome or all-cause death at 1 month and 1 year. Results: Between 1 March 2007 and 22 July 2008, 338 of 528 patients admitted from the ED with syncope had plasma troponin concentrations determined. Troponin concentrations were above the limit of detection in 261 (77%) patients. Patients numbering 120 (36%) had a troponin concentration ≥0.03 ng/ml (99th percentile of normal reference population), and 66 (20%) had concentrations ≥0.05 ng/ml (local diagnostic threshold for myocardial infarction). The proportion of patients with a composite serious outcome increased across patients stratified into quintiles based on peak troponin concentration at 1 month (0%, 9%, 13%, 26%, 70%) and at 1 year (10%, 22%, 26%, 52%, 85%). Conclusions: The majority of patients admitted from the ED with syncope have detectable plasma troponin concentrations. Peak troponin concentration was associated with increasing risk of serious outcome and death, and this risk increases with higher troponin concentrations. Troponin may have a future role in the risk stratification of patients with syncope.

Overview

Integrity signals

Registry

Crossref · 10.1136/emermed-2012-201332

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 6 references

Cited by

See all 33

Metadata

Authors
Reed, M. J., Mills, N. L., & Weir, C. J.
Affiliations
  • Edinburgh Royal Infirmary (GB)
  • University of Edinburgh (GB)
Corresponding author
Reed, Matthew J
Venue
Emergency Medicine Journal
Publisher
BMJ
Published
2012-09-08
Volume
29
Issue
12
Pages
1001-1003
ISSN
  • 1351-0622 (ISSN-L)
  • 1472-0205
  • 1472-0213
OpenAlex
W2118982917
Cited by
33
References
6
Citations by year
2025: 1 · 2020: 4 · 2019: 1 · 2018: 7 · 2017: 7 · 2015: 4 · 2014: 4 · 2013: 3 · 2012: 2
FWCI
2.68
Type
journal article
Language
en
Open access
closed
Locations
  • Emergency Medicine Journal (publishedVersion)
  • PubMed (publishedVersion)
Funders
British Heart Foundation (FS/10/024/28266)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Takotsubo Cardiomyopathy and Associated Phenomena
Keywords
syncope, troponin I, all-cause mortality, risk stratification, myocardial infarction, emergency department patients, cardiac biomarkers
MeSH terms
Adult, Aged, Emergency Medicine, Emergency Service, Hospital, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Scotland, Sensitivity and Specificity, Syncope, Troponin, Biomarkers, Outcome Assessment, Health Care, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitive troponin assay predicts outcome in syncope. https://app.cochat.ai/papers/10.1136/emermed-2012-201332
The paper
Reed, M. J., Mills, N. L., & Weir, C. J. (2012). Sensitive troponin assay predicts outcome in syncope. Emergency Medicine Journal. https://doi.org/10.1136/emermed-2012-201332

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.