The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Implementation of a Sensitive Troponin I Assay and Risk of Recurrent Myocardial Infarction and Death in Patients With Suspected Acute Coronary Syndrome
Abstract
CONTEXT: Although troponin assays have become increasingly more sensitive, it is unclear whether further reductions in the threshold of detection for plasma troponin concentrations will improve clinical outcomes in patients with suspected acute coronary syndrome (ACS). OBJECTIVE: To determine whether lowering the diagnostic threshold for myocardial infarction (MI) with a sensitive troponin assay could improve clinical outcomes. DESIGN, SETTING, AND PATIENTS: All consecutive patients admitted with suspected ACS to the Royal Infirmary of Edinburgh, Edinburgh, Scotland, before (n = 1038; February 1-July 31, 2008, during the validation phase) and after (n = 1054; February 1-July 31, 2009, during the implementation phase) lowering the threshold of detection for myocardial necrosis from 0.20 to 0.05 ng/mL with a sensitive troponin I assay were stratified into 3 groups (<0.05 ng/mL, 0.05-0.19 ng/mL, and ≥0.20 ng/mL). During the validation phase, only concentrations above the original diagnostic threshold of 0.20 ng/mL were reported to clinicians. MAIN OUTCOME MEASURE: Event-free survival (recurrent MI and death) at 1 year in patients grouped by plasma troponin concentrations. RESULTS: Plasma troponin concentrations were less than 0.05 ng/mL in 1340 patients (64%), 0.05 to 0.19 ng/mL in 170 patients (8%), and 0.20 ng/mL or more in 582 patients (28%). During the validation phase, 39% of patients with plasma troponin concentrations of 0.05 to 0.19 ng/mL were dead or had recurrent MI at 1 year compared with 7% and 24% of those patients with troponin concentrations of less than 0.05 ng/mL (P < .001) or 0.20 ng/mL or more (P = .007), respectively. During the implementation phase, lowering the diagnostic threshold to 0.05 ng/mL was associated with a lower risk of death and recurrent MI (from 39% to 21%) in patients with troponin concentrations of 0.05 to 0.19 ng/mL (odds ratio, 0.42; 95% confidence interval, 0.24-0.84; P = .01). CONCLUSIONS: In patients with suspected ACS, implementation of a sensitive troponin assay increased the diagnosis of MI and identified patients at high risk of recurrent MI and death. Lowering the diagnostic threshold of plasma troponin was associated with major reductions in morbidity and mortality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Cited by
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., & White, H. D. (2012) · Circulation · doi:10.1161/cir.0b013e31826e1058 · Cited by 2,985
Third Universal Definition of Myocardial Infarction
Thygesen, K., Alpert, J. S., Jaffe, A. S., Simoons, M. L., Chaitman, B. R., White, H. D., & For the Universal Definition of MI, W. G. J. E. (2012) · Global Heart · doi:10.1016/j.gheart.2012.08.001 · Cited by 544
Association of Race and Sex With Risk of Incident Acute Coronary Heart Disease Events
Safford, M. M., Brown, T. M., Muntner, P. M., Durant, R. W., Glasser, S., Halanych, J. H., Shikany, J. M., Prineas, R. J., Samdarshi, T., Bittner, V. A., et al. (2012) · JAMA · doi:10.1001/jama.2012.14306 · Cited by 316
Chin, C. W. L., Shah, A. S. V., McAllister, D. A., Joanna Cowell, S., Alam, S., Langrish, J. P., Strachan, F. E., Hunter, A. L., Maria Choy, A., Lang, C. C., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu189 · Cited by 233
Self-citationUnstable Angina: Is It Time for a Requiem?
Braunwald, E., & Morrow, D. A. (2013) · Circulation · doi:10.1161/circulationaha.113.001258 · Cited by 226
Metadata
- Authors
- Mills, N. L.
- Venue
- JAMA
- Publisher
- American Medical Association (AMA)
- Published
- 2011-03-23
- Volume
- 305
- Issue
- 12
- Pages
- 1210
- ISSN
- 0002-9955 (ISSN-L)
- 0098-7484
- OpenAlex
- W2113883406
- Cited by
- 315
- References
- 1
- FWCI
- 29.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation of a Sensitive Troponin I Assay and Risk of Recurrent Myocardial Infarction and Death in Patients With Suspected Acute Coronary Syndrome. https://app.cochat.ai/papers/10.1001/jama.2011.338
- The paper
- Mills, N. L. (2011). Implementation of a Sensitive Troponin I Assay and Risk of Recurrent Myocardial Infarction and Death in Patients With Suspected Acute Coronary Syndrome. JAMA. https://doi.org/10.1001/jama.2011.338
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.